Quickstart

This is a Touch Panal Switch for Europe. To run this device please connect it to your mains power supply.

To include or exclude the device you only need to press and hold any key for 3 seconds.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

What is Z-Wave?

Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.

Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.

This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.

If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.

For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.

Product Description

The MCO_TPS314 is a glass-surface wireless actuator able to to switch 4 separate oads up to 1100 W. It is designed for application in UK Pattress boxes (according to British Standard). Beside local switching the device can be used to control four groups of directly associated devices or scenes stored in the central controller. A blue LED on every button indicates the switching status. The installation of the device requires a 3 wire system with neutral wire.

Prepare for Installation / Reset

Please read the user manual before installing the product.

In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.

Reset to factory default

This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.

  • Press and hold any key on the panel for 10 seconds for restoring factory settings. 
  • Then the node information and association data will be deleted.
Noteï¼ÂÂÂÂÂÂ?If factory settings are restored, all INDICATION LEDs on the panel will turn orange, and all switches will turn off.

Safety Warning for Mains Powered Devices

ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.

Installation

Caution: The device is for British standard socket!

Important
: Please make sure you have cut off power supply before you start to install the Panel.

  1. Remove the steel frame from the device, and secure it onto the junctions box with tow screws.
  2. Insert all wires into the right terminals and tighten screws.
  3. Attach the wired device on "A" points of the steel frame as shown first, and then push the whole device into junction box.
  4. Confirm the device is well mounted, power on and it is ready to operate.

Inclusion/Exclusion

On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.

Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.

Inclusion

To include the device you only need to press and hold any key for 8 seconds.

Exclusion

To exclude the device you only need to press and hold any key for 8 seconds.

Product Usage

The actuator is operated by the local switching Touch pannels or wirelessly using Z-Wave commands.

Quick trouble shooting

Here are a few hints for network installation if things dont work as expected.

  1. Make sure a device is in factory reset state before including. In doubt exclude before include.
  2. If inclusion still fails, check if both devices use the same frequency.
  3. Remove all dead devices from associations. Otherwise you will see severe delays.
  4. Never use sleeping battery devices without a central controller.
  5. Dont poll FLIRS devices.
  6. Make sure to have enough mains powered device to benefit from the meshing

Association - one device controls an other device

Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.

Association Groups:

Group Number Maximum Nodes Description
1 5 Switch Button Group 1
2 5 Switch Button Group 2
3 5 Switch Button Group 3
4 5 Switch Button Group 4
5 1 This group supports one node, which defaults to controller node.

Technical Data

Dimensions 0.0860000x0.0860000x0.0340000 mm
Weight 190 gr
IP Class IP IP20
Voltage 230 V
Load 1150 W
Device Type Touch Panal Switch
Generic Device Class Binary Switch
Specific Device Class Binary Power Switch
Firmware Version 01.00
Z-Wave Version 03.67
Certification ID ZC08-14080012
Z-Wave Product Id 0x015f.0x0000.0x0000
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW

Supported Command Classes

Controlled Command Classes

Explanation of Z-Wave specific terms