Quickstart

This is a secure On/Off Power Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply. 1. Put your Z-Wave controller into inclusion mode by following the instructions provided by the controller manufacturer. 2. Pressing On/Off button three times within 2 seconds will enter inclusion mode.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

This plug-in ON/OFF switch PAN16 is a security enabled Z-Wave Plus product, based on Z-Wave Plus technology. The device will enable security mode automatically if the controller supports security mode, too. Z-Wave PlusTM enabled devices displaying the Z-Wave PlusTM logo can also be used with it regardless of the manufacturer, and can also be used in other manufacturer’s Z-WaveTM enabled networks. Remote On/Off control of the connected load is possible with other manufacturer’s wireless Controller. Each switch is designed to act as a repeater. Repeaters will re-transmit the RF signal to ensure that the signal is received by its intended destination by routing the signal around obstacles and radio dead spots. Because PAN16 supports Security Command Class, it can learn with a Secured enabled Z-Wave controller to fully utilize the device. Its functionality and supported command classes is identical when included as a secure and non-secure device.
This plug-in ON/OFF switch is able to detect instance wattage (3000W/230VAC) (13Ampere) and overload current (14.5A with resistive load) of connected lights or appliances. When detecting overload state, the Switch will be disabled and its On/Off button will be lockout of which LED will flash quickly. However, unplug and re-connect the switch will reset its overload condition to normal status.
Adding to Z-WaveTM Network
In the front casing, there is an On/Off button with LED indicator which is used to toggle switch on and off or carry out inclusion, exclusion, reset or association. When first power is applied, its LED flashes on and off alternately and repeatedly at 0.5 second intervals. It implies that it has not been assigned a node ID and start auto inclusion.
Auto Inclusion
The function of auto inclusion will be executed as long as the switch does not have Node ID and just plug the switch into a wall outlet.
Note: Auto inclusion timeout is 2 minute during which the node information of explorer frame will be emitted once several seconds. Unlike “inclusion” function as shown in the table below, the execution of auto inclusion is free from pressing the On/Off button on the Switch.

Installation

1. Plug this On/Off Switch into a wall outlet near the load to be controlled.
2. Plug the load into the Switch. Make sure the load to be controlled cannot exceed 13A.
3. Press the button or switch on the load to the ON position.
4. To manually turn ON the Switch, press and release the On/Off button. The LED will turn ON, and the load plugged into the Switch will also turn ON.
5. To manually turn OFF the Switch, simply press and release the On/Off button. The LED will turn OFF and the load plugged into the Switch will also turn OFF.

Product Usage

1. Do not locate the Switch facing direct sunlight, humid or dusty place.
2. The suitable ambient temperature for the Switch is 0°C~40°C.
3. Do not locate the Switch where exists combustible substances or any source of heat, e.g. fires, radiators, boiler etc.
4. After putting it into use, the body of Switch will become a little bit hot of which phenomenon is normal.




Reset to factory default 1. Pressing On/Off button three times within 2 seconds will enter inclusion mode.
2. Within 1 second, press On/Off button again for 5 seconds.
3. IDs are excluded.
Inclusion Pressing On/Off button three times within 2 seconds will enter inclusion mode.
Exclusion Pressing On/Off button three times within 2 seconds will enter exclusion mode.
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 1 Z-Wave Plus Lifeline

Configuration Parameters

Parameter 1: Watt Meter Report Period

If the setting is configured for 1hour (set value =720), the PAN16 will report its instant power consumption every 1 hour to Group1 node. The maximum interval to report its instant power consumption is 45 hours (5s*32767/3600=45hr).
Size: 2 Byte, Default Value: 720

Setting Description
1 - 32767 720*5s=3600s=1 hour

Parameter 2: KWH Meter Report Period

If the setting is configured for 1hour (set value =6), the PAN16 will report its Accumulated Power Consumption (KW/h) every 1 hour to Group1 node. The maximum interval to report its Accumulated Power Consumption (KW/h) is 227.55 days (10min*32767/1440=227.55 days).
Size: 2 Byte, Default Value: 6

