This is a
The remote control is a Z-Wave device that can both control other Z-Wave devices and activate scenes in Gateways. Although it is controlling other devices, the device cannot act as Z-Wave network controller (primary or secondary) and will always need a Z-Wave network controller to be added into the aZ-Wave network. The remote control has the following functions:
1. Control of groups of other Z-Wave devices using ON, OFF and Dim commands.
2. Activation of scenes in Gateway mode.
Reset to factory default | Press and hold down both buttons I and O of Group 2 for a minimum of 10 seconds until the LED indicator turns on and then blinks 4 times quickly to indicate successful factory reset. |
Inclusion | Press and hold down both buttons I and O of Group 2 for 3 seconds. The LED indicator turns on, the Push Button will be set to adding mode, and stand by to be added to the network.
After 10s the LED indicator blinks 6 times quickly to indicate that the addition has been successful. |
Exclusion | Press and hold down both buttons I and O of Group 2 for 3 seconds, LED indicator turns on, the Push Button will be set to removing mode, and stand by to be removed. After 7s the LED indicator blinks 4 times quickly to indicate successful removal. |
NIF | Press and hold down both I- and O-buttons of Group 2 for 3 seconds. |
Wakeup | Push any button once to activate the Push Button for 3s, and press and hold down both the I- and O-buttons of Group 2 for 1 second to activate the Push Button for 7s. |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | 1. Send Command Class Device Reset Locally Notication V1 toassociated devices of this group to report factory reset information when factory reset the Push Button.2. When Push Button battery power value changes, send Command ClassBattery Report V1 to associated devices of this group to report power value information.3. Push once or press and hold any button to send scene activationcommand to the associated devices of this group using Command ClassCentral Scene Notication V3 |
2 | 5 | Push I-/O-button of Group 2 once to send ON/OFF command to associated devices of this group using Command Class Basic Set V2.Press and hold down I-/O-button of Group 2 to send light intensityincrease/decrease command to associated devices of this group usingCommand Class Multilevel V4. |
3 | 5 | Push I-/O-button of Group 3 oncetosend ON/OFF command to associateddevices of this group usingCommand Class Basic Set V2.Press and hold down I-/O-buttonof Group 3 to send light intensityincrease/decrease command toassociated devices of this group usingCommand Class Multilevel V4. |
Value=0x55AA, other values are invalid,factory reset the Remote Control Size: 2 Byte, Default Value: 21930
Setting | Description |
---|---|
21930 | factory reset |
Dimensions | 71,2 x 71,2 x 13,6 mm |
Weight | 60 gr |
Hardware Platform | ZM5101 |
EAN | 7071236015116 |
IP Class | IP 21 |
Voltage | 3V |
Battery Type | 1 * CR2450 |
Device Type | Wall Controller |
Network Operation | Portable Slave |
Z-Wave Version | 6.71.03 |
Certification ID | ZC10-20036898 |
Z-Wave Product Id | 0x019B.0x0300.0xa306 |
Z-Wave Scene Type | Central Scene |
Firmware Updatable | Updatable by Consumer by RF |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |