Quickstart

This is a On/Off Power Switch for XXXQFrequencyName. To run this device please insert fresh 1 * CR123 batteries. To run this device please make sure the internal battery is fully charged.

Inclusion, Exclusion and wakeup are confirmed by one second clicking the program switch inside the case.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

This sensor monitors leakage and sends an alarm when flooding or leakage is detected. The sensing device can be away up to 2 m from the main device. The unit can be mounted on every flat surface. The installation can be done with screws or double-sided tape.

The device is a battery-powered device, which is in non-operating state unless an action is detected. After a programmable sleeping time the device wakes up and sends status information. After this the unit goes back to non-operating state. The unit will sends a warning to the Z-Wave controller, when batteries need to be replaced. The units send information to a controller or any other associated Z-Wave device. The device has a tamper switch which sends an alarm to the controller when it will be opened.

Installation

  • Open the Sensor"s casing by unscrewing the battery cover.
  • Put the CR123A battery in the battery compartment according to the marking.
  • The LED will start to flash slowly, which means the sensor in not included into a Z-Wave network.
  • Bring your main controller into Inclusion mode.
  • Press the program switch inside the case for at least 1 second.
  • Refit the battery cover with the fixing screw.
  • For mounting use adhesive tape or mounting screws.

NOTE: A clean smooth surface is required to mount the Flood Sensor securely. The length of flood sensor cable is 2 meters. If the cable is too long, roll up the cable and fasten it by twist ties. The transceiver should be placed as high up as possible on the wall to improve communication and to prevent it from coming into contact with water in case of flooding.

Product Usage

  1. When water is detected, the sensor transmits radio signal to controller.
  2. In normal operation the LED in the device will not light.
  3. If the cover of the device is removed, the tamper switch will send a signal according the status, the LED will go solid. The sensor will go to wake up, when it is opened.

Reset to factory default XXXResetDescription
Inclusion

Make sure that your Z-Wave Controller is in the Inclusion-/Exclusion-Mode. Click one second on the program switch inside the device to confirm the process.

Exclusion

Make sure that your Z-Wave Controller is in the Inclusion-/Exclusion-Mode. Click one second on the program switch inside the device to confirm the process.

NIF

Click one second on the program switch inside the device or a detected action by the sensor sends a Node Information Frame.

Wakeup

Click one second on the program switch inside the device or a detected action by the sensor will wake up the device and keep it awake.

Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Flood detected

Technical Data

Dimensions 0.0420000x0.0740000x0.0260000 mm
Weight 35 gr
Hardware Platform ZM3102
Battery Type 1 * CR123
Device Type On/Off Power Switch
Generic Device Class Binary Switch
Firmware Version 0e.01
Z-Wave Version 03.53
Certification ID ZC10-14040002
Z-Wave Product Id 0109.2005.0505
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW
EuropeOn/Off Power Switch