Quickstart

This is a On/Off Power Switch for Europe. To run this device please connect it to your mains power supply. A This device is a Z-Wave Actuator. To include or exclude the device you only need to press and hold any key for 8 seconds.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

What is Z-Wave?

Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.

Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.

This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.

If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.

For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.

Product Description

The TPS411 by MCO Home is a wall switch with integrated switch relay. The relay can be controlled both with the touch switch, which is integrated into the glass surface, and via Z-Wave commands. The relay can switch a load with up to 1,100 watts.  Beside local switching the device can be used to control two groups of directly associated devices. A blue LED on every button indicates the switching status.

The wall switch can be easily connected to an electrical load without installing a flush mounted module separately. The relay is located inside a module which is directly connected to the glass touch button. With that MCO Home wall switch you can replace any switch insert or toggle switch. The wall switch can be mounted on any flush box.

With the stylish glass wall switches by MCO Home you can easily integrate your already installed lights into your home automation network. Without installing any news cable, you can switch your lighting as usual via wall switch – but thanks to Z-Wave technology also via remote control, smartphone or sensor-controlled automation. 

Prepare for Installation / Reset

Please read the user manual before installing the product.

In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.

Safety Warning for Mains Powered Devices

ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.

Installation

Important: Please make sure you have cut off power supply before you start to install the device.

  1. Remove the steel frame from the device, and secure it onto the junctions box with tow screws.
  2. Insert all wires into the right terminals and tighten screws.
  3. Attach the wired device on "A" points of the steel frame as shown first, and then push the whole device into junction box.
  4. Confirm the device is well mounted, power on and it is ready to operate.

Inclusion/Exclusion

On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.

Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.

Inclusion

To include the device you only need to press and hold any key for 8 seconds.

Exclusion

To exclude the device you only need to press and hold any key for 8 seconds.

Product Usage

The actuator is operated by the local switching Touch pannels or wirelessly using Z-Wave commands.

Scene Function:

1. Scene Response Device
As a Scene Response device, it supports “Scene Activation CC” and “Scene Actuator Conf
CC” ,which make the device can be added into any scene , and supports 255 Scene ID. In parameter
item 0x10, users can configure which external switch button will respond the scene CC.

2. Scene Activate Device
As a Scene Activate device, when pressing the switch button, it will send “Scene Activation” to
Association Group 1 (normally associated to the gateway) to activate corresponding scenes, and the
scene ID is set by configuration parameter. This function is disabled by default, to activate it, please
refer to the configuration parameter table item 17-19.

3. Central Scene Activate Device
As a Central Scene Activate device, it supports “Central Scene CC”. When pressing the switch
button, it will send “Central Scene Notification” to Association Group 1 (normally associated to
gateway). This function is always being activated and cannot be disabled.

Quick trouble shooting

Here are a few hints for network installation if things dont work as expected.

  1. Make sure a device is in factory reset state before including. In doubt exclude before include.
  2. If inclusion still fails, check if both devices use the same frequency.
  3. Remove all dead devices from associations. Otherwise you will see severe delays.
  4. Never use sleeping battery devices without a central controller.
  5. Dont poll FLIRS devices.
  6. Make sure to have enough mains powered device to benefit from the meshing

Association - one device controls an other device

Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.

Association Groups:

Group Number Maximum Nodes Description
1 1 Lifeline
2 5 Associate with Key 1 - send Basic Set Command to associated devices

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.

IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.

Parameter 2: Switch state saved or not when power failure


Size: 1 Byte, Default Value: 1

Setting Description
0 not saved,switch will be off when powered again
1 saved,switch will keep the same state when powered again

Parameter 3: ALL ON/ALL OFF


Size: 1 Byte, Default Value: 255

Setting Description
0 forbid ALL ON, forbid ALL OFF
1 forbid ALL ON, allow ALL OFF
2 allow ALL ON, forbid ALL OFF
255 allow ALL ON, allow ALL OFF

Parameter 4: LED Backlit brightness level


Size: 1 Byte, Default Value: 10

Setting Description
0 LED disabled
1 - 10 Min level-Max level

Parameter 5: Key Mode

This function works for corridor or stairwell situation.
Size: 1 Byte, Default Value: 0

Setting Description
0 single click to switch on/off status
1 Key default as off state. When it is turned on, then it will be turned off automatically after a time period , which can be set in item 6
2 Key default as on state. When it is turned off, then it will be turned on automatically after a time period , which can be set in item 6
3 hold >3s then key is on, and off once released
4 single click to switch on/off status + hold >3s then key is on, and off once released

Parameter 6: Key On duration


Size: 2 Byte, Default Value: 0

Setting Description
0 infinite
1 - 65535 unit sec

Parameter 8: Basic CC integration setting

This parameter works for integration with different gateways/systems. If do not know how to use, pls keep as default.
Size: 1 Byte, Default Value: 0

Setting Description
0 Basic Set received,key 1 responds; Basic Get received,key 1 sends Basic Report; key 1 will not send unsolicited Basic Report(No Endpoint)to LifeLine Association
1 Basic Set received,key 1 responds; Basic Get received,key 1 sends Basic Report; key 1 will send unsolicited Basic Report(No Endpoint)to LifeLine Association
2 Basic Set received,all keys respond; Basic Get received,not reply Basic Report; All keys will not send unsolicited Basic Report(No Endpoint) to LifeLine Association
3 Basic Set received,all keys respond; Basic Get received,key 1 sends Basic Report; All keys will not send unsolicited Basic Report(No Endpoint)to LifeLine Association

Parameter 16: Scene respond


Size: 1 Byte, Default Value: 0

Setting Description
0 Scene respond disabled
1 Key1 respond scene

Parameter 17: Key1 Scene Activate Mode Setting


Size: 1 Byte, Default Value: 0

Setting Description
0 Scene activate function disabled
1 One click key1 always activate scene ID1 no matter what the status of key1 is.
2 One click key1,only activate scene ID1 when key1‘s relay output is open
3 One click key1,only activate scene ID1 when key1‘s relay output is close

Parameter 18: Key1 Activate Scene ID


Size: 1 Byte, Default Value: 00

Setting Description
0 Scene ID is invalid and will not send scene activate command.
1 - 255 Scene ID

Parameter 19: Key1 Activate Scene Duration


Size: 1 Byte, Default Value: 0

Setting Description
0 Instantly
1 - 127 Dimming durations from 1 second to 127 seconds in 1-second resolution
128 - 254 Specify dimming durations from 1 minute to 127 minutes in 1-minute resolution.

Parameter 255: Factory Reset


Size: 1 Byte, Default Value: 0

Setting Description
85 Factory Reset

Technical Data

Dimensions 86 x 86 x 39 mm
Weight 180 gr
Hardware Platform ZM5101
EAN 4251295700762
IP Class IP 20
Voltage 230 images/manufacturers/MCO_Home.png
Load 5A
Device Type On/Off Power Switch
Generic Device Class Binary Switch
Specific Device Class Binary Power Switch
Firmware Version 05.02
Z-Wave Version 04.3e
Z-Wave Product Id 0x015f.0x4111.0x5102
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW

Supported Command Classes

  • Basic
  • Switch Binary
  • Switch All
  • Scene Activation
  • Scene Actuator Conf
  • Association Grp Info
  • Device Reset Locally
  • Central Scene
  • Zwaveplus Info
  • Multi Channel
  • Configuration
  • Manufacturer Specific
  • Powerlevel
  • Firmware Update Md
  • Association
  • Version
  • Multi Channel Association
  • Switch Multilevel
  • Transport Service

Controlled Command Classes

  • Basic
  • Central Scene
  • Switch Multilevel
  • Transport Service

Explanation of Z-Wave specific terms

  • Controller — is a Z-Wave device with capabilities to manage the network. Controllers are typically Gateways,Remote Controls or battery operated wall controllers.
  • Slave — is a Z-Wave device without capabilities to manage the network. Slaves can be sensors, actuators and even remote controls.
  • Primary Controller — is the central organizer of the network. It must be a controller. There can be only one primary controller in a Z-Wave network.
  • Inclusion — is the process of adding new Z-Wave devices into a network.
  • Exclusion — is the process of removing Z-Wave devices from the network.
  • Association — is a control relationship between a controlling device and a controlled device.
  • Wakeup Notification — is a special wireless message issued by a Z-Wave device to announces that is able to communicate.
  • Node Information Frame — is a special wireless message issued by a Z-Wave device to announce its capabilities and functions.