After removing the cover push the tamper switch for three seconds until the red LED blinks. Inclusion and Exclusion is confirm when the tamper switch is released at this moment. The same process sends out a NIF. Removing the cover wakes up the device.
This battery operated device combines a temperature sensor with a binary sensor using dry input connectors. Both sensor functions can be used independently. The device has a tampering protection switch that is suited for applications where the dry inputs are used for security related application. The binary sensor is issuing a wireless command whenever the connection is closed or opened. The temperature sensor needs to be polled in order to get its value. The device is IP 20 rated and can be used in dry environments only. The precision of the temperature sensor is in the range of +/- 1 °C
Attention: This is a multi purpose device with the binary sensor as primary and the temperature as secondary function. Depending on the policies used certain simplistic User Interfaces - such as VERA Dashboard - may not show the temperature value but the dry input as binary sensor only.
Please make sure to insert the batteries in the right direction. Don"t mix batteries of different type or vendor. The device can be mounted on every flat and dry surface either using double sided adhesive tape or any type of screws.
The device can be mounted in every location of a room for measuring the temperature. For optimal values it is recommended to mount the sensor at a wall in a hight of 1,50 m above the ground and not directly to a heater.
the binary sensor can be used as a door or window sensor. Therefore you can use a simple two-wire cable.
Reset to factory default | XXXResetDescription |
Inclusion | After removing the cover push the tamper switch for three seconds until the red LED blinks. Inclusion and Exclusion is confirm when the tamper switch is released at this moment. |
Exclusion | After removing the cover push the tamper switch for three seconds until the red LED blinks. Inclusion and Exclusion is confirm when the tamper switch is released at this moment. |
NIF | After removing the cover push the tamperswitch for three seconds until the red LED blinks. Releasing the tamper switch issues a Node Information Frame. |
Wakeup | Removing the cover wakes up the device. |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
2 | 5 | Alarm triggered by Tamper Switch |
1 | 5 | Dry Binary Input close/open |
Resets the device Size: 1 Byte, Default Value: 00
Setting | Description |
---|---|
00 | normal operation |
01 | reset |
Defines the type of command sent when dry input triggers Size: 1 Byte, Default Value: 00
Setting | Description |
---|---|
00 | Alarm Report Type 2 |
01 | Basic On or Off |
Defines ufffcif the sensor is in normal - ufffcwakeup- mode or always on. This ufffcfunction shall be used only for testing ufffcsince its draining the battery very fast Size: 1 Byte, Default Value: 00
Setting | Description |
---|---|
01 | normal mode |
03 | always awake |
Allows to calibrate the temperature measurement function Size: 1 Byte, Default Value: 00
Setting | Description |
---|---|
00 | 0 K |
ce - 32 | Temperature Offset in K |
Dimensions | 0.0030000x0.0050000x0.0010000 mm |
Weight | 20 gr |
Hardware Platform | ZM3102 |
EAN | 0696859123351 |
Battery Type | 2 * AAA |
Device Type | Routing Binary Sensor |
Generic Device Class | Binary Sensor |
Specific Device Class | Binary Sensor |
Firmware Version | 00.27 |
Z-Wave Version | 02.61 |
Certification ID | ZC08-12120004 |
Z-Wave Product Id | 0097.1182.4501 |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |