Quickstart

This is a secure Light Dimmer for U.S. / Canada / Mexico. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
Place your Z-Wave controller in "Inclusion" mode. Then tap the button once to initiation Inclusion.

Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.


Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

What is Z-Wave?

Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.

Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.

This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.

If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.

For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.

Product Description

ZLINK PD-100 is a Z-Wave Plus certified device with S2 security and SmartStart features. You can now add this device securely and with ease using QR code on the product with compatible gateways supporting S2 and Smart Start. PD-100 communicates with other Z-Wave certified devices and updates your home into a smart home. PD-100 can be used to turn any plug in lamps into a smart lamp with dimmable light bulbs, turning it On, Off, or control dimming wirelessly. Each Z-Wave device also serves as a node to repeat the signal in the network, thus, extending the overall Z-Wave mesh wireless network range.Additional Features: Power 120 VAC, 60Hz, up to 300 watts Region US: 908.4, 916 MHz Works w/ most incandescent, dimmable CFL & LED lights Plugs into Standard AC outlet Remotely controls On, Off, or Dim levels Control lights via schedule LED backlit manual On/Off button Second wall AC outlet remains free Works with any certified gateway supporting Z-Wave

Prepare for Installation / Reset

Please read the user manual before installing the product.

In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.

Reset to factory default

This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.

1. Unplug the PD-100 from the AC outlet and also unplug the power plugs of the lighting from the module (if plugged in)2. Press and hold the button on the PD-1003. Plug the PD-100 back into the AC outlet with the button pressedAfter 3 seconds, release the button. If you see the button blink, that means that PD-100 has been reset successfully.Please use this procedure only when the network primary controller is missing or otherwise inoperable.

Safety Warning for Mains Powered Devices

ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.

Inclusion/Exclusion

On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.

Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.

Inclusion

Place your Z-Wave controller in "Inclusion" mode. Then tap the button once to initiation Inclusion.

Exclusion

Place your Z-Wave controller in "Exclusion" mode. Then tap the button to initiation Exclusion.

Quick trouble shooting

Here are a few hints for network installation if things dont work as expected.

  1. Make sure a device is in factory reset state before including. In doubt exclude before include.
  2. If inclusion still fails, check if both devices use the same frequency.
  3. Remove all dead devices from associations. Otherwise you will see severe delays.
  4. Never use sleeping battery devices without a central controller.
  5. Dont poll FLIRS devices.
  6. Make sure to have enough mains powered device to benefit from the meshing

Association - one device controls an other device

Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.

Association Groups:

Group Number Maximum Nodes Description
1 1 1. Z-Wave Plus Lifeline2. Device Reset Locally Notification

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.

IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.

Parameter 10: Timer

Parameter 10 indicates the time duration of each level. The resolution is 10 milliseconds. For example a default value of 3 means the timer runs out every 30 milliseconds.
Size: 1 Byte, Default Value: 3

Setting Description
1 - 255 Parameter 10 indicates the time duration of each level. The resolution is 10 milliseconds. For example a default value of 3 means the timer runs out every 30 milliseconds.

Parameter 3: Night Light

The LED indicator will be OFF when the connected light is ON and vice versa.When value =0 the LED indicator will be OFF when the the connected light is ON, and the LED will be ON when the connected light is OFF. If value =1 the LED indicator will be ON when the connected light is ON, and the LED indicator will be OFF when the connected light is OFF. If value =2 the LED indicator will always be OFF regardless of the load status
Size: 1 Byte, Default Value: 0

Setting Description
0 - 2 When value =0 the LED indicator will be OFF when the the connected light is ON, and the LED will be ON when the connected light is OFF. If value =1 the LED indicator will be ON when the connected light is ON, and the LED indicator will be OFF when the connected light is OFF. If value =2 the LED indicator will always be OFF regardless of the load status

Parameter 9: Level

Parameter 9 indicates the number of levels when the lighting when the timer runs out.
Size: 1 Byte, Default Value: 1

Setting Description
1 - 99 Parameter 9 indicates the number of levels when the lighting when the timer runs out.

Technical Data

Hardware Platform ZM5202
Device Type Light Dimmer Switch
Network Operation Always On Slave
Firmware Version HW: 255 FW: 50.03
Z-Wave Version 6.81.00
Certification ID ZC10-18025997
Z-Wave Product Id 0x0315.0x4744.0x3032
Outdoor Use ok
Firmware Updatable Updatable by Consumer by RF
Color White
Electric Load Type Dimmable FluorescentDimmable LEDFluorescentIncandescentLED
Switch Type Push Button Illuminated
Security V2 S2_UNAUTHENTICATED ,S2_AUTHENTICATED
Frequency XXfrequency
Maximum transmission power XXantenna

Supported Command Classes

  • Association Grp Info
  • Association V2
  • Basic
  • Configuration V3
  • Device Reset Locally
  • Firmware Update Md V4
  • Manufacturer Specific V2
  • Powerlevel
  • Scene Activation
  • Scene Actuator Conf
  • Security 2
  • Supervision
  • Switch Multilevel V4
  • Transport Service V2
  • Version V3
  • Zwaveplus Info V2

Controlled Command Classes

  • Supervision

Explanation of Z-Wave specific terms

  • Controller — is a Z-Wave device with capabilities to manage the network. Controllers are typically Gateways,Remote Controls or battery operated wall controllers.
  • Slave — is a Z-Wave device without capabilities to manage the network. Slaves can be sensors, actuators and even remote controls.
  • Primary Controller — is the central organizer of the network. It must be a controller. There can be only one primary controller in a Z-Wave network.
  • Inclusion — is the process of adding new Z-Wave devices into a network.
  • Exclusion — is the process of removing Z-Wave devices from the network.
  • Association — is a control relationship between a controlling device and a controlled device.
  • Wakeup Notification — is a special wireless message issued by a Z-Wave device to announces that is able to communicate.
  • Node Information Frame — is a special wireless message issued by a Z-Wave device to announce its capabilities and functions.