This is a
Pressing the button (3) for one second includes and excludes the device. The smoke sensor is powered either by an internal battery or an optional external integrated power supply. It supports secure communication and will, without further configuration, notify other smoke sensors and sirens of the same type when an alarm occurs.
This product combines a certified stand-alone smoke detector with an insertable Z-Wave module. The smoke detector is certified by the VdS and DIN EN 14604 and satisfies all legal requirements. The smokebox is made of steel and antistatic plastic.
A button on the device can be used to test the smokebox, the electronics and the battery. In addition the device has an integrated test functionality to make manual tests with Aerosol unnecessary. The battery warning gets send for at least 30 days. During this time the smoke sensor stays fully functional.
The Z-Wave radio module enables the device to send smoke-alarms to the connected central Z-Wave controller. The smoke sensor can also be used as Z-Wave siren; for that the Z-Wave controller sends an on or off command to the siren. The radio module uses either the smoke sensors integrated 9V battery or can be powered by an external 12V power supply.
According to the VdS 3515 (smoke sensors with radio communication) this device will relay all alarms to all other smoke sensors (004001) in the Z-Wave network to create a house-wide alarm. This connection of the smoke sensors is fully automatical and needs no further configuration. The smoke sensors and the controller communicate via an secure protocol to prevent manipulation.
Please refer to the installation guide of the smoke sensor for information about how and where the smoke sensor should be installed. The installation guide complies with the norm DIN EN 14676.
Please follow the recommendations about amount as position of the sensor in your home as given above. Avoid to place the sensor into the angle of walls, prefer positions in the middle of the room.
In case smoke is detected by the smoke detector the device will sound, the red LED will blink and the wireless module will issue a Z-Wave alarm command to the main controller and other associated devices. A low battery will be indicated on short siren noise plus the Z-Wave controller will be informed using Battery Low warning commands.
Note: All communication of the wireless module is performed with application level security if the device was included securely and all communication partners support secure communication as well. In case a non-secure device is associated for switching on smoke alarm, the smoke detector will detect this and change its communication styla with this very device to non-secure. This process happens one time and will take about 20 seconds. This delay will happen on first communication only.The siren can be used for other alarm indication. For this reason the device will be shown at Graphical user interface as a simple on/off switch. Turning on this switch start the siren, turning it off will stop the noise. The generic siren alarm has a different acoustic pattern than the permanent sound caused by smoke. The configuration parameters 1 and 2 define the style of the sound.
Automatic radio meshing of the smoke sensorThanks to Z-Wave the smoke sensor can communicate fully automatic. In case of an alarm (smoke or battery) the device will send a notification to all other smoke sensors in the network. The receiving smoke sensor transmit the alarm to other smoke sensors until all smoke sensors have received the alarm.
It is possible to wirelessly turn off the siren on all repeating smoke detectors but not on the detector that originally sent the alarm. You must find and remove the reason for the smoke detector to buzz.
Please note that this meshing is not recommended for networks with more than 3 smoke detectors. In this case please control theme using a central controller and turn off the meshing function by setting configuration parameter 5 and 6.
Reset to factory default | Press the button on the bottom of the device for at least 10 seconds |
Inclusion | A single click on the button (3) includes the device. If the button is pressed for at least 2 seconds the inclusion will be done without the (Security Command Class ). |
Exclusion | A single click on the button will exclude the device. |
NIF | A simple click on the button (3) sends a NIF. |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | Press the Button 2x short to confirm the update. |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 4 | Lifeline |
2 | 4 | Alarm Reports |
3 | 4 | Switching Command when Alarm |
The additional siren is creating a different acoustic signal differentiate from the smoke alarm. This sound is partly on and partly off. This parameter defines the total length of the interval in seconds. Size: 2 Byte, Default Value: 10
Setting | Description |
---|---|
03 - 127 | seconds |
The additional siren is creating a different acoustic signal differentiate from the smoke alarm. This sound is partly on and partly off. This parameter defines the total length of the sound versus silence within this interval. Size: 1 Byte, Default Value: 08
Setting | Description |
---|---|
03 - 127 | seconds |
Size: 1 Byte, Default Value: 99
Setting | Description |
---|---|
00 - 99 | Command Value |
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
00 - 99 | Command Value |
This smoke detector can automatically inform other smoke detectors of same type about smoke alarms. They will then also turn on the siren. This function is a requirement of wireless networked smoke detectors Size: 1 Byte, Default Value: 01
Setting | Description |
---|---|
00 | inactive |
01 | active (default) |
This smoke detector can automatically inform other smoke detectors of same type about battery alarms. They will then also turn on the siren. This function is a requirement of wireless networked smoke detectors. Size: 1 Byte, Default Value: 01
Setting | Description |
---|---|
00 | inactive |
01 | active (default) |
Dimensions | 0.1009100x0.0400000x0.1009100 mm |
Weight | 107 gr |
Hardware Platform | ZM5202 |
EAN | 4251295701073 |
IP Class | IP 20 |
Battery Type | 1 * 9V Block |
Firmware Version | 01.00 |
Z-Wave Version | 04.05 |
Certification ID | ZC10-16125371 |
Z-Wave Product Id | 0x0154.0x0100.0x0201 |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |