Quickstart

This is a Thermostat - HVAC for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
Inclusion/exclusion modeTo include the thermostat to your home automation gateway, press the Center (confirm) button for 10 seconds.The display will show OFF. Press Right (down) button 4 times till you see Con in the display. Now start adding device in your home automation software. Start inclusion mode by pressing Center (confirm) button for approximately 2 seconds. The inclusion/exclusion icon will appear in the display.Confirmation will show Inc/EcL in the display. If inclusion fails, Err (error) will appear.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

Heatit Z-Wave is an electronic thermostat for mounting in a standard wall box. The thermostat has a built-in Z-Wave chip that can be connected to Home Automation systems like Fibaro, Sensio, Vera, Zipato and others.The display will show the actual room temperature.By pressing the buttons, the display will show the set value.Heatit Z-Wave is equipped with a single-pole switch. The thermostat can handle loads up to 16A/3600W at 230V.If the load is greater than this, the thermostat needs to be connected to a contactor. It can be used with two external temperature sensors.Functions: Room sensor Floor sensor Temperature limiter Power regulator Z-Wave chip 500 series Week program/setback temperature via gateway Setback mode 7-segment white LCD-screen Can be used in connection with different NTC-sensors Lock mode/child lock Backlight Calibration 8 scenariosCONNECTION CLAMPSUse 1,5 mm or 2,5 mm cables according to power need.TECHNICAL DATARated voltage: 230 V 50/60 HzMax. load: 3600WMax. current: 16APower consumption: 1,5WProtection class: IP21Min/Max installation temp: -20C to 40CMin/Max operating temp: 5C to 40CTemperature intervals: Floor sensor 5C to 40CRoom sensor 5C to 40CHysteresis: 0,5CSensor values: 0C 29,1 kOhm10C 18,6 kOhm15C 15,1 kOhm20C 12,2 kOhm25C 10,0 kOhmBreaker: Single-pole

Reset to factory default Factory reset - RES:By pressing buttons Left and Center(up and confirm) for 20 seconds, the thermostat will perform a complete factory reset.NB! Please use this procedure only when the primary controller is missing or otherwise inoperable.
Inclusion Inclusion/exclusion modeTo include the thermostat to your home automation gateway, press the Center (confirm) button for 10 seconds.The display will show OFF. Press Right (down) button 4 times till you see Con in the display. Now start adding device in your home automation software. Start inclusion mode by pressing Center (confirm) button for approximately 2 seconds. The inclusion/exclusion icon will appear in the display.Confirmation will show Inc/EcL in the display. If inclusion fails, Err (error) will appear.
Exclusion Inclusion/exclusion modeTo include the thermostat to your home automation gateway, press the Center (confirm) button for 10 seconds.The display will show OFF. Press Right (down) button 4 times till you see Con in the display. Now start adding device in your home automation software. Start inclusion mode by pressing Center (confirm) button for approximately 2 seconds. The inclusion/exclusion icon will appear in the display.Confirmation will show Inc/EcL in the display. If inclusion fails, Err (error) will appear.
NIF XXXNIF
Wakeup If Er2 appears in the display, touch any button to restart the display.
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 8 Z-Wave Plus Lifeline

Technical Data

Hardware Platform ZM5202
Device Type Thermostat - HVAC
Network Operation Always On Slave
Firmware Version 01
Z-Wave Version 6.51.00
Certification ID ZC10-15010002
Z-Wave Product Id 0x019B.0x0001.0x0001
Frequency XXfrequency
Maximum transmission power XXantenna
CEPT (Europe)Thermostat - HVAC