This is a
Press once TriSensors Action Button. If it is the first installation, the yellow LED will keep solid until whole network processing is complete. If successful, the LED will flash white -> green -> white -> green, after 2 seconds finished. If failed, the yellow LED lasts for 30 seconds, then the green LED flashes once.If it is the S2 encryption network, please enter the first 5 digits of DSK.
TriSensor can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. If PIR motion sensor is triggered, the TriSensor will send a Basic set to associated devices.The PIR motion sensor will then become inactive. If no PIR motion is triggered after the PIR interval time (configurable), the TriSensor will send Basic Set to the associated nodes.
Reset to factory default | 1. Power up the device. 2. Press and hold the button for 15s until Red Led is blinking,then release the buttonNote: Please use this procedure only when the network primary controller is missing or otherwise inoperable. |
Inclusion | Press once TriSensors Action Button. If it is the first installation, the yellow LED will keep solid until whole network processing is complete. If successful, the LED will flash white -> green -> white -> green, after 2 seconds finished. If failed, the yellow LED lasts for 30 seconds, then the green LED flashes once.If it is the S2 encryption network, please enter the first 5 digits of DSK. |
Exclusion | Press once TriSensors Action Button, the Purple LED will keep solid until whole network processing is complete. If the exclusion is successful, the LED will flash white -> green ->white -> greenand then LED will pulse a blue. If failed, the yellow LED lasts for 30 seconds, then the green LED flashes once. |
NIF | XXXNIF |
Wakeup | Press and hold the button at least 2s until Red Led is on and then release the button,device will send wakeup notification to controller if device is in a Z-Wave network. |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Group 1 is lifeline group; all nodes which associated in this group will receive the messages sent by device through lifeline. Command Class:COMMAND_CLASS_NOTIFICATION COMMAND_CLASS_SENSOR_BINARYCOMMAND_CLASS_SENSOR_MULTILEVEL COMMAND_CLASS_BATTERY COMMAND_CLASS_DEVICE_RESET_LOCALLY Command :NOTIFICATION_REPORT SENSOR_BINARY_REPORT SENSOR_MULTILEVEL_REPORT BATTERY_REPORT DEVICE_RESET_LOCALLY_NOTIFICATION |
2 | 5 | Group 2 is controlling group, all nodes associated in this group will be controlled through BASIC_SET command by the device when device detects a movement event. Basic Set Value is decided by Configuration Parameter 6.Command Class:COMMAND_CLASS_BASIC (Home Security) Command :BASIC_SET |
3 | 5 | Group 3 is controlling group, all nodes associated in this group will be controlled through BASIC_SET command by the device when device detects an ambient temperature alarm (Decided by Configuration Parameter 7).Command Class:COMMAND_CLASS_BASIC (Temperature) Command :BASIC_SET |
This parameter is configured the delay time before PIR sensor can be triggered again to reset motion timeout counter. Value = 0 will disable PIR sensor from triggering until motion timeout has finished. Size: 2 Byte, Default Value: 30
Setting | Description |
---|---|
0 - 32767 | Value = 0 will disable PIR sensor from triggering until motion timeout has finished. |
This parameter is configured the Led light on disable or enable. 1Enable Led Blink when device detects a motion event.0Disable Led Blink. This configuration is not affect inclusion, exclusion and reset. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 - 1 | 1Enable Led Blink when device detects a motion event. 0Disable Led Blink. This configuration is not affect inclusion, exclusion and reset. |
