This is a
This device measures the three air quality parameters temperature, humidity and dew point an reports them to a central controller. Beside this the device can directly control groups of other Z-Wave devices on over- and undershooting a set temperature and/or humidity parameter. This can be used to establish control loops for temperature and humidity. The device wakes up every 15 minutes to measure the values and it will send unsolicited reports when values change. Additionally the device will report all values on request.
The mold detector is actively monitoring the danger of mold in a room based on the temperature and humidity and will issue alarm warnings when criticical air conditions met. Wireless Alarm and red and a green blinking LED will indicate a mold condition. This local LED warning function is also available when the device is not included in any Z-Wave network and works stand alone.
As first step you need to power the device by insertng the batteries. To access the battery compartment you need ot open the enclosure. this possible with any shap tool such as screwdriver using as leverage on one or more of the opening gaps (see image). It is also possible ot use a tool and open the device on the inlet coevrs (see image) but here you need to take care not to damage the device surface. The device can be placed on every flat surface or flat wall. Please note that air need to flow into the perforated part of the cover to reah the teperature and humidity sensor.
Once the device is powered up it will start monitoring the air parameters and warn of mold using the local red and green LED. All air parameters are measured every 15 minutes. Pushing the button will force an immediate measurement and the LEDs will indicate the danger of mold
Reset to factory default | Once Cover is removed and tamper switch is tripped, push the tamper for 5 seconds until red LED blinks. Then release tamper and push it again for 5 seconds until LED blinks. |
Inclusion | Tripple clicking the tamper button includes (adds) the device. |
Exclusion | Tripple clicking the tamper button excludes (removes) the device. |
NIF | Tripple Click the tamper button |
Wakeup | A single click on the tamper button will wakeup the device. |
Protection | XXXProtection |
FirmwareUpdate | No special action needed. |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Lifeline |
2 | 5 | Temperature High Trigger |
3 | 5 | Temperature Low Trigger |
4 | 5 | Humidity High Trigger |
5 | 5 | Humidity Low Trigger |
This value defines the minimum change of temperature to cause an unsolicited report of humidity to the central controller using Lifeline.
If the value is set to 0, there will be no reports sent to the controller, when the temperature changes. However, periodic reports, managed by configuration parameter 4, may still be active.
Size: 1 Byte, Default Value: 20
Setting | Description |
---|---|
1 - 100 | 1/10 degree |
0 | disabled |
This value defines the minimum change of humidity to cause an unsolicited report of humidity to the central controller using Lifeline.
If the value is set to 0, there will be no reports sent to the controller, when the humidity changes. However, periodic reports, managed by configuration parameter 4, may still be active.
Size: 1 Byte, Default Value: 7
Setting | Description |
---|---|
1 - 20 | % |
0 | disabled |
This parameter defines the time interval to send an unsolicited report.
If the value is set to 0, there will be no periodic reports sent to the controller. However, reports on temperature/humidity changes, managed by configuration parameters 1 and 2, may still be active.
Size: 2 Byte, Default Value: 43200
Setting | Description |
---|---|
900 - 65535 | Seconds |
0 | disabled |
This parameter defines a temperature. If the measured temperature surpasses this watermark a BASIC command is sent into Association Group 2 Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
1 - 1000 | 1/10 degree |
0 | disabled |
This parameter defines a temperature. If the measured temperature dropps below this watermark a BASIC command is sent into Association Group 3 Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
-200 - 1000 | 1/10 degree |
0 | disabled |
This parameter defines a relative humidity. If the measured relative humidity surpasses this watermark a BASIC command is sent into Association Group 4 Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
10 - 100 | % |
0 | disabled |
This parameter defines a relative humidity. If the measured temperature dropps below this relative humidity a BASIC command is sent into Association Group 5 Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
1 - 90 | % |
0 | disabled |
This defines what BASIC command shall be sent out into association group 3 Size: 1 Byte, Default Value: 255
Setting | Description |
---|---|
0 - 255 | Value |
This defines what BASIC command shall be sent out into association group 2 Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 255 | Value |
This defines what BASIC command shall be sent out into association group 5 Size: 1 Byte, Default Value: 255
Setting | Description |
---|---|
0 - 255 | Value |
This defines what BASIC command shall be sent out into association group 4 Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 255 | Value |
Dimensions | 25x25x10 mm |
Hardware Platform | ZM5101 |
EAN | 4251295700878 |
IP Class | IP 20 |
Battery Type | 1 * 1/2 AA |
Device Type | Notification Sensor |
Generic Device Class | Notification Sensor |
Specific Device Class | Routing Notification Sensor |
Firmware Version | 1.0 |
Z-Wave Version | 6.02 |
Z-Wave Product Id | 0154.0014.0004 |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |