Quickstart

This is a secure Notification Sensor for XXXQFrequencyName. To run this device please make sure the internal battery is fully charged. Put the Z-Wave Interface Controller into 'inclusion' mode, and follow its instructions to add the ZP3102 to your Z-Wave network. For a successful inclusion, it is suggested to have the sensor and your Z-Wave controller about one meter apart. Press the Program Switch of the ZP3102 (refer to the manual for the location of the program switch) ready the ZP3102 for inclusion into the Z-Wave network. If inclusion does not take place or is unsuccessful within 20 seconds, the ZP3102 will go to sleep; if this happens, simply repeat pressing the program switch to try again.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

The ZP3102 is a Z-Wave enabled motion detector and temperature sensor. The motion detector has 120 degrees of horizontal visibility and 60 degrees of vertical visibility. The temperature sensor that is built in to the ZP3102 is capable of reporting in both Celsius and Fahrenheit scales, and may be queried for the temperature and it will report it automatically when it detects changes. The sensor is battery operated and includes the ability to report the battery level and will transmit an alert signal if the battery assumes a critically low level. The ZP3102 is future-proofed by also supporting the ability to have its firmware updated over the Z-Wave network.

Reset to factory default Removing the rear cover to wake up the device. Press Program Switch 10 times within 10 seconds, ZP3102 will go back to factory default. (This is to be used only in the case of the primary controller being inoperable or otherwise unavailable.)
Inclusion Put the Z-Wave Interface Controller into 'inclusion' mode, and follow its instructions to add the ZP3102 to your Z-Wave network. For a successful inclusion, it is suggested to have the sensor and your Z-Wave controller about one meter apart. Press the Program Switch of the ZP3102 (refer to the manual for the location of the program switch) ready the ZP3102 for inclusion into the Z-Wave network. If inclusion does not take place or is unsuccessful within 20 seconds, the ZP3102 will go to sleep; if this happens, simply repeat pressing the program switch to try again.
Exclusion Put the Z-Wave Interface Controller into “exclusion” mode, and following its instruction to delete the ZP3102 to your Z-Wave network. Press the Program Switch of ZP3102 once to be excluded. The LED on the ZP3102 should start to flash.
NIF XXXNIF
Wakeup Remove the rear cover to wake up the device, or set the wake up interval time from 10 minutes to 1 week. The battery will be drained quickly if you fail to replace the cover after using that method to wake up the device.
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Z-Wave Plus Lifeline

Configuration Parameters

Parameter 1: Retriggering Time

User could set up the retriggering time from 1 ~ 255 minutes using values 0x00 to 0xFF (-128 to 127).
Size: 1 Byte, Default Value: 3

Setting Description
1 - 255 Retriggering Time

Parameter 2: Temperature Scale

User could choose the temperature reported scale by following: 0x00 - Celsius 0x01 - Fahrenheit
Size: 1 Byte, Default Value: 0

Setting Description
0 - 1 Temperature type

Parameter 3: Infrared sensor sensitivity

Infrared sensor sensitivity adjustment: 1 = most sensitive 7 = most insensitive
Size: 1 Byte, Default Value: 4

Setting Description
1 - 7 Sensitivity Adjustment

Technical Data

Dimensions 85x62x50 mm
Weight 63 gr
Hardware Platform ZM5202
EAN 0019962005305
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Z-Wave Version 6.51.02
Certification ID ZC10-14100005
Z-Wave Product Id 0x0109.0x2002.0x0205
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW
EuropeNotification Sensor