Pressing any sequence of click on the integrated button.
Reset to factory default | Press 6 consecutive clicks on the integrated button. |
Inclusion | Pressing any sequence of click on the integrated button. |
Exclusion | Pressing any sequence of click on the integrated button. |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 8 | Lifeline |
2 | 8 | Controls relays or dimmers |
3 | 8 | Controls relays or dimmers |
4 | 8 | Controls relays or dimmers |
Define which sequences of click control the local load. Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
0 | Local Control disabled |
1 | 1 click control the local load |
2 | 2 clicks control the local load |
3 | 1 clicks and 2 clicks control the local load |
Size: 1 Byte, Default Value: 100
Setting | Description |
---|---|
50 - 100 | 50-100% opening level (100% correspond to completely open) |
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 49 | 0-49% opening level (0 correspond to completely closed) |
Defines the actions to be carried out on the associated devices in terms of Basic Set. Size: 1 Byte, Default Value: 255
Setting | Description |
---|---|
0 | Off |
1 - 99 | Dimming purpose |
255 | ON |
Defines the actions to be carried out on the associated devices in terms of Basic Set. Size: 1 Byte, Default Value: 255
Setting | Description |
---|---|
0 | Off |
1 - 99 | Dimming purpose |
255 | ON |
Defines the actions to be carried out on the associated devices in terms of Basic Set. Size: 1 Byte, Default Value: 255
Setting | Description |
---|---|
0 | Off |
1 - 99 | Dimming purpose |
255 | ON |
Defines the actions to be carried out on the associated devices in terms of Basic Set. Size: 1 Byte, Default Value: 255
Setting | Description |
---|---|
0 | Off |
1 - 99 | Dimming purpose |
255 | ON |
Defines the actions to be carried out on the associated devices in terms of Basic Set. Size: 1 Byte, Default Value: 255
Setting | Description |
---|---|
0 | Off |
1 - 99 | Dimming purpose |
255 | ON |
Defines the actions to be carried out on the associated devices in terms of Basic Set. Size: 1 Byte, Default Value: 255
Setting | Description |
---|---|
0 | Off |
1 - 99 | Dimming purpose |
255 | ON |
Setting | Description |
---|---|
0 | Calibration to be done in automatic mode |
1 | Calibration has been done |
2 | Calibration to be done in manual mode |
Defines the level of power consumption under which the motor is considered in idle state Size: 2 Byte, Default Value: 1000
Setting | Description |
---|---|
0 - 3000 | Expressed in hundredths of Watt (ex. 3000=30 Watt) |
Defines the time after which, a power consumption lower than the PLIMIT (the power defined in parameter No. 21) is considered as reaching the limit switch Size: 1 Byte, Default Value: 30
Setting | Description |
---|---|
0 | Limit Switch ignored |
1 - 127 | Expressed in tenths of seconds |
Dimensions | 37x37x17 mm mm |
Weight | 26.6 gr |
Hardware Platform | ZM5101 |
EAN | 8059265060092 |
IP Class | IP 20 |
Voltage | 230 V |
Load | 1200 W |
Device Type | Roller Shutter |
Generic Device Class | Multilevel Switch |
Specific Device Class | Motor Control Device (C) |
Firmware Version | 01.00 |
Z-Wave Version | 06.04 |
Z-Wave Product Id | 0x0149.0x1214.0x0800 |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |