Quickstart

This is a secure Notification Sensor for XXXQFrequencyName. To run this device please make sure the internal battery is fully charged. To add this device to your network execute the following action:
Turn the primary controller of Z-Wave network into inclusion mode, short press the products Z-Wave button that you can find in the back of the product.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

Aeotec MultiSensor 6 looks like a motion sensor and it acts like one too. But its also so much more. Installing this 1 piece of Z-Wave technology is the same as installing 6 pieces of Z-Wave technology. Your home control network will immediately understand motion, temperature, humidity, light, Ultraviolet and Vibration readings wherever MultiSensor installed. Those intelligent readings will equate to intelligence automation. And intelligent automation will give you the perfect, smart home.

Reset to factory default Press and hold the Z-Wave button that you can find in back of the product for 20 seconds and then release. This procedure should only be used when the primary controller is inoperable.
Inclusion Turn the primary controller of Z-Wave network into inclusion mode, short press the products Z-Wave button that you can find in the back of the product.
Exclusion Turn the primary controller of Z-Wave network into exclusion mode, short press the products Z-Wave button that you can find in back of the product.
NIF XXXNIF
Wakeup Pressing the Z-Wave button once will trigger sending the Wake up notification command. If press and hold the Z-Wave button for 3 seconds, the MultiSensor will wake up for 10 minutes.
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 The MultiSensor supports 1 association group. Group 1 is assigned to the Lifeline association group and can add max 5 association nodes.When the PIR motion sensor is triggered, the MultiSensor will send Basic Set (0xFF) to the associated nodes. If no PIR motion is triggered after the PIR interval time (configurable), the MultiSensor will send Basic Set (0x00) to the associated nodes.The automatically reports of temperature, humidity, luminance and ultraviolet (configurable) also can be sent to the associated nodes.

Configuration Parameters

Parameter 100: Set the parameter 101-103 to default values.

Set the parameter 101-103 to default values.
Size: 1 Byte, Default Value: 0

Setting Description
1 Set the parameter 101-103 to default values.

Parameter 101: To set which report would be sent in Report group 1

To set which report would be sent in Report group 1.Note:You can also set all sensor reports to be sent out at the same time. E.g. If you want the batter report and temperature report to be sent out at the same time, you just need to set the configuration value to 33 (1+32).
Size: 4 Byte, Default Value: 241

Setting Description
1 Battery Report is enabled.
16 Ultraviolet Report is enabled.
32 Temperature Report is enabled.
64 Humidity Report is enabled.
128 Luminance Report is enabled.

Parameter 102: To set which report would be sent in Report group 2

To set which report would be sent in Report group 2.Note:You can also set all sensor reports to be sent out at the same time. E.g. If you want the batter report and temperature report to be sent out at the same time, you just need to set the configuration value to 33 (1+32).
Size: 4 Byte, Default Value: 0

Setting Description
1 Battery Report is enabled.
16 Ultraviolet Report is enabled.
32 Temperature Report is enabled.
64 Humidity Report is enabled.
128 Luminance Report is enabled.

Parameter 103: To set which report would be sent in Report group 3

To set which report would be sent in Report group 3.Note:You can also set all sensor reports to be sent out at the same time. E.g. If you want the batter report and temperature report to be sent out at the same time, you just need to set the configuration value to 33 (1+32).
Size: 4 Byte, Default Value: 0

Setting Description
1 Battery Report is enabled.
16 Ultraviolet Report is enabled.
32 Temperature Report is enabled.
64 Humidity Report is enabled.
128 Luminance Report is enabled.

Parameter 111: To set the interval time of sending reports in Report group 1

To set the interval time of sending reports in Report group 1
Size: 4 Byte, Default Value: 3600

Setting Description
5 - 2678400 Available rang is 5 to 2678400 seconds.

Parameter 112: To set the interval time of sending reports in Report group 2

To set the interval time of sending reports in Report group 2
Size: 4 Byte, Default Value: 3600

Setting Description
5 - 2678400 Available rang is 5 to 2678400 seconds.

Parameter 113: To set the interval time of sending reports in Report group 3

To set the interval time of sending reports in Report group 3
Size: 4 Byte, Default Value: 3600

Setting Description
5 - 2678400 Available rang is 5 to 2678400 seconds.

Parameter 2: Enable/Disable waking up for 10 minutes when re-power on (battery mode) the MultiSensor.

Enable/Disable waking up for 10 minutes when re-power on (battery mode) the MultiSensor.
Size: 1 Byte, Default Value: 0

Setting Description
0 Disable
1 Enable.

