Quickstart

This is a Notification Sensor for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufactures and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.-Insert the 3 AA batteries into the battery compartment connecting the correct polarity as shown on the battery compartment lid. The Smoke Detector will emit a 2-tone beep.-The LED will start flashing and begin a 6-minute warming period.-Put the Z-wave gateway or control panel into Inclusion or Learning mode (please refer to the Z-wave gateway or control panel manual).-Within 1.5 seconds, press the Test Button 3 times. The Smoke Detector will emit a 2-tone beep and the LED will turn on for ~2 seconds.-Refer to the operation manual of the Z-wave gateway or control panel to complete the learn-in process.-If the sensor has already been included (learnt) into another Z-wave Gateway/Control Panel, or if the sensor is unable to be learnt into the current Z-wave Gateway/Control Panel, please exclude it first (see Exclusion) before attempting to include it into the current Z-wave Gateway/Control Panel.-When the 6-minute warming period is over, the Smoke Detector will emit one short beep to indicate that the Smoke Detector is starting calibration process. The process will be repeated every 100 seconds and notified by a short beep respectively. The Smoke Detector will emit a 2-tone beep and the LED will turn off to indicate calibration is completed.-Normal calibration process lasts 2 - 16 minutes.-If the Smoke Detector emits continuous beeps after 16 minutes, the calibration has failed. Remove the batteries to silence the continuous beeps.-Restart the calibration process by re-inserting the batteries.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

The SD-8ZW is a Z-Wave smoke detector with a built-in siren to sound audible alerts when alarms occur. The SD-8ZW triggers alarms by using latest optical chamber technology to detect harmful smoke particles enter its detection chamber.

Reset to factory default (Only use factory reset when network Control Panel/Gateway is missing or inoperable).-Press and hold the Test Button of the Smoke Detector for 8 seconds to factory reset.
Inclusion This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufactures and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.-Insert the 3 AA batteries into the battery compartment connecting the correct polarity as shown on the battery compartment lid. The Smoke Detector will emit a 2-tone beep.-The LED will start flashing and begin a 6-minute warming period.-Put the Z-wave gateway or control panel into Inclusion or Learning mode (please refer to the Z-wave gateway or control panel manual).-Within 1.5 seconds, press the Test Button 3 times. The Smoke Detector will emit a 2-tone beep and the LED will turn on for ~2 seconds.-Refer to the operation manual of the Z-wave gateway or control panel to complete the learn-in process.-If the sensor has already been included (learnt) into another Z-wave Gateway/Control Panel, or if the sensor is unable to be learnt into the current Z-wave Gateway/Control Panel, please exclude it first (see Exclusion) before attempting to include it into the current Z-wave Gateway/Control Panel.-When the 6-minute warming period is over, the Smoke Detector will emit one short beep to indicate that the Smoke Detector is starting calibration process. The process will be repeated every 100 seconds and notified by a short beep respectively. The Smoke Detector will emit a 2-tone beep and the LED will turn off to indicate calibration is completed.-Normal calibration process lasts 2 - 16 minutes.-If the Smoke Detector emits continuous beeps after 16 minutes, the calibration has failed. Remove the batteries to silence the continuous beeps.-Restart the calibration process by re-inserting the batteries.
Exclusion The Smoke Detector must be removed from existing Z-wave network before being included into another. There are two methods available to exclude a device.Exclusion Mode-Put the Z-wave gateway or control panel into Exclusion mode (please refer to the Z-wave gateway or control panel manual).-Within 1.5 seconds, press the Test Button 3 times and the Smoke Detector will be removed from the Z-wave network.
NIF XXXNIF
Wakeup This function uses the Z-Wave Wake Up Command Class. The Wake Up Command Class allows the battery-powered Heat Detector to notify the Control Panel/Gateway that it is awake and ready to receive any queued commands. The wake up interval time period is programmed automatically according to Control Panels setting when The Heat Detector is included. The recommended setting of the interval time is between 30 to 60 minutes.
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
3 5 Group 1 for LifeLine:Notification CC,V4 (COMMAND_CLASS_NOTIFICATION)Battery CC (COMMAND_CLASS_BASIC)Device Reset Locally CCGroup 2 for Basic Set:Basic CC, v2 (COMMAND_CLASS_BASIC)Group 3 for Notification Report:Notification CC,V4 (COMMAND_CLASS_NOTIFICATION)

Technical Data

Hardware Platform ZM5202
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Firmware Version 01
Z-Wave Version 6.51.06
Certification ID ZC10-15080007
Z-Wave Product Id 0x018E.0x0003.0x0001
Frequency XXfrequency
Maximum transmission power XXantenna
CEPT (Europe)Notification Sensor