Setting Description
1 - 32767 6*10min=1 hour

Parameter 3: Threshold of current for Load Caution

This is a warning when the current of load over the preset threshold value, if the setting value is 1300, when the load current of Relay1 over this value, PAN16 will send current meter report to warn the Group1 node, the Range of the setting value is from 10 to 1300,and the default value is 1300.
Size: 2 Byte, Default Value: 1300

Setting Description
10 - 1300 1300*0.01A = 13A

Parameter 4: Threshold of KWh for Load Caution

This is a warning when the KWh of load over the preset threshold value, If the setting value is 10000, when the Accumulated Power Consumption of Relay1 over this value, PAN16 will send KWH meter report to warn the Group1 node, minimum value is 1KWh and default value is 10000 kWh.
Size: 2 Byte, Default Value: 10000

Setting Description
1 - 10000 10000*1KWH=10000KWH

Parameter 5: Restore switch state mode

Whenever the AC power return from lost, PAN16 will restore the switch state which could be SWITCH OFF (LAST SWITCH STATE) SWITCH ON. The default setting is LAST SWITCH STATE.
Size: 1 Byte, Default Value: 1

Setting Description
0 Switch off
1 Last switch state
2 Switch on

Parameter 6: Mode of switch off function

When the mode of switch On/Off is set to 0, any command of switch off will be disabled and the On/Off function of include button will be disabled. The default setting is enable mode. When manual On/Off function is disabled, the RF command can only switch On but not Off. This is useful function for keeping the device in switch on state.
Size: 1 Byte, Default Value: 1

Setting Description
0 0 : Disable
1 1 : Enable

Parameter 7: LED indication mode

1. Show Switch Stateuff1aWhen switch is on, LED is on. When switch is off, LED is off. The default setting is Show Switch State. 2. Show Night mode - When switch is on, LED is off. When switch is off, LED is on. 3. One Flash modeuff1aWhen the state of switch changes, LED will be on only one second, then LED keeps off.
Size: 1 Byte, Default Value: 1

Setting Description
1 Show switch state
2 Show night mode
3 One flash mode

Parameter 8: Auto off timer

Whenever PAN16 switches to on, the auto off timer begin to count down. After the timer decrease to zero, it will switch to off automatically. However if Auto off timer is set as 0, the auto off function will be disabled. The default setting is 0.
Size: 2 Byte, Default Value: 0

Setting Description
0 Disable auto off function
1 - 32767 1s ~ 32767s

Parameter 9: RF off command mode

Whenever a switch off command, BASIC_SET, BINARY_SWITCH_SET, SWITCH_ALL_OFF, is received, it could be interpreted as 4 variety of commands. 1. Switch Offuff1aIt switches to OFF state. The default setting is Switch Off. 2. Ignoreuff1aThe switch off command will be ignored. 3. Switch Toggleuff1aIt switches to the inverse of current state. 4. Switch Onuff1aIt switches to ON state.
Size: 1 Byte, Default Value: 0

Setting Description
0 Switch off
1 Ignore
2 Switch toggle
3 Switch on

Parameter 11: Manual Switch Report mode

Whenever PAN16 manually switch on or off, it will send BINARY_SWITCH_REPORT to the node of group1. The default setting is Enable the function.
Size: 1 Byte, Default Value: 1

Setting Description
0 Disable
1 Enable

Parameter 12: Auto Report after Reset


Size: 1 Byte, Default Value: 1

Setting Description
0 Disable
1 Enable

Parameter 13: Adjustable Overload

1450 * 0,01A =14,5A
Size: 2 Byte, Default Value: 1450

Setting Description
450 - 1450 steps 0,01A

Technical Data

Dimensions 0.0510000x0.0750000x0.0790000 mm
Weight 105 gr
Hardware Platform ZM5202
EAN 4713698572471
IP Class IP 20
Voltage 230
Load 3000 W
Device Type On/Off Power Switch
Network Operation Always On Slave
Z-Wave Version 6.51.09
Certification ID ZC10-16105251
Z-Wave Product Id 0x013C.0x0001.0x0029
Color White
Electric Load Type Electronic with/without DimmingIncandescentFluorescent (Non-Dimming)LED
Supported Meter Type Electric Energy
Switch Type Push Button
Firmware Updatable Updatable by Consumer by RF
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW
EuropeOn/Off Power Switch