Parameter 201: Temperature sensor calibration

Temperature sensor calibration.Note:1.High byte is the calibration value. Low byte is the unit (0x01=Celsius, 0x02=Fahrenheit)2.The calibration value (high byte) contains one decimal point. E.g. if the value is set to 20 (0x1401), the calibration value is 2.0(EU/AU version) or if the value is set to 20 (0x1402), the calibration value is 2.0 (US version)3.The calibration value (high byte) = standard value - measure value.E.g.If measure value =25.3 and the standard value = 23.2, so the calibration value= 23.2 - 25.3= -2.1 (0xEB).If the measure value =30.1 and the standard value = 33.2, so the calibration value= 33.2 - 30.1=3.1 (0x1F).
Size: 2 Byte, Default Value: 0

Setting Description
-128 - 127 Available rang is -12.8 to 12.7.

Parameter 202: Humidity sensor calibration

Humidity sensor calibration.The calibration value = standard value - measure value.E.g.If measure value =80RH and the standard value = 75RH, so the calibration value= 75RH80RH= -5RH (0xFB).If the measure value =85RH and the standard value = 90RH, so the calibration value= 90RH85RH=5RH (0x05).
Size: 1 Byte, Default Value: 0

Setting Description
-50 - 50 Available rang is -50RH to 50RH.

Parameter 203: Luminance sensor calibration

Luminance sensor calibration.The calibration value = standard value - measure value.E.g.If measure value =800Lux and the standard value = 750Lux, so the calibration value= 750800= -50 (0xFFCE).If the measure value =850Lux and the standard value = 900Lux, so the calibration value= 900850=50 (0x0032)
Size: 2 Byte, Default Value: 0

Setting Description
-1000 - 1000 Available rang is -1000Lux to 1000Lux.

Parameter 204: Ultraviolet sensor calibration

Ultraviolet sensor calibration.The calibration value = standard value - measure value.E.g.If measure value =9 and the standard value = 8, so the calibration value= 89= -1 (0xFE).If the measure value =7 and the standard value = 9, so the calibration value= 97=2 (0x02).
Size: 1 Byte, Default Value: 0

Setting Description
-10 - 10 Available rang is -10 to 10.

Parameter 252: Enable/disable all configuration parameters to be locked

Enable/disable all configuration parameters to be locked.
Size: 1 Byte, Default Value: 0

Setting Description
0 Disable
1 Enable.

Parameter 255: Reset to factory defaults.

Reset to factory defaults.
Size: 4 Byte, Default Value: 0

Setting Description
1 Reset all configuration parameters to factory defaults.
1431655765 Reset the product to factory defaults.

Parameter 3: Set the PIR time.

The default PIR time is 4 minutes. The Multisensor will send BASIC SET CC (0x00) to the associated nodes if no motion is triggered again in 4 minutes.
Size: 2 Byte, Default Value: 240

Setting Description
10 - 3600 The range of PIR time is 10 to 3600.

Parameter 39: Configure the default low battery value.

Configure the default low battery value. When the current battery level is lower than this value, it will send out the low battery alarm.
Size: 1 Byte, Default Value: 20

Setting Description
10 - 50 Available rang is 10% to 50%.

Parameter 4: Set the sensitivity of the motion sensor.

This parameter changes the sensitivity level of the motion detector.
Size: 1 Byte, Default Value: 5

Setting Description
0 Minimum Sensitivity
1 Sensitivity Level 1 of 6
2 Sensitivity Level 2 of 6
3 Sensitivity Level 3 of 6
4 Sensitivity Level 5 of 6
5 Maximum Sensitivity

Parameter 40: Enable/disable the selective reporting only when measurements reach a certain threshold or percentage

Enable/disable the selective reporting only when measurements reach a certain threshold or percentage. This is used to reduce network traffic.Note: If USB power, the Sensor will check the threshold every 10 seconds. If battery power, the Sensor will check the threshold when it is waken up.
Size: 1 Byte, Default Value: 0

Setting Description
0 Disable
1 Enable.

Parameter 41: Threshold change in temperature to induce an automatic report.

Threshold change in temperature to induce an automatic report. Note:1.The unit is Fahrenheit for US version, Celsius for EU/AU version.2.High byte is the threshold value. Low byte is the unit (0x01=Celsius, 0x02=Fahrenheit).3.The threshold value (high byte) contains one decimal point. E.g. if the value is set to 20 (0x001401), the threshold value =2.0(EU/AU version) or if the value is set to 20 (0x001402), the threshold value= 2.0(US version). When the current temperature gap is more then 2.0, which will induce a temperature report to be sent out.
Size: 4 Byte, Default Value: 20

Setting Description
10 - 2120 Available rang of threshold is 1 to 212.

Parameter 42: Threshold change in humidity to induce an automatic report

Threshold change in humidity to induce an automatic report.Note:1.The unit is %.2.The default value is 10, which means that if the current humidity gap is more than 10%, it will send out a humidity report.
Size: 1 Byte, Default Value: 10

Setting Description
1 - 100 Available rang is 1% to 100%.

Parameter 43: Threshold change in luminance to induce an automatic report.

Threshold change in luminance to induce an automatic report.
Size: 2 Byte, Default Value: 100

Setting Description
1 - 30000 Available rang is 1 LUX to 30000 LUX.

Parameter 44: Threshold change in battery level to induce an automatic report.

Threshold change in battery level to induce an automatic report.Note:1.The unit is %.2.The default value is 10, which means that if the current battery level gap is more than 10%, it will send out a battery report.
Size: 1 Byte, Default Value: 10

Setting Description
1 - 100 Available rang is 1% to 100%.

Parameter 45: Threshold change in ultraviolet to induce an automatic report.

Threshold change in ultraviolet to induce an automatic report.
Size: 1 Byte, Default Value: 2

Setting Description
1 - 11 Available rang is 1 to 11.

Parameter 46: Enable/disable to send the alarm report of low temperature

Enable/disable to send the alarm report of low temperature(<-15).Note:If it is enabled, the MultiSensor will send a report of Multi Level Temperature CC to controller when the current temperature is less than -15).
Size: 1 Byte, Default Value: 0

Setting Description
0 Disable
1 Enable.
1 - 30000 Available rang is 1LUX to 30000LUX.

Parameter 48: Enable/disable to send a report when the measurement is more than the upper limit value or less than the lower limit value.

Enable/disable to send a report when the measurement is more than the upper limit value or less than the lower limit value.
Size: 1 Byte, Default Value: 0

Setting Description
0 Disable
1 Enable.

Parameter 49: Set the upper limit value of temperature sensor.

Set the upper limit value of temperature sensor.When the measurement is more than this upper limit, which will trigger to sent out a sensor report.
Size: 4 Byte, Default Value: 824

Setting Description
-400 - 2120 Available rang is -40.0 to 212.0.

Parameter 5: Which command would be sent when the motion sensor triggered.

To set which command would be sent when the motion sensor triggered.
Size: 1 Byte, Default Value: 1

Setting Description
1 Send Basic Set CC
2 Send Sensor Binary Report CC

Parameter 50: Set the lower limit value of temperature sensor.

Set the lower limit value of temperature sensor. When the measurement is less than this lower limit, which will trigger to sent out a sensor report.High byte is the lower limit value.
Size: 4 Byte, Default Value: 320

Setting Description
-400 - 2120 Available rang is -40.0 to 212.0.

Parameter 51: Set the upper limit value of humidity sensor.

Set the upper limit value of humidity sensor. when the measurement is more than this upper limit, which will trigger to sent out a sensor report.
Size: 1 Byte, Default Value: 60

Setting Description
0 - 100 Available rang is 0% to 100%.

Parameter 52: Set the lower limit value of humidity sensor.

Set the lower limit value of humidity sensor. When the measurement is less than this lower limit, which will trigger to sent out a sensor report.
Size: 1 Byte, Default Value: 50

Setting Description
0 - 100 Available rang is 0% to 100%.

Parameter 53: Set the upper limit value of Lighting sensor

Set the upper limit value of Lighting sensor. When the measurement is more than this upper limit, which will trigger to sent out a sensor report.
Size: 1 Byte, Default Value: 1000

Setting Description
0 - 30000 Available rang is 0 to 30000LUX.

Parameter 54: Set the lower limit value of Lighting sensor.

Set the lower limit value of Lighting sensor. When the measurement is less than this lower limit, which will trigger to sent out a sensor report.
Size: 1 Byte, Default Value: 100

Setting Description
0 - 30000 Available rang is 0 to 30000LUX.

Parameter 55: Set the upper limit value of ultraviolet sensor.

Set the upper limit value of ultraviolet sensor. When the measurement is more than this upper limit, which will trigger to sent out a sensor report.
Size: 1 Byte, Default Value: 8

Setting Description
1 - 11 Available rang is 1 to 11.

Parameter 56: Set the lower limit value of ultraviolet sensor.

Set the lower limit value of ultraviolet sensor. When the measurement is less than this upper limit, which will trigger to sent out a sensor report.
Size: 1 Byte, Default Value: 4

Setting Description
1 - 11 Available rang is 1 to 11.

Parameter 57: Set the recover limit value of temperature sensor.

Note:1.When the current measurement <= (Upper limitRecover limit), the upper limit report is enabled and then it would send out a sensor report when the next measurement is more than the upper limit. After that the upper limit report would be disabled again until the measurement <= (Upper limitRecover limit).2.When the current measurement >= (Lower limit + Recover limit), the lower limit report is enabled and then it would send out a sensor report when the next measurement is less than the lower limit. After that the lower limit report would be disabled again until the measurement >= (Lower limit + Recover limit).3.High byte is the recover limit value. Low byte is the unit (0x01=Celsius, 0x02=Fahrenheit).
Size: 2 Byte, Default Value: 20

Setting Description
10 - 255 Available rang is 1.0 to 25.5

Parameter 58: Set the recover limit value of humidity sensor.

