This is a
2.Make sure the sensor is powered.
3.Set Z-Wave controller or Z-Wave gateway into inclusion mode (Refer to the controller or gateway operating manual)
4.Press the button three times within 1.5 second, the device will enter inclusion mode. And the LED will flash on and off alternately five times.
This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.
In the front casing, there is button that is used to carry out include, exclude or reset factory default settings on PCB Board.
When power is first supplied, the LED will flash on and off alternately at one second intervals within 5 seconds if the detector has not been added a Z-Wave network. Please get familiar with the terms below before starting the operations.
Reset to factory default | 1.Remove the device cover 2.Make sure the sensor is powered 3.Press and hold the button for 10 seconds 4.Release the button. |
Inclusion | Press the button three times within 1.5 second, the device will enter inclusion mode. And the LED will flash on and off alternately five times. |
Exclusion | Press the button three times within 1.5 second, the device will enter exclusion mode. |
NIF | XXXNIF |
Wakeup | Manual Wakeup the Sensor You can press the button once to wake up the device and send wakeup notification to controller. If press successfully, the LED will blink one time. |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | GROUP 1 is lifeline service that assigned to Sensor (Door/Window detector) status u2013 Open/Close. It enables the sensor to send reports and readings to Z-Wave Controller or Z-Wave Gateway whenever the sensor is triggered. This Group Support:NOTIFICATION_REPORT BATTERY_REPORT SENSOR_BINARY_REPORT DEVICE_RESET_LOCALLY_NOTIFICATION |
2 | 5 | GROUP 2 allows for sending control commands to associated devices such as relay module, lighting, etc. This association group is configured through the advanced parameters no. 1 and 2. This Group Support:BASIC_SET. |
3 | 5 | GROUP 3 allows for Send Notification to associated devices in this group. This Group Support: NOTIFICATION_REPORT |
4 | 5 | GROUP 4 allows for Send Notification to associated devices in this group. This Group Support: SENSOR_BINARY_REPORT |
This configuration parameter can be used to adjust the amount of delay before the OFF command is transmitted. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 65535 | Seconds |
Basic Set Command will be sent where contains a value when the door/window is opened or closed, Z-Wave controller or z-wave gateway will take it for consideration; for instance, if a lamp module receives the Basic Set Command of which value is decisive as to how bright of dim level of lamp module shall be. Size: 1 Byte, Default Value: 255
Setting | Description |
---|---|
0 | Alarm Off |
1 - 99 | Alarm cancelling |
255 | Alarm On |
Dimensions | 70 x 20 x 20 mm |
Weight | 16 gr |
Hardware Platform | ZM5202 |
EAN | 6924715900520 |
IP Class | IP 20 |
Battery Type | 1 * CR2 |
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Z-Wave Version | 6.51.06 |
Certification ID | ZC10-16055076 |
Z-Wave Product Id | 0x0258.0x0003.0x1082 |
Sensors | Open/Closed (Binary) |
Color | White |
Firmware Updatable | Updatable by Manufacturer |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |