Quickstart

This is a secure Binary Power Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply. Plug in and press the button 3 times.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

WiDom Smart Plug is able to detect overvoltage and/or overcurrent events and indicate them through a multicolor LED. Furthermore, it protects appliances from eventual overload. A very innovative design, which integrates a complex system that allows a precise energy consumption monitoring. The integration of these features in its very small size product, make it unique on the market.
The device is equipped with contact protection technology (Zero Crossing) which reduces the electrical stress on the relay contacts and ensures a longer life. The open / closed switching of the device always occur when the instantaneous value of voltage is 0.
It operates in any Z-Wave network with other Z-Wave/Z-Wave Plus certified devices and controllers from any other manufacturer. As a constantly powered node, WiDom Smart Plug will act as repeater regardless of the vendor in order to increase the reliability of the network.

Product Usage

LED status indicator

The system includes an RGB LED that shows the device’s status during use:
One single BLUE blink: when connecting to the power supply and the device is not yet included in the Z-Wave network
OFF: the relay is OFF
Solid GREEN: the relay is ON
Blink GREEN - BLUE: Learn mode for Inclusion and Exclusion
Blink GREEN - the device is indicating Overcurrent event
Blink BLUE - the device is indicating Overvoltage event

Overvoltage and Overcurrent Alarms
WiDom Smart Plug is able to detect overvoltage and overcurrent events, and show them through a blinking LED:
- Blink GREEN - Overcurrent event
- Blink BLUE - Overvoltage event
These events generate alarms that can control associated devices, by sending Basic Set Commands and open the relay in case of the overcurrent alarm.

Reset to factory default The device can be reset to the original factory settings by removing the device from the Z-Wave Network.
Inclusion Press the button 3 times
Exclusion Press the button 3 times
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 8 Lifeline
2 8 Over Current
3 8 Over Volage
4 8 On/Off Control 1 Click
5 8 On/Off Control 2 Click

Configuration Parameters

Parameter 1: Local load control

Defines which sequences of click control the local load.
Size: 1 Byte, Default Value: 3

Setting Description
1 1 click turn ON/OFF the local load
2 2 click turn ON/OFF the local load
3 1 click or 2 clicks turn ON/OFF the local load

Parameter 2: Level used to control the devices associated to group 4

Defines how to control the devices associated to 1 click event.
Size: 1 Byte, Default Value: 100

Setting Description
0 The associated devices are switched OFF
1 - 99 The associated devices (dimmer, roller shutters) are set to the indicated level
100 If the relay is ON/OFF, the associated devices are ON/OFF
255 The associated devices are switched ON

Parameter 3: Level used to control the devices associated to group 5

Defines how to control the devices associated to 2 clicks event.
Size: 1 Byte, Default Value: 100

Setting Description
0 The associated devices are switched OFF
1 - 99 The associated devices (dimmer, roller shutters) are set to the indicated level
100 If the relay is ON/OFF, the associated devices are ON/OFF
255 The associated devices are switched ON

Parameter 4: Overvoltage level

Defines the voltage level (in Volts) beyond which an overvoltage event is identified and the overvoltage timer is activated. The timer is reset when the event ceases, i.e. when the voltage returns below the overvoltage level. As soon as an overvoltage event occurs, the LED starts a BLUE blinking. If the overvoltage event ceases before the overvoltage timer expires, the blue blinking is stopped, otherwise the alarm is generated and the blinking reset is established by parameter 6.
Size: 2 Byte, Default Value: 253

Setting Description
110 - 260 Defines the overvoltage level (in Volts)

Parameter 5: Overvoltage Timer

Define the time (seconds) in which the voltage must persist above the overvoltage level so that an alarm is generated.
Size: 2 Byte, Default Value: 5

Setting Description
1 - 3600 Overvoltage time interval (in seconds) after witch an alarm is generated

Parameter 6: Overvoltage Alarm Reset

Define how to reset the overvoltage alarm and breaks off the blue blinking.
Size: 1 Byte, Default Value: 0

Setting Description
0 Manual when the relay change its state through the Push Button
1 When the overvoltage event is terminated

Parameter 7: Level used to control the devices associated to group 3

Define how to control the devices associated to the overvoltage alarm
Size: 1 Byte, Default Value: 0

Setting Description
0 The associated devices are switched OFF
1 - 99 The associated devices (dimmer, roller shutters) are set to the indicated level
255 The associated devices are switched ON

Parameter 8: Overcurrent level

Defines the current level (in Amps) beyond which an overcurrent event is identified and the overcurrent timer is activated. The timer is reset when the event ceases, i.e. when the current returns below the overcurrent level. As soon as an overcurrent event occurs, the led starts a red blinking. If the overcurrent event ceases before the overcurrent timer expires, the red blinking is stopped, otherwise the alarm is generated and the blinking reset is established by parameter 10.
Size: 1 Byte, Default Value: 12

Setting Description
1 - 12 Defines the overcurrent level (in Amps)

Parameter 9: Overcurrent Timer

Define the time (seconds) in which the current must persist above the overcurrent level so that an alarm is generated and the relay is opened.
Size: 2 Byte, Default Value: 10

Setting Description
1 - 3600 Overcurrent time interval (in seconds) after witch an alarm is generated

Parameter 10: Overcurrent Alarm Reset

Define how to reset the over-current alarm and breaks off the red blinking.
Size: 1 Byte, Default Value: 1

Setting Description
0 Manual when the relay change its state through the Push Button
1 When the over-voltage event is terminated

Parameter 11: Level used to control the devices associated to group 2

Define how to control the devices associated to the overcurrent alarm.
Size: 1 Byte, Default Value: 0

Setting Description
0 The associated devices are switched OFF
1 - 99 The associated devices (dimmer, roller shutters) are set to the indicated level
255 The associated devices are switched ON

Technical Data

Dimensions 69 x 40 x 40 mm
Weight 60.88 gr
Hardware Platform ZM5101
EAN 8059265060054
IP Class IP 20
Voltage 230 V
Load 13 A
Device Type Smart Plug
Generic Device Class Binary Switch
Specific Device Class Binary Power Switch
Firmware Version 00.02
Z-Wave Version 06.04
Z-Wave Product Id 0x0149.0x1214.0x0700
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW
EuropeSmart Plug