Set the recover limit value of humidity sensor.Note:1.When the current measurement <= (Upper limitRecover limit), the upper limit report is enabled and then it would send out a sensor report when the next measurement is more than the upper limit. After that the upper limit report would be disabled again until the measurement <= (Upper limitRecover limit).2.When the current measurement >= (Lower limit + Recover limit), the lower limit report is enabled and then it would send out a sensor report when the next measurement is less than the lower limit. After that the lower limit report would be disabled again until the measurement >= (Lower limit + Recover limit).
Size: 1 Byte, Default Value: 5

Setting Description
1 - 50 Available rang is 1 to 50%

Parameter 59: Set the recover limit value of Lighting sensor.

Set the recover limit value of Lighting sensor.Note:1.When the current measurement <= (Upper limitRecover limit), the upper limit report is enabled and then it would send out a sensor report when the next measurement is more than the upper limit. After that the upper limit report would be disabled again until the measurement <= (Upper limitRecover limit).2.When the current measurement >= (Lower limit + Recover limit), the lower limit report is enabled and then it would send out a sensor report when the next measurement is less than the lower limit. After that the lower limit report would be disabled again until the measurement >= (Lower limit + Recover limit).3.Unit = 10Recover limit (Lux)
Size: 1 Byte, Default Value: 100

Setting Description
1 - 127 Available rang is 10Lux to 1270Lux

Parameter 60: Set the recover limit value of Ultraviolet sensor.

Set the recover limit value of Ultraviolet sensor.Note:1.When the current measurement <= (Upper limitRecover limit), the upper limit report is enabled and then it would send out a sensor report when the next measurement is more than the upper limit. After that the upper limit report would be disabled again until the measurement <= (Upper limitRecover limit).2.When the current measurement >= (Lower limit + Recover limit), the lower limit report is enabled and then it would send out a sensor report when the next measurement is less than the lower limit. After that the lower limit report would be disabled again until the measurement >= (Lower limit + Recover limit).
Size: 1 Byte, Default Value: 2

Setting Description
0 USB power mode
1 - 5 Available rang is 1 to 5.
256 Keep sleep state for Battery power mode
257 Keep awake for 10 minutes for battery power mode.

Parameter 61: Get the out-of-limit state of the Sensors.

Get the out-of-limit state of the Sensors.
Size: 2 Byte, Default Value: 0

Setting Description
1 Temperature sensor is out of the lower limit
2 Humidity sensor is out of the lower limit
4 Luminance sensor is out of the lower limit
8 Ultraviolet sensor is out of the lower limit
16 Temperature sensor is out of the upper limit
32 Humidity sensor is out of the upper limit
64 Luminance sensor is out of the upper limit
128 Ultraviolet sensor is out of the upper limit

Parameter 64: Set the default unit of the automatic temperature report in parameter 101-103.

Set the default unit of the automatic temperature report in parameter 101-103.
Size: 1 Byte, Default Value: 2

Setting Description
1 The unit is Celsius.
2 The unit is Fahrenheit.

Parameter 8: Set the timeout of awake after the Wake Up CC is sent out..

Set the timeout of awake after the Wake Up CC is sent out..
Size: 1 Byte, Default Value: 30

Setting Description
8 - 127 Available rang is 8 to 127 seconds.

Parameter 81: Enable/disable the LED blinking when the PIR is triggered.

Enable/disable the LED blinking when the PIR is triggered.
Size: 1 Byte, Default Value: 0

Setting Description
0 Enable.
1 Disable

Parameter 9: Report the current power mode and the product state for battery power mode

Report the current power mode and the product state for battery power mode.Note: this parameter cannot be used as Set usage.
Size: 2 Byte, Default Value: 0

Setting Description
0 USB power mode
256 Keep sleep state for Battery power mode
257 Keep awake for 10 minutes for battery power mode.

Technical Data

Hardware Platform ZM5101
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Firmware Version HW: 100 FW: 1.10
Z-Wave Version 6.51.10
Certification ID ZC10-17115845
Z-Wave Product Id 0x0086.0x0102.0x0064
Sensors Air TemperatureHumidityLuminanceMotion/No Motion (Binary)Ultraviolet IndexVibration/Shock (Binary)
Supported Notification Types Home Security
IP (Ingress Protection) Rated ok
Firmware Updatable Updatable by Consumer by RF
Frequency XXfrequency
Maximum transmission power XXantenna
U.S. / Canada / MexicoNotification Sensor