Quickstart

This is a secure Alarm Sensor for CEPT (Europe). Please make sure the internal battery is fully charged. To add this device to your network execute the following action:
-Click [Add] icon in Z-Wave Controller .-Press the Net_Button 3 times within 1.5s, Green LED is Blinking 3 times within 1 second.-If Inclusion Process is successful, Green led will turn off.

Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.


Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

What is Z-Wave?

Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.

Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.

This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.

If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.

For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.

Product Description

The Smart Smoke Alarm adopts Z-Wave protocol, when the sensor detects smoke to the set level, it will issueacoustic-optic alarm to alert the users and also send alarm notifications to gateway immediately.It's suitable to be installed in living room, office,warehouse,and etc.

Prepare for Installation / Reset

Please read the user manual before installing the product.

In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.

Reset to factory default

This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.

--Long press Net_Button while installing batteries in the product.- Device Reset Locally notification is Transmitted.Please use this procedure only when the network primary controller is missing or otherwise inoperable.

Inclusion/Exclusion

On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.

Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.

Inclusion

-Click [Add] icon in Z-Wave Controller .-Press the Net_Button 3 times within 1.5s, Green LED is Blinking 3 times within 1 second.-If Inclusion Process is successful, Green led will turn off.

Exclusion

-Click [Remove] icon in Z-Wave Controller-Press the Net_Button 3 times within 1.5s -If Exclusion Process is successful, Green led is Blinking 6 times, then turn off.

Quick trouble shooting

Here are a few hints for network installation if things dont work as expected.

  1. Make sure a device is in factory reset state before including. In doubt exclude before include.
  2. If inclusion still fails, check if both devices use the same frequency.
  3. Remove all dead devices from associations. Otherwise you will see severe delays.
  4. Never use sleeping battery devices without a central controller.
  5. Dont poll FLIRS devices.
  6. Make sure to have enough mains powered device to benefit from the meshing

Association - one device controls an other device

Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.

Association Groups:

Group Number Maximum Nodes Description
1 5 This is Lifeline association group, Including command classes: Battery report, Notification report, and Device Reset Locally notification
2 5 This is Root Device group,The Sensor sends a Basic Set command to directly trigger devices (like a light, switch, etc.) in response to events. The value of the Basic Set command (e.g. Siren trigger) is configured usingsmoke or no smoke.

Technical Data

Hardware Platform ZM5202
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Firmware Version HW: 255 FW: 3.01
Z-Wave Version 6.71.03
Certification ID ZC10-18076198
Z-Wave Product Id 0x0260.0x8002.0x1000
Color White
Firmware Updatable Updatable by Manufacturer
Communications Protocol Z-Wave Serial API
Supported Notification Types Emergency AlarmSmoke Alarm
Security V2 S2_UNAUTHENTICATED
Frequency XXfrequency
Maximum transmission power XXantenna

Supported Command Classes

Controlled Command Classes

Explanation of Z-Wave specific terms