This is a
Under normal working interface, long press S1+S3 to enter the Z-Wave Inclusion interface, the interface shows the current Node ID.
If shows "- - -‘‘ then means the device is not included in the network.
Short press S2, the device enter into learning mode, after learning mode is completed, the device shows Node ID.
MH3901-Z is a smart boiler thermostat, it can automatically detect the indoor temperature and display the relevant temperature value for boiler heating control. lt also can automatically turn on/off the heating system according to the temperature difference. The device can be remotely controlled by Z-Wave network.
Symbol | Description |
---|---|
Included in Z-Wave Network | |
not included | |
Output state is ON | |
Output Stat is OFF | |
Manual Mode | |
Energy Saving Mode | |
Semi-bright | |
Full-bright |
Under normal working interface, press S1 or S3 to modify the setting temperature, then press S2 as confirm or after 5sec without any operation, it will be back to the normal working interface. The temperature setting range is 5-37 °C
Reset to factory default | XXXResetDescription |
Inclusion | Under normal working interface, long press S1+S3 to enter the Z-Wave Inclusion interface, the interface shows the current Node ID. If shows "- - -‘‘ then means the device is not included in the network. Short press S2, the device enter into learning mode, after learning mode is completed, the device shows Node ID. |
Exclusion | Under normal working interface, long press S1+S3 to enter the Z-Wave Exclusion interface, the interface shows the current Node ID Short press S2 and the device enters into learning mode, after learning mode is completed, the device shows "- - -" |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Lifeline |
2 | 5 |
Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Disabled |
1 | Differential reporting |
2 | Regular reporting |
3 | Differential reporting + interval reporting |
Size: 2 Byte, Default Value: 5
Setting | Description |
---|---|
3 - 995 | Setting the temperature difference |
Size: 2 Byte, Default Value: 60
Setting | Description |
---|---|
10 - 32767 | Steps: 1 second |
Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
0 | Do not send |
1 - 127 | Quantity |
Size: 1 Byte, Default Value: 20
Setting | Description |
---|---|
10 - 120 | Setting the heating time in minutes |
Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
10 - 120 | The heating time should be less than the P07 value in minutes. |
Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
17185 | Restore complex default parameters |
39030 | Restore factory settings |
Dimensions | 104 x 104 x 20 mm |
Hardware Platform | SD3502 |
EAN | 6928954250002 |
IP Class | IP 20 |
Voltage | 9 - 24V |
Load | 0,5 A |
Firmware Version | 02.02 |
Z-Wave Version | 06.07 |
Z-Wave Product Id | 0x015f.0x3902.0x5102 |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |