This is a
Heatit Z-TRM2fx is equipped with a single pole switch and it fits most System 55 frames (Elko RS16, Schneider Exxact, Gira, Jung etc.). The thermostat can withstand a load of max 13A /2900W at 230V. At higher loads the thermostat must control a contactor. The thermostat may be connected to two wired external sensors. The thermostat has the capacity of up to 8 associations (relays, wall plugs etc.).The thermostat is designed for electrical heating.
Reset to factory default | By pressing buttons Right and Center (down and confirm) for 20 seconds, the thermostat will perform a complete factory reset. |
Inclusion | Press Center (confirm) for 10 seconds. The display will show OFF. Press Right (down) 4 times till you see Con in the display. Start adding mode by pressing Center (confirm) button for approximately 2 seconds. |
Exclusion | Press Center (confirm) for 10 seconds. The display will show OFF. Press Right (down) 4 times till you see Con in the display. Start removing mode by pressing Center (confirm) button for approximately 2 seconds. |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Lifeline. (Normally used by the Z-Wave Controller) Sends: - Thermostat Setpoint Reports - Thermostat Mode Reports |
2 | 5 | Send Multilevel Sensor Reports. |
3 | 5 | Send Multilevel Sensor Reports. |
4 | 5 | Send Binary Switch Set commands representing the status of the internal relay. |
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Off |
1 | Heating mode |
2 | Cooling mode (not implemented) |
11 | Energy saving heating mode |
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | F-mode, floor sensor mode. |
3 | A2-mode, external room sensor mode |
4 | A2F-mode, external sensor with floor limitation |
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | 10K NTC. |
1 | 12K NTC |
2 | 15K NTC |
3 | 22K NTC |
4 | 33K NTC |
5 | 47K NTC |
Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
3 - 30 | 0.3°C - 3.0°C |
Size: 2 Byte, Default Value: 50
Setting | Description |
---|---|
50 - 400 | 5.0°C - 40.0°C |
Size: 2 Byte, Default Value: 400
Setting | Description |
---|---|
50 - 400 | 5.0°C - 40.0°C |
Size: 2 Byte, Default Value: 50
Setting | Description |
---|---|
50 - 400 | 5.0°C - 40.0°C |
Size: 2 Byte, Default Value: 400
Setting | Description |
---|---|
50 - 400 | 5.0°C - 40.0°C |
Size: 2 Byte, Default Value: 210
Setting | Description |
---|---|
3 - 30 | 0.3°C - 3.0C |
50 - 400 | 5.0°C - 40.0°C |
Size: 2 Byte, Default Value: 180
Setting | Description |
---|---|
50 - 400 | 5.0°C - 40.0°C. |
Size: 2 Byte, Default Value: 210
Setting | Description |
---|---|
50 - 400 | 5.0°C - 40.0°C |
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 40 | 0 - 4.0°C. |
215 - 255 | -4,0 - -0,1°C |
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 40 | 0 - 4.0°C. |
215 - 255 | -4,0 - -0,1°C |
Selects which temperature is shown on the display. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Display setpoint temperature |
1 | Display measured temperature |
Configure the brightness of the buttons, in dimmed state. Size: 1 Byte, Default Value: 50
Setting | Description |
---|---|
0 - 100 | in % |
Configure the brightness of the buttons, in active state. Size: 1 Byte, Default Value: 100
Setting | Description |
---|---|
0 - 100 | in % |
Configure the brightness of the display, in dimmed state. Size: 1 Byte, Default Value: 50
Setting | Description |
---|---|
0 - 100 | in % |
Configure the brightness of the display, in active state. Size: 1 Byte, Default Value: 100
Setting | Description |
---|---|
0 - 100 | in % |
Time interval between consecutive temperature reports. Temperature reports can be also sent as a result of polling. Size: 2 Byte, Default Value: 60
Setting | Description |
---|---|
0 | Reporting of temperatures disabled |
30 - 32767 | in seconds |
The temperature report will be sent if there is a difference in temperature value from the previous value reported, defined in this parameter (hysteresis). Temperature reports can be also sent as a result of polling. Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
1 - 100 | 0.1°C - 10.0°C |
Time interval between consecutive meter reports. Meter reports can be also sent as a result of polling. Size: 2 Byte, Default Value: 60
Setting | Description |
---|---|
0 | Reporting of metering values is disabled |
30 - 32767 | in seconds |
Delta value in kWh between consecutive meter reports. Meter reports can be also sent as a result of polling. Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
0 - 127 | A delta value of 0 - 12.7 kWh will result in a metering report. |
Dimensions | 86,5 x 51,75 x 86,5 mm |
Hardware Platform | ZM5101 |
EAN | 7071236013495 |
IP Class | IP IP 20 |
Voltage | 230 V |
Load | 13 A |
Device Type | Thermostat - HVAC |
Network Operation | Always On Slave |
Firmware Version | HW: 2 FW: 3.03:03.02 |
Z-Wave Version | 6.71.03 |
Certification ID | ZC10-18116305 |
Z-Wave Product Id | 0x019B.0x0003.0x0202 |
IP (Ingress Protection) Rated | ok |
Neutral Wire Required | ok |
Sensors | HeatTarget TemperatureVoltageWater Temperature |
Color | White |
Thermostat Modes | AutoAwayCoolEnergy Save HeatHeat |
Supported Meter Type | Electric Energy |
Thermostat HVAC Systems Supported | Cool OnlyHeat OnlySimple Relay |
Thermostat Power Source | Mains powered (120V/240V) |
Firmware Updatable | Updatable by Consumer by RF |
Supported Notification Types | Heat Alarm |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |