Quickstart

This is a Routing Multilevel Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply.

 Inclusion and Exclusion are confirmed by a tripple click of the button.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

This is a wall plug dimmer that can be placed between a type F wall outlet and electric devices, plugged in by cord. It can dim all incandescent lights, high voltage halogen lamps and transformers operated low voltage lamps without any restriction. Special optimization functions support the dimming of the majority of dimmable LED lights and Compact Fluorescent Lights (CFLs). The device is IP20 rated and can therefore only be used in dry environments. The device offers a Baby-Dim Function which dims down a lamp from a defined level into another defined level in a longer but also definable period (e.g. 20 minutes). An automatic Light-Off function and programmable dimming and switching behavior makes the device a very flexible tool for inhouse lighting.

Installation

The plug can be plugged into every wall outlet for Plug-Type  F. It is IP20 rated and can therefore only be used in dry environments. Do not locate the device facing direct sunlight, humid or dusty place. The suitable ambient temperature for the device is 0°C ~ 40°C. Plugs must not be stacked and operated.

Product Usage

The device is able to dim electric loads up to 300 W. The device can be dimmed wirelessly or using the local button.

Local Operation
The local button has the following functions:

  • If light is off a short press on the button will turn it either on 100 % or to the last dimming level before turning off
  • If light is on - regardless of dimming level - a short press on the button will turn the light off
  • Keep the button pressed starts to change dimming level slowly. The direction of dimming (up or down) depends on the direction of the last slow dimming.

The behavior of the button can be configured.

LED Usage
The device has one blue LED used to indicate status information. The behavior of the blue LED can be configured:

  • It may show the dimming state. This is the default option.
  • It may serve as night light. So it"s on when the light is off.
  • It"s deactivated.
  • It can be controlled wirelesly and used as an indicator for other advanced functions.

Automated Dimming Function
If activated the dimmer will turn off automatically after a defined time. This function is particularly useful if the dimmer is turned on using a motion detector of any other type of sensor. In this case it"s possible to further define the reaction of the dimmer on certain signals sent from a sensor. This allowes a very flexible application of the dimmer in the house.

Baby Sleeping Function
The device can be used to help babies and little children to find sleep. (It"s save to use the device in childrens rooms or closed to their beds due to the special shutter function that shield the high voltage from touching). When enabled a double click of the button will turn the light into a definable level and then it will gradually dim down over time. The time of dimming and the target dimming state - e.g. off - can be configured as well.

Dimming LEDs and CFLs
LEDs and Compact Flouroscent lights are complicated to dim for two reasons:

  • There are a so-called reactive load. At the moment of switching on they have virtually not resistance causing a very high inrush current that may destroy the dimmer device.
  • The light emission is based on an electronics that may not crease light according to the input power the dimmer is able to regulate.

There are special LEDs or CFLs that claim to be dimable however almost none of them can be dimmed in the full range of 0% to 100%. Some will flicker at very low dimming level or sometimes on 100% dimming. This flickering is not only annoying but also destroys the lighting device. This dimmer allows to set a lower (configuration parameter 17) and a higher (configuration parameter 18) border for dimming and surpress the dimming levels that are not supported by the device. On default the dimmer will dim between 0% and 100%. If you see problems at certain dimming levels, detect the dimming level at your controlling gateway (reading the dimming value) and change the configuration so that this dimming level will not reached anymore. The extreme case would be to only support 0% (off) and full diming level (on). This function is supported by all lights regardless of the technology. In this mode it is recommended to set the fast dimming speed to 0 (Instantly) using configuration parameter no. 5.

Advanced Options for LED and CFL tweakings
The configuration parameters No 51 - 54 allow to configure the dimming behavior on a very technical level. Do not touch these values unless you know what you do! A dimmer is controlled by the Zero Crossing signal and the TRIAC Fire pulse. The TRIAC fires every half sine wave max one time. A fire cycles starts with the Zero Crosssing and then lasts 156 pulse length increments. The value #51 defines the minimum time after zero crossing because the Triac can fire regardless of the dimming level. Parameter #54 defines whether the fire pulse has defines length (short) or is extended as long as allowed by the minimum start value in parameter #54 and the minimum trailing value defines by #53. This value defines the minimum time the pulse will not be active because of the next zero crossing signal.

Reset to factory default XXXResetDescription
Inclusion

Inclusion and Exclusion are confirmed by a tripple click of the button.

Exclusion

Inclusion and Exclusion are confirmed by a tripple click of the button.

NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Send Reports on blind state change

Configuration Parameters

Parameter 1: LED mode

Set LED indication mode
Size: 1 Byte, Default Value: 03

Setting Description
00 Disabled
01 Show switch state
02 Night mode (inverted switch state)
03 Operated by Indicator Command Class

Parameter 2: Automatically switch off after

If not zero, automatically switch off after a user defined time
Size: 2 Byte, Default Value: 0000

Setting Description
0000 Disabled
0001 - ffff sec

Parameter 3: What to do on RF off command

Defines how to interpret RF Off command. Can be used in conjunction with Auto Off function: Ignore - to switch on the light by motion detectors and switch it off after some amount of time: in case of multiple motion detectors each would try to switch the light off that would break logics; Switch on - to switch on the light on both On and Off paddle press on the remote and switch it off after some amount of time. Button off click will still work (if button operations are not disabled).
Size: 1 Byte, Default Value: 00

Setting Description
00 Switch off
01 Ignore
02 Switch on
03 Switch on if load is off else switch off

Parameter 4: Ignore start level

Defines if the dimmer shall ignore start level in StartLevelChange command despite it is specified or not
Size: 1 Byte, Default Value: 01

Setting Description
00 No
01 Yes

Parameter 5: Speed for fast dimming

Time to dim on button presses and Set command (if it has no duration specified). If not 0, dimming will be done smoothly to preserv bulb life.
Size: 1 Byte, Default Value: 1e

Setting Description
00 Instantly
01 - ff in 10ms units

Parameter 6: Speed for slow dimming

Time to dim on button holds and StartLevelChange command (if it has no duration specified).
Size: 1 Byte, Default Value: 03

Setting Description

Parameter 7: Behavior on Switch On

Defines the dim level on command ON. On default he dimmer restores last dim level. This parameter allows to configure to set maximum level on second On command (if already On) or to always switch on to maximum level
Size: 1 Byte, Default Value: 00

Setting Description
00 last dim level
01 maximum dim level when already turned on
02 Always maximum dim level

Parameter 8: Baby Dimming time

Time to dim on double click Off button for Baby-Dim function. This function works only if the load is operated by single press and hold button action. If enabled, the device will wait for a click timeout to see if the second click would be pressed. This will introduce a small delay for single click commands
Size: 1 Byte, Default Value: 00

Setting Description
00 Disabled
01 - 63 in minutes

Parameter 9: Target dimming level for Baby Dimming

Target level on which to stop while executing Baby Dimming. Can be 0 to completely switch off the light.
Size: 1 Byte, Default Value: 00

Setting Description

Parameter 10: Typical click timeout

Typical time used to differenciate click, hold, double and triple clicks
Size: 1 Byte, Default Value: 32

Setting Description

Parameter 17: Limit minimal light level

Minimal level should be greater than maximal
Size: 1 Byte, Default Value: 01

Setting Description

Parameter 18: Limit maximal light level

Maximal level should be greater than minimal
Size: 1 Byte, Default Value: 63

Setting Description
00 Work as switch: use off and maximal level
0a - 63 Level limit

Parameter 19: Dim Level on Switch On

defines how the dimmer hall react on a simple ON Command.
Size: 1 Byte, Default Value: 00

Setting Description
00 Use previous light level
01 - 63 Define light level in %

Parameter 51: Pause before pulse

NB: Do not touch these settings if you are not sure what they mean! For dimmable LEDs and CFL with bypass use value 10. For other bulbs use default value.
Size: 1 Byte, Default Value: 1c

Setting Description

Parameter 52: Pause after pulse

NB: Do not touch these settings if you are not sure what they mean! For dimmable LEDs and CFL with bypass use value 40. For other bulbs use default value.
Size: 1 Byte, Default Value: 1c

Setting Description

Parameter 53: Pulse width

NB: Do not touch these settings if you are not sure what they mean! For dimmable LEDs and CFL with bypass use value 20. For other bulbs use default value.
Size: 1 Byte, Default Value: 0a

Setting Description

Parameter 54: Pulse type

NB: Do not touch these settings if you are not sure what they mean!
Size: 1 Byte, Default Value: 00

Setting Description
00 Long pulse
01 Short pulse

Technical Data

Dimensions 0.0590000x0.1020000x0.0760000 mm
Weight 130 gr
EAN 696859123580
Device Type Light Dimmer Switch
Generic Device Class Multilevel Switch
Specific Device Class Routing Multilevel Switch
Firmware Version 01.00
Z-Wave Version 03.2a
Certification ID ZC08-13070024
Z-Wave Product Id 0x0154.0x0202.0x0611
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW
EuropeLight Dimmer Switch