Quickstart

This is a secure Notification Sensor for XXXQFrequencyName. To run this device please make sure the internal battery is fully charged. To add this device to your network execute the following action:
Press once TriSensors Action Button. If it is the first installation, the yellow LED will keep solid until whole network processing is complete. If successful, the LED will flash white -> green -> white -> green, after 2 seconds finished. If failed, the yellow LED lasts for 30 seconds, then the green LED flashes once.If it is the S2 encryption network, please enter the first 5 digits of DSK.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

TriSensor can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. If PIR motion sensor is triggered, the TriSensor will send a Basic set to associated devices.The PIR motion sensor will then become inactive. If no PIR motion is triggered after the PIR interval time (configurable), the TriSensor will send Basic Set to the associated nodes.

Reset to factory default 1. Power up the device. 2. Press and hold the button for 15s until Red Led is blinking,then release the buttonNote: Please use this procedure only when the network primary controller is missing or otherwise inoperable.
Inclusion Press once TriSensors Action Button. If it is the first installation, the yellow LED will keep solid until whole network processing is complete. If successful, the LED will flash white -> green -> white -> green, after 2 seconds finished. If failed, the yellow LED lasts for 30 seconds, then the green LED flashes once.If it is the S2 encryption network, please enter the first 5 digits of DSK.
Exclusion Press once TriSensors Action Button, the Purple LED will keep solid until whole network processing is complete. If the exclusion is successful, the LED will flash white -> green ->white -> greenand then LED will pulse a blue. If failed, the yellow LED lasts for 30 seconds, then the green LED flashes once.
NIF XXXNIF
Wakeup Press and hold the button at least 2s until Red Led is on and then release the button,device will send wakeup notification to controller if device is in a Z-Wave network.
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Group 1 is lifeline group; all nodes which associated in this group will receive the messages sent by device through lifeline. Command Class:COMMAND_CLASS_NOTIFICATION COMMAND_CLASS_SENSOR_BINARYCOMMAND_CLASS_SENSOR_MULTILEVEL COMMAND_CLASS_BATTERY COMMAND_CLASS_DEVICE_RESET_LOCALLY Command :NOTIFICATION_REPORT SENSOR_BINARY_REPORT SENSOR_MULTILEVEL_REPORT BATTERY_REPORT DEVICE_RESET_LOCALLY_NOTIFICATION
2 5 Group 2 is controlling group, all nodes associated in this group will be controlled through BASIC_SET command by the device when device detects a movement event. Basic Set Value is decided by Configuration Parameter 6.Command Class:COMMAND_CLASS_BASIC (Home Security) Command :BASIC_SET
3 5 Group 3 is controlling group, all nodes associated in this group will be controlled through BASIC_SET command by the device when device detects an ambient temperature alarm (Decided by Configuration Parameter 7).Command Class:COMMAND_CLASS_BASIC (Temperature) Command :BASIC_SET

Configuration Parameters

Parameter 1: Motion Retrigger Time

This parameter is configured the delay time before PIR sensor can be triggered again to reset motion timeout counter. Value = 0 will disable PIR sensor from triggering until motion timeout has finished.
Size: 2 Byte, Default Value: 30

Setting Description
0 - 32767 Value = 0 will disable PIR sensor from triggering until motion timeout has finished.

Parameter 10: Led Indicate Disable

This parameter is configured the Led light on disable or enable. 1Enable Led Blink when device detects a motion event.0Disable Led Blink. This configuration is not affect inclusion, exclusion and reset.
Size: 1 Byte, Default Value: 1

Setting Description
0 - 1 1Enable Led Blink when device detects a motion event. 0Disable Led Blink. This configuration is not affect inclusion, exclusion and reset.

Parameter 100: Light Sensor Calibrated Coefficient

This configuration defines the calibrated scale for ambient light intensity. Because the method and position that the sensor mounted and the cover of sensor will bring measurement error, user can get more real light intensity by this parameter setting. User should run the steps as blows for calibrating1)Set this parameter value to default (Assumes the sensor has been added in a Z-Wave Network).2)Place a digital luxmeter close to sensor and keep the same direction, monitor the light intensity value (Vm) which report to controller and record it. The same time user should record the value (Vs) of luxmeter.3)The scale calibration formula: k = Vm / Vs.4)The value of k is then multiplied by 1024 and rounded to the nearest whole number.5)Set the value getting in to this parameter, calibrate finished.For example, Vm = 300, Vs = 2600, then k = 2600 / 300 = 8.6667k = 8.6667 * 1024 = 8874.78875The parameter should be set to 8875.
Size: 2 Byte, Default Value: 1024

Setting Description
1 - 32767 This configuration defines the calibrated scale for ambient light intensity. Because the method and position that the sensor mounted and the cover of sensor will bring measurement error, user can get more real light intensity by this parameter setting.

Parameter 11: Led Color For Motion EventReport

0Disable. 1Red.2Green.3Blue.4Yellow.5Pink.6Cyan.7Purple.8Orange.
Size: 1 Byte, Default Value: 2

Setting Description
0 - 8 0Disable.1Red. 2Green. 3Blue. 4Yellow. 5Pink. 6Cyan. 7Purple. 8Orange.

Parameter 12: Led Color For Temperature SensorReport

0Disable. 1Red.2 Green.3Blue.4Yellow.5Pink.6Cyan.7Purple.8Orange.
Size: 1 Byte, Default Value: 0

Setting Description
0 - 8 0Disable.1Red. 2 Green. 3Blue. 4Yellow. 5Pink. 6Cyan. 7Purple. 8Orange.

Parameter 13: Led Color For Light Sensor Report

0Disable. 1Red.2 Green.3Blue.4Yellow.5Pink.6Cyan.7Purple.8Orange.
Size: 1 Byte, Default Value: 0

Setting Description
0 - 8 0Disable.1Red. 2 Green. 3Blue. 4Yellow. 5Pink. 6Cyan. 7Purple. 8Orange.

Parameter 14: Led Color For Battery Report

0Disable. 1Red.2 Green.3Blue.4Yellow.5Pink.6Cyan.7Purple.8Orange.
Size: 1 Byte, Default Value: 0

Setting Description
0 - 8 0Disable.1Red. 2 Green. 3Blue. 4Yellow. 5Pink. 6Cyan. 7Purple. 8Orange.

Parameter 15: Led Color For Wakeup NotificationReport

0Disable. 1Red.2 Green.3Blue.4Yellow.5Pink.6Cyan.7Purple.8Orange.
Size: 1 Byte, Default Value: 0

Setting Description
0 - 8 0Disable.1Red. 2 Green. 3Blue. 4Yellow. 5Pink. 6Cyan. 7Purple. 8Orange.

Parameter 2: Motion Clear Time

This parameter is configured the time to clear motion event after a motion event detected. Time to motion clear, the device will send a clear event report to controller and sendBASIC_SET= 0x00 to nodes associated in group 2. Unit: Second.
Size: 2 Byte, Default Value: 240

Setting Description
1 - 32767 Time to motion clear, the device will send a clear event report to controller and sendBASIC_SET = 0x00 to nodes associated in group 2. Unit: Second.

Parameter 20: Temperature Scale Setting

Configure temperature sensor scale type, Temperature to report in Celsius or Fahrenheit. 0Celsius (C).1Fahrenheit (F).
Size: 1 Byte, Default Value: 0

Setting Description
0 - 1 0Celsius (C). 1Fahrenheit (F).

Parameter 21: Temperature Threshold Value toReport

Change threshold value for change in temperature to induce an automatic report for temperature sensor. Scale is identical setting in Parameter No.20.Setting of value 20 can be a change of -2.0 or +2.0 (C or F depending on Parameter No.20) to induce automatic report or setting a value of 2 will be a change of 0.2(C or F).
Size: 2 Byte, Default Value: 20

Setting Description
0 - 250 Scale is identical setting in Parameter No.20. Setting of value 20 can be a change of -2.0 or +2.0 (C or F depending on Parameter No.20) to induce automatic report or setting a value of 2 will be a change of 0.2(C or F).

Parameter 22: Light intensity Threshold Value to Report

Change threshold value for change in light sensor to induce an automatic report for temperature sensor. Scale: Lux.
Size: 2 Byte, Default Value: 100

Setting Description
0 - 10000 Scale: Lux.

Parameter 23: Temperature Sensor ReportInterval

This parameter is configured the time interval for temperature sensor report. This value is larger, the battery life is longer. And the temperature value changed is not obvious.Unit: Second.
Size: 2 Byte, Default Value: 3600

Setting Description
1 - 32767 Unit: Second.

Parameter 24: Light Sensor Report Interval

This parameter is configured the time interval for light sensor report. This value is larger, the battery life is longer. And the light intensity changed is not obvious.Unit: Second.
Size: 2 Byte, Default Value: 3600

Setting Description
1 - 32767 Unit: Second.

Parameter 3: Motion Sensitivity

This parameter is configured the sensitivity that motion detect. 0PIR sensor disabled.1Lowest sensitivity. 11Highest sensitivity.
Size: 1 Byte, Default Value: 11

Setting Description
0 - 11 0PIR sensor disabled. 1Lowest sensitivity. 11Highest sensitivity.

Parameter 30: Temperature Offset Value

The current measuring temperature value can be add and minus a value by this setting. The scale can be decided by Parameter Number 20.Temperature Offset Value = [Value] * 0.1(Celsius / Fahrenheit)
Size: 2 Byte, Default Value: 0

Setting Description
-200 - 200 Temperature Offset Value = [Value] * 0.1(Celsius / Fahrenheit)

Parameter 31: Light Intensity Offset Value

The current measuring light intensity value can be add and minus a value by this setting.
Size: 2 Byte, Default Value: 0

Setting Description
-1000 - 1000 Scale: Lux.

Parameter 4: Binary Sensor Report Enable

0 Disable sensor binary report when motion event is detected or cleared. 1 Enable sensor binary report when motion event is detected or cleared.
Size: 1 Byte, Default Value: 0

Setting Description
0 - 1 0 Disable sensor binary report when motion event is detected or cleared. 1 Enable sensor binary report when motion event is detected or cleared.

Parameter 5: Disable BASIC_SET to Associatednodes

This parameter is configured the enabled or disabled send BASIC_SET command to nodes that associated in group 2 and group 3.0Disabled All Group Basic Set Command1Enabled Group 2 Basic Set Command, Group 3 Basic Set Command is disabled. 2Enabled Group 3 Basic Set Command, Group 2 Basic Set Command is disabled. 3Enabled Group 2 and Group 3 Basic Set Command.
Size: 1 Byte, Default Value: 3

Setting Description
0 - 3 0Disabled All Group Basic Set Command 1Enabled Group 2 Basic Set Command, Group 3 Basic Set Command is disabled. 2Enabled Group 3 Basic Set Command, Group 2 Basic Set Command is disabled. 3Enabled Group 2 and Group 3 Basic Set Command.

Parameter 6: Basic Set Value Settings for Group 2

0Send BASIC_SET = 0xFF to devices associated in Group 2 when motion event is triggered, send BASIC_SET = 0x00 to devices associated in group 2 when motion event is cleared.1 Send BASIC_SET = 0x00 to devices associated in Group 2 when motion event is triggered, send BASIC_SET = 0xFF to devices associated in group 2 when motion event is cleared.2Send BASIC_SET = 0xFF to devices associated in Group 2 when motion event is triggered.3Send BASIC_SET = 0x00 to devices associated in Group 2 when motion event is triggered.4Send BASIC_SET = 0x00 to devices associated in Group 2 when motion event is cleared. 5Send BASIC_SET = 0xFF to devices associated in Group 2 when motion event is cleared.
Size: 1 Byte, Default Value: 0

Setting Description
0 - 5 0Send BASIC_SET = 0xFF to devices associated in Group 2 when motion event is triggered, send BASIC_SET = 0x00 to devices associated in group 2 when motion event is cleared. 1 Send BASIC_SET = 0x00 to devices associated in Group 2 when motion event is triggered, send BASIC_SET = 0xFF to devices associated in group 2 when motion event is cleared. 2Send BASIC_SET = 0xFF to devices associated in Group 2 when motion event is triggered. 3Send BASIC_SET = 0x00 to devices associated in Group 2 when motion event is triggered. 4Send BASIC_SET = 0x00 to devices associated in Group 2 when motion event is cleared.5Send BASIC_SET = 0xFF to devices associated in Group 2 when motion event is cleared.

Parameter 7: Temperature Alarm Value

This parameter is configured the threshold value that alarm level for temperature. When the current ambient temperature value is larger than this configuration value, device will send a BASIC_SET = 0xFF to nodes associated in group 3. If current temperature value is less than this value, device will send a BASIC_SET = 0x00 to nodes associated in group 3.Value = [Value]0.1(Celsius / Fahrenheit)
Size: 2 Byte, Default Value: 239

Setting Description
-400 - 850 Value = [Value]0.1(Celsius / Fahrenheit)

Technical Data

Hardware Platform ZM5101
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Firmware Version HW: 17 FW: 2.07:01.01
Z-Wave Version 6.71.01
Certification ID ZC10-18046087
Z-Wave Product Id 0x0371.0x0002.0x0005
Color White
Sensors Air TemperatureLuminanceMotion/No Motion (Binary)
Supported Notification Types Home Security
Frequency XXfrequency
Maximum transmission power XXantenna
CEPT (Europe)Notification Sensor