This is a
1. Start the add mode on the Z-Wave controller. See the controller’s manual.
2. Remove both magnets from Strips. Strips blinks twice to confirm the command and successful addition.
3. A long LED blink indicates that the add process was successful
4. The Z-Wave controller application should now allow you to monitor your Strips sensor status.
5. Move the squared magnet as shown in the picture . Check that the Z-Wave system indicates the status correctly
Strips by Sensative is an ultra-thin magnetic sensor designed to monitor windows and doors for your safety. It´s so thin that it can be mounted invisibly in the tiny gap between the frame and the door or window.
It is as easy to mount as a sticker using Strips"s adhesive tape.
Strips is Z-Wave plus compliant and can be used with any existing Z-Wave smarthome systems.
Reset to factory default | 1. Place the round magnet at the rounded edge of Strips. 2. When the LED blinks, move the magnet away. Repeat 3 times in total within 10 seconds. 3. On the 3rd repetition, leave the magnet at the rounded edge for 10s. 4. A long LED signal indicates success. |
Inclusion | 1. Remove both magnets from Strips. Strips blinks twice to confirm the command and successful addition. 2. A long LED blink indicates that the add process was successful 3. The Z-Wave controller application should now allow you to monitor your Strips sensor status. 4. Move the squared magnet as shown in the picture . Check that the Z-Wave system indicates the status correctly 6. If the Z-Wave system do not respond, it may be needed to change Strips’ notification type. Manual add: 1. Set the controller to add mode (See your controller’s manual).
2. Place the round magnet at the rounded edge of Strips. When the LED blinks, move the magnet away. Repeat 3 times in total within 10 seconds.
3. A long LED blink indicates that the add process was successful. |
Exclusion | Place the round magnet at the rounded edge of Strips. When the LED blinks, move the magnet away. Repeat 3 times in total within 10 seconds. A long LED blink indicates that the remove process was successful. |
NIF | XXXNIF |
Wakeup | Wake up Strips manually for Z-Wave communication: 1. Place the round magnet at the rounded edge of Strips. 2. When the LED blinks, move the magnet away. 3. Repeat 3 times in total within 10 seconds. |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Z-Wave Plus Lifeline |
User can use this configuration parameter to change the notification type compatible with their gatewaycontroller. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Binary Sensor report |
1 | Notification report |
2 | Basic report |
LED On during specific event detected (ex. door opened) else if the parameter value is 0, LED will be turned OFF for the specific event detected. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Specific event indication (ex. door opened) Off |
1 | On |
Dimensions | 195 x 15 x 3 mm |
Weight | 13 gr |
Hardware Platform | ZM5101 |
EAN | 7350088520017 |
Battery Type | 1 * built in LiMnO2 |
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Z-Wave Version | 6.51.06 |
Certification ID | ZC10-16045049 |
Z-Wave Product Id | 0x019A.0x0003.0x0003 |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |