This is a
The Secure Key Fob Controller is a 4 button Z-Wave device capable to act both as primary or secondary controller. The four buttons can control other Z-Wave devices such as switches, dimmer and even door locks directly. Various options - configurable by Z-Wave configuration commands - define the actions and the commands used for this control. It is possible to use two sets of buttons (one of on/open/up and one for off/closed/down) or 4 single buttons to control 4 different groups of devices.
The controller also allows triggering scenes in a central controller. Again different modes can be configured to adapt to the various implementations of scenes in different central controllers in the market.
Control options also include special modes like "all on/off" or always controlling the Z-Wave device in proximity to the fob. The device supports secure communication when included with enhanced security option and when communicating to a device also supporting enhanced security option. Otherwise the device will automatically turn into normal communication. to maintain backward compatibility.
Reset to factory default | Enter management mode by push all four buttons together for one second - green led blinks slowly), then hit button 3 followed by keeping button 4 pushed down for 10 seconds. The first five seconds the green LED still blinks followed by a long red, shot green sequence. Once LEDs go off, reset was executed. Please use this procedure only if the device is secondary controller and the primary controller is missing or otherwise inoperable. |
Inclusion | When in factory default push Button 3 (secure) or Button 4 (normal) for one second to enter inclusion mode. The inclusion mode is indicated by a blinking green LED. From second device on you need to enter management mode push all four buttons together for one second - green led blinks slowly), hit button 3 ( enter primary controller functions - green led blinks faster) and then button 1 (secure) or button 2 (normal). |
Exclusion | Enter management mode by push all four buttons together for one second - green led blinks slowly), hit button 3 ( enter primary controller functions - green led blinks faster) and then button 3 again. |
NIF | XXXNIF |
Wakeup | Enter management mode by push all four buttons together for one second - green led blinks slowly), then hit button 2 . |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 10 | Z-Wave Plus Lifeline |
2 | 10 | Control Group A, controlled by button 1 or single clicks of buttons 1 and 3 |
3 | 10 | Control Group B, controlled by button 2 or single clicks of buttons 2 and 4 |
4 | 10 | Control Group C, controlled by button 3 or double clicks of buttons 1 and 3 |
5 | 10 | Control Group D, controlled by button 4 or double clicks of buttons 2 and 4 |
In separate mode button 1 works with group A, button 3 with groups C. Click is On, Hold is dimming Up, Double click is Off, Click-Hold is dimming Down. In pair button 1/3 are Up/Down correspondingly. Click is On/Off, Hold is dimming Up/Down. Single clicks works with group A, double click with group C. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
2 | In pair with double clicks |
0 | seperately |
1 | In pair without double clicks |
This parameter defines the command to be sent to devices of control group A when the related button is pressed Size: 1 Byte, Default Value: 8
Setting | Description |
---|---|
5 | Send Preconfigured Scenes |
7 | Control DoorLock |
8 | Central Scene to Gateway |
0 | Disabled |
1 | Switch On/Off and Dim (send Basic Set and Switch Multilevel) |
2 | Switch On/Off only (send Basic Set) |
3 | Switch All |
4 | Send Scenes |
This parameter defines the command to be sent to devices of control group B when the related button is pressed Size: 1 Byte, Default Value: 8
Setting | Description |
---|---|
4 | Send Scenes |
3 | Switch All |
5 | Send Preconfigured Scenes |
7 | Control DoorLock |
8 | Central Scene to Gateway |
0 | Disabled |
1 | Switch On/Off and Dim (send Basic Set and Switch Multilevel) |
2 | Switch On/Off only (send Basic Set) |
This parameter defines the command to be sent to devices of control group C when the related button is pressed Size: 1 Byte, Default Value: 8
Setting | Description |
---|---|
0 | Disabled |
1 | Switch On/Off and Dim (send Basic Set and Switch Multilevel) |
2 | Switch On/Off only (send Basic Set) |
3 | Switch All |
4 | Send Scenes |
5 | Send Preconfigured Scenes |
7 | Control DoorLock |
8 | Central Scene to Gateway |
This parameter defines the command to be sent to devices of control group D when the related button is pressed Size: 1 Byte, Default Value: 8
Setting | Description |
---|---|
1 | Switch On/Off and Dim (send Basic Set and Switch Multilevel) |
0 | Disabled |
2 | Switch On/Off only (send Basic Set) |
3 | Switch All |
4 | Send Scenes |
5 | Send Preconfigured Scenes |
7 | Control DoorLock |
8 | Central Scene to Gateway |
In separate mode button 2 works with control group B, button 4 with control group D. Click is On, Hold is dimming Up, Double click is Off, Click-Hold is dimming Down. In pair button B/D are Up/Down correspondingly. Click is On/Off, Hold is dimming Up/Down. Single clicks works with group B, double click with group D. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
2 | In pair with double clicks |
1 | In pair without double clicks |
0 | seperately |
Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
1 | Switch off only |
2 | Switch on only |
255 | Switch all on and off |
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
1 | Yes |
0 | No |
Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Wakeup is blocked |
1 | Wakeup is not blocked |
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | No |
1 | To same node as wake up notification |
2 | Broadcast |
Dimensions | 30x55x15 mm |
Weight | 32 gr |
Hardware Platform | ZM5202 |
EAN | 0019962007002 |
Device Type | Remote Control - Simple |
Network Operation | Portable Controller |
Z-Wave Version | 6.51.03 |
Certification ID | ZC10-15050016 |
Z-Wave Product Id | 0x0115.0x0100.0x0103 |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |