Quickstart

This is a secure Notification Sensor for XXXQFrequencyName. To run this device please insert fresh 1 * LS14250 batteries. To run this device please make sure the internal battery is fully charged. Please insert the Z-Wave module including the battery into the smoke detector head first. Pressing the "Z-Wave button" includes and excludes the device.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

The Popp 10-Year Smoke Sensor consists of two parts: (1) a stand-alone smoke detector head that does not only fully comply to the European regulation EN15406 but to the much more advanced guideline vfdb 14-01. This means that the device ? among others ? ensures a 10 year battery life of the internal battery, is more resistive against mechanical stress and extreme temperature changes, and it is manufactured according to the advanced manufacturing standard UPC-2. (2) a wireless communication module, that has its own separate and replaceable battery. This module fits into the module bay of the smoke detector head and establishes a communication link to a central Z-Wave gateway reporting its battery status and of course any alarm condition. The module is certified according to the Z-Wave Plus guidelines. Additional functionality of this high end smoke detector includes periodic automated self test, dust compensation and special functions for sleeping rooms (no blinking) and easiness of use (large button for testing to be operated by a simple broom stick). Furthermore the device can be used also as an independent indoor siren within the Z-Wave network. Connected to different sensors via control center it will alarm in case of detected flood or burglary additionally to smoke or fire alarm. Yon don?t need to install another stand-alone siren.

Installation

Please refer to the installation guide of the smoke sensor for information about how and where the smoke sensor should be installed. The installation guide complies with the norm DIN EN 14676.

  • The first step is to mount the mounting base on the desired place in the home using screws.
  • Remove the battery isolation strip from the wireless module. The red LED will start blinking.
  • Include the Smoke Sensor into your existing Z-Wave based Smart Home Network using the Z-Wave button.
  • Place the Smoke Detector on the mounting base and turn clockwise. Now the Smoke Detector is armed.
  • Battery Change: The battery of the wireless module will be empty much earlier than the 10 years soldered in battery of the smoke sensor. To replace the battery, remove the Smoke Detector, pull off the wireless module from the smoke sensor. Then you can replace the 1/2 AA battery and replug the wireless module.

Product Usage

In case smoke is detected by the smoke detector the device will sound and the wireless module will issue a Z-Wave alarm command to the main controller and other associated devices. A low battery of the wireless module will be reported by the wireless module. Please note that the battery level of the main detector is not reported since this battery can?t be replaced anyway. The end-of-life indicator serves the same purpose. Outside Inside 3 Note: All communication of the wireless module is performed with application level security if the device was included securely and all communication partners support secure communication as well. In case a non-secure device is associated for switching on smoke alarm, the smoke detector will detect this and change its communication style with this very device to non-secure. This process happens one time and will take about 20 seconds. This delay will happen on first communication only.

Alarm Messages The device will issue the following (unsolicited) alarm messages:

  • Smoke Detected (this message will also be issued when the test button is pressed)
  • Low Battery Alarm (when the battery of the wireless modules goes low), indicated by yellow LED
  • Tamper Detected (ON, when the smoke detector head is removed from the base; OFF, when the detector head is mounted to the base)
  • End of Life (issued, when the Detector Main Head has reached its end of life after 10+ years.)

Reset to factory default To reset the device keep the button pushed for 10 seconds. After 5 seconds the led starts flashing and after another 5 seconds there is a short beep signaling the successful reset back to factory defaults. Use this procedure only when the network primary controller is missing or otherwise inoperable.
Inclusion
1. Remove the ceiling bracket.
2. Remove the Z-Wave board. 
3. Insert the battery.
4. Re-insert the Z-Wave module.
5. Press the button for 3 seconds.
Exclusion
1. Remove the ceiling bracket.
2. Press the button once.
NIF A single click on the button will send out a NIF.
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate Once the firmware update process has started double click the Z-Wave button to confirm firmware update process.
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 10 Z-Wave Plus Lifeline
2 10 Alarm Reports. All devices in this group will receive Alarm notifications (Smoke , Battery Low, Tamper)
3 10 Switching Command. All devices in this group will receive a BASIC SET command on Smoke Alarms. Configuration parameter 3 and 4 will define the command value sent on alarm and alarm clearance.

Configuration Parameters

Parameter 3: Value of ON-Command

This value is sent as BASIC Set to Association Group 3 when an Smoke Alarm occurs.
Size: 1 Byte, Default Value: 99

Setting Description
0 - 99 BASIC Set Command
255 BASIC Set Command

Parameter 4: Value of Off-Command

This value is sent as BASIC Set to Association Group 3 when an Smoke Alarm is cleared.
Size: 1 Byte, Default Value: 99

Setting Description
0 - 99 Basic Set Command
255 Basic Set Command

Technical Data

Dimensions 115x115x47 mm
Weight 202 gr
Hardware Platform ZM5202
EAN 0019962009402
IP Class IP 20
Battery Type 1 * LS14250
Device Type Notification Sensor
Network Operation Listening Sleeping Slave
Firmware Version 1.14
Z-Wave Version 6.51.06
Certification ID ZC10-16015002
Z-Wave Product Id 0x0154.0x0004.0x0004
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW
EuropeNotification Sensor