This configuration defines the calibrated scale for ambient light intensity. Because the method and position that the sensor mounted and the cover of sensor will bring measurement error, user can get more real light intensity by this parameter setting. User should run the steps as blows for calibrating1)Set this parameter value to default (Assumes the sensor has been added in a Z-Wave Network).2)Place a digital luxmeter close to sensor and keep the same direction, monitor the light intensity value (Vm) which report to controller and record it. The same time user should record the value (Vs) of luxmeter.3)The scale calibration formula: k = Vm / Vs.4)The value of k is then multiplied by 1024 and rounded to the nearest whole number.5)Set the value getting in to this parameter, calibrate finished.For example, Vm = 300, Vs = 2600, then k = 2600 / 300 = 8.6667k = 8.6667 * 1024 = 8874.78875The parameter should be set to 8875. Size: 2 Byte, Default Value: 1024
Setting | Description |
---|---|
1 - 32767 | This configuration defines the calibrated scale for ambient light intensity. Because the method and position that the sensor mounted and the cover of sensor will bring measurement error, user can get more real light intensity by this parameter setting. |
0Disable. 1Red.2Green.3Blue.4Yellow.5Pink.6Cyan.7Purple.8Orange. Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 - 8 | 0Disable.1Red. 2Green. 3Blue. 4Yellow. 5Pink. 6Cyan. 7Purple. 8Orange. |
0Disable. 1Red.2 Green.3Blue.4Yellow.5Pink.6Cyan.7Purple.8Orange. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 8 | 0Disable.1Red. 2 Green. 3Blue. 4Yellow. 5Pink. 6Cyan. 7Purple. 8Orange. |
0Disable. 1Red.2 Green.3Blue.4Yellow.5Pink.6Cyan.7Purple.8Orange. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 8 | 0Disable.1Red. 2 Green. 3Blue. 4Yellow. 5Pink. 6Cyan. 7Purple. 8Orange. |
0Disable. 1Red.2 Green.3Blue.4Yellow.5Pink.6Cyan.7Purple.8Orange. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 8 | 0Disable.1Red. 2 Green. 3Blue. 4Yellow. 5Pink. 6Cyan. 7Purple. 8Orange. |
0Disable. 1Red.2 Green.3Blue.4Yellow.5Pink.6Cyan.7Purple.8Orange. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 8 | 0Disable.1Red. 2 Green. 3Blue. 4Yellow. 5Pink. 6Cyan. 7Purple. 8Orange. |
This parameter is configured the time to clear motion event after a motion event detected. Time to motion clear, the device will send a clear event report to controller and sendBASIC_SET= 0x00 to nodes associated in group 2. Unit: Second. Size: 2 Byte, Default Value: 240
Setting | Description |
---|---|
1 - 32767 | Time to motion clear, the device will send a clear event report to controller and sendBASIC_SET = 0x00 to nodes associated in group 2. Unit: Second. |
Configure temperature sensor scale type, Temperature to report in Celsius or Fahrenheit. 0Celsius (C).1Fahrenheit (F). Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | 0Celsius (C). 1Fahrenheit (F). |
Change threshold value for change in temperature to induce an automatic report for temperature sensor. Scale is identical setting in Parameter No.20.Setting of value 20 can be a change of -2.0 or +2.0 (C or F depending on Parameter No.20) to induce automatic report or setting a value of 2 will be a change of 0.2(C or F). Size: 2 Byte, Default Value: 20
Setting | Description |
---|---|
0 - 250 | Scale is identical setting in Parameter No.20. Setting of value 20 can be a change of -2.0 or +2.0 (C or F depending on Parameter No.20) to induce automatic report or setting a value of 2 will be a change of 0.2(C or F). |
Change threshold value for change in light sensor to induce an automatic report for temperature sensor. Scale: Lux. Size: 2 Byte, Default Value: 100
Setting | Description |
---|---|
0 - 10000 | Scale: Lux. |
This parameter is configured the time interval for temperature sensor report. This value is larger, the battery life is longer. And the temperature value changed is not obvious.Unit: Second. Size: 2 Byte, Default Value: 3600
Setting | Description |
---|---|
1 - 32767 | Unit: Second. |
This parameter is configured the time interval for light sensor report. This value is larger, the battery life is longer. And the light intensity changed is not obvious.Unit: Second. Size: 2 Byte, Default Value: 3600
Setting | Description |
---|---|
1 - 32767 | Unit: Second. |
This parameter is configured the sensitivity that motion detect. 0PIR sensor disabled.1Lowest sensitivity. 11Highest sensitivity. Size: 1 Byte, Default Value: 11
Setting | Description |
---|---|
0 - 11 | 0PIR sensor disabled. 1Lowest sensitivity. 11Highest sensitivity. |
The current measuring temperature value can be add and minus a value by this setting. The scale can be decided by Parameter Number 20.Temperature Offset Value = [Value] * 0.1(Celsius / Fahrenheit) Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
-200 - 200 | Temperature Offset Value = [Value] * 0.1(Celsius / Fahrenheit) |
The current measuring light intensity value can be add and minus a value by this setting. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
-1000 - 1000 | Scale: Lux. |
0 Disable sensor binary report when motion event is detected or cleared. 1 Enable sensor binary report when motion event is detected or cleared. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | 0 Disable sensor binary report when motion event is detected or cleared. 1 Enable sensor binary report when motion event is detected or cleared. |
This parameter is configured the enabled or disabled send BASIC_SET command to nodes that associated in group 2 and group 3.0Disabled All Group Basic Set Command1Enabled Group 2 Basic Set Command, Group 3 Basic Set Command is disabled. 2Enabled Group 3 Basic Set Command, Group 2 Basic Set Command is disabled. 3Enabled Group 2 and Group 3 Basic Set Command. Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
0 - 3 | 0Disabled All Group Basic Set Command 1Enabled Group 2 Basic Set Command, Group 3 Basic Set Command is disabled. 2Enabled Group 3 Basic Set Command, Group 2 Basic Set Command is disabled. 3Enabled Group 2 and Group 3 Basic Set Command. |
0Send BASIC_SET = 0xFF to devices associated in Group 2 when motion event is triggered, send BASIC_SET = 0x00 to devices associated in group 2 when motion event is cleared.1 Send BASIC_SET = 0x00 to devices associated in Group 2 when motion event is triggered, send BASIC_SET = 0xFF to devices associated in group 2 when motion event is cleared.2Send BASIC_SET = 0xFF to devices associated in Group 2 when motion event is triggered.3Send BASIC_SET = 0x00 to devices associated in Group 2 when motion event is triggered.4Send BASIC_SET = 0x00 to devices associated in Group 2 when motion event is cleared. 5Send BASIC_SET = 0xFF to devices associated in Group 2 when motion event is cleared. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 5 | 0Send BASIC_SET = 0xFF to devices associated in Group 2 when motion event is triggered, send BASIC_SET = 0x00 to devices associated in group 2 when motion event is cleared. 1 Send BASIC_SET = 0x00 to devices associated in Group 2 when motion event is triggered, send BASIC_SET = 0xFF to devices associated in group 2 when motion event is cleared. 2Send BASIC_SET = 0xFF to devices associated in Group 2 when motion event is triggered. 3Send BASIC_SET = 0x00 to devices associated in Group 2 when motion event is triggered. 4Send BASIC_SET = 0x00 to devices associated in Group 2 when motion event is cleared.5Send BASIC_SET = 0xFF to devices associated in Group 2 when motion event is cleared. |
This parameter is configured the threshold value that alarm level for temperature. When the current ambient temperature value is larger than this configuration value, device will send a BASIC_SET = 0xFF to nodes associated in group 3. If current temperature value is less than this value, device will send a BASIC_SET = 0x00 to nodes associated in group 3.Value = [Value]0.1(Celsius / Fahrenheit) Size: 2 Byte, Default Value: 239
Setting | Description |
---|---|
-400 - 850 | Value = [Value]0.1(Celsius / Fahrenheit) |
Hardware Platform | ZM5101 |
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Firmware Version | HW: 17 FW: 2.07:01.01 |
Z-Wave Version | 6.71.01 |
Certification ID | ZC10-18046087 |
Z-Wave Product Id | 0x0371.0x0002.0x0005 |
Color | White |
Sensors | Air TemperatureLuminanceMotion/No Motion (Binary) |
Supported Notification Types | Home Security |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |