This Z-Wave module is used to regulate temperature. Regulation is done using full wave on/off technology. The module can be controlled either through Z-Wave network or through the wall switch. The module is designed to be mounted inside a “flush mounting box” and is hidden behind a traditional wall switch. Module measures power consumption of connected device. It is designed to act as repeater in order to improve range and stability of Z-Wave network.
- To prevent electrical shock and/or equipment damage, disconnect electrical power at the main fuse or circuit breaker before installation or any servicing.
- Make sure, that no voltage is present in the installation.
- Prevent the disconnecting device from being switched on accidentally.
- Connect the module according to electrical diagram.
- Locate the antenna far from metal elements (as far as possible).
- Do not shorten the antenna.
Functionality
To turn the module on or off the user can simply press once switch connected to I1 or by pressing on the button Auto in the GUI. When the module is turned on it automatically regulated the temperate based on Hysteresis on and Hysteresis off parameters settings. When the temperature is decreasing and reaches point 1 (defined by parameter 43), heating device is turned on and remains active until the temperature in the room is not increased to reach point 2 (defined by parameter 44). In this moment heating device is turned off. When heating device is turned off, then it is working in antifreeze regime. The antifreeze regime turns on heating device when the temperature is lower of equal to the temperature set by parameter 45.
Reset to factory default |
|
Inclusion |
|
Exclusion |
|
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Lifeline |
2 | 16 | Basic on/off (triggered at change of the output Q state and reflecting its state) |
3 | 16 | SENSOR_MULTILEVEL_GET (triggered once per minute if Parameter 121 is not 0) |
4 | 16 | Basic on/off (triggered by Too high temperature limit, it send FF) |
5 | 16 | THERMOSTAT_SETPOINT_GET (triggered once per minute if Parameter 121 is not 0) |
6 | 16 | Basic on/off (trigged by change of I1 if window sensor functionality is selected by parameter no. 11) |
7 | 16 | Basic on/off (trigged by change of I2 if condense sensor functionality is selected by parameter no. 12) |
8 | 16 | Basic on/off (trigged by change of I3 if flood sensor functionality is selected by parameter no. 13) |
9 | 16 | Sensor multilevel report (trigged by change of temperature) |
Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | mono-stable switch type (push button) |
1 | bi-stable switch type |
Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | mono-stable switch type (push button) |
1 | bi-stable switch type |
Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | mono-stable switch type (push button) |
1 | bi-stable switch type |
NOTE: This parameter has influence only when parameter no. 11 is set to the value “2”. After setting this parameter, switch the window sensor once, so that the module could determine the input state Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | NO (normally open) input type |
1 | NC (normally close) input type |
NOTE: This parameter has influence only when parameter no. 12 is set to the value “2000”. After setting this parameter, switch the condense sensor once, so that the module could determine the input state. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | NO (normally open) input type |
1 | NC (normally close) input type |
NOTE: This parameter has influence only when parameter no. 13 is set to the value “2”. After setting this parameter, switch the flood sensor once, so that the module could determine the input state. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | NO (normally open) input type |
1 | NC (normally close) input type |
Flush on/off thermostat module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system. Size: 2 Byte, Default Value: 255
Setting | Description |
---|---|
255 | ALL ON active, ALL OFF active. |
0 | ALL ON is not active, ALL OFF is not active |
1 | ALL ON is not active, ALL OFF active |
2 | ALL ON active, ALL OFF is not active |
Size: 2 Byte, Default Value: 1
Setting | Description |
---|---|
1 | input I1 changes the mode of the thermostat between Off and Heat/Cool. In this case function on window sensor is disabled |
2 | input I1 influences on heating/cooling valves according to status of window sensor. In this case function of Off and Heat/Cool selection by I1 is disabled |
32767 | input I1 doesn’t influence on the Heat/Cool process |
Size: 2 Byte, Default Value: 32676
Setting | Description |
---|---|
0 - 990 | Temperature set point from 0.0 °C to 99.0 °C. When I2 is pressed, it automatically set temperature setpoint according to value defined here. In this case function of condense sensor is disabled |
1001 - 1050 | Temperature set point from -0.1 °C to -15.0 °C. When I2 is pressed, it automatically set temperature setpoint according to value defined here. In this case function of condense sensor is disabled |
2000 | Input I2 influences on the cooling valve according to status of condense sensor, In this case function of setpoint selection with I2 is disabled |
32767 | input I2 does not influence on the Heat/Cool process |
NOTE: If this parameter is changed, it is necessary to reinclude the module. Size: 2 Byte, Default Value: 32767
Setting | Description |
---|---|
1 | input I3 changes the mode of the thermostat between Heat and Cool and override parameter 59. In this case function on flood sensor is disabled |
2 | input I3 influences on heating/cooling valves according to status of flood sensor. In this case function of Heat/Cool selection by I3 is disabled |
32767 | input I3 does not influence on the heat/cool process |
Set value means percentage, set value from 0 - 100=0% - 100%.
NOTE: if power changed is less than 1W, the report is not send (pushed), independent of percentage set.
Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
0 | reporting disabled |
1 - 100 | 1% - 100% Reporting enabled. Power report is send (push) only when actual power in Watts in real time changes for more than set percentage comparing to previous actual power in Watts, step is 1%. |
Set value means time interval (0 – 32767) in seconds, when power report is send. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 | reporting disabled |
1 - 32767 | 1 second - 32767 seconds. Reporting enabled. Power report is send with time interval set by entered value. Please note, that too fast reporting can cause too much Z-Wave traffic resulting in Z-Wave poor response |
This parameter defines temperature min difference between real measured temperature and set-point temperature to turn device on Size: 2 Byte, Default Value: 1005
Setting | Description |
---|---|
0 - 127 | 0.0 °C … 12.7 °C |
1001 - 1127 | -0.1°C ~ -12.7 °C |
This parameter defines temperature min difference between real measured temperature and set-point temperature to turn device off. Size: 2 Byte, Default Value: 5
Setting | Description |
---|---|
0 - 127 | 0.0 °C - 12.7 °C |
1001 - 1127 | -0.1 °C ~ -12.7 °C |
Set value means at which temperature the device will be turned on even if the thermostat was manually set to off.
NOTE: Antifreeze is activated only in heating mode and it uses hysteresis from Par.34 and Par.44
Size: 2 Byte, Default Value: 50
Setting | Description |
---|---|
0 - 127 | 0.0 °C - 12.7 °C |
1001 - 1127 | -0.1°C ~ -12.6 °C |
255 | Antifreeze functionality disabled |
If parameter changed it is necessary to re-include module. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Heat mode |
1 | Cool mode |
Too low temperature limit is set by entered value. In case is set value out of this range, module is changing set value automatically to default value Size: 2 Byte, Default Value: 50
Setting | Description |
---|---|
1 - 1000 | 0.1°C to 100.0°C, step is 0.1°C |
1001 - 1150 | -0.1°C to -15.0°C |
Too high temperature limit is set by entered value. In case the set value is out of this range, module is changing automatically set value to default value. Size: 2 Byte, Default Value: 700
Setting | Description |
---|---|
1 - 1000 | 0.1°C - 100.0°C, step is 0.1°C. |
Set value means the type of the device that is connected to the on/off output. The device type can be normally open (NO) or normally close (NC). Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | When system is turned off the output is 0 V |
1 | When system is turned off the output is 230 V |
If the value of parameter is different to 0, means that the Influence of this input to heating or cooling will react after inserted time. This parameter has influence only when the window sensor functionality is selected by the parameter no. 11.
NOTE: Device status on UI change immediately
Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
1 - 32000 | seconds |
If the value of parameter is different to 0, means that the Influence of this input to heating or cooling will react after inserted time. This parameter has influence only when the window sensor functionality is selected by the parameter no. 11.
NOTE: Device status on UI change immediately
Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
1 - 32000 | seconds |
If the value of parameter is different to 0, means that the Influence of this input to heating or cooling will react after inserted time. This parameter has influence only when the window sensor functionality is selected by the parameter no. 12.
NOTE: Device status on UI change immediately
Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
1 - 32000 | seconds |
If the value of parameter is different to 0, means that the Influence of this input to heating or cooling will react after inserted time. This parameter has influence only when the window sensor functionality is selected by the parameter no. 12.
NOTE: Device status on UI change immediately
Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
1 - 32000 | seconds |
If the value of parameter is different to 0, means that the Influence of this input to heating or cooling will react after inserted time. This parameter has influence only when the window sensor functionality is selected by the parameter no. 13.
NOTE: Device status on UI change immediately
Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
1 - 32000 | seconds |
If the value of parameter is different to 0, means that the Influence of this input to heating or cooling will react after inserted time. This parameter has influence only when the window sensor functionality is selected by the parameter no. 13.
NOTE: Device status on UI change immediately
Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
1 - 32000 | seconds |
Enabling I1 means that Endpoint (I1) will be present on UI. Disabling it will result in hiding the endpoint according to the parameter set value. Additionally, a Notification Type and Event can be selected for the endpoint.
NOTE1: After parameter change, first exclude module (without setting parameters to default value) and then re include the module!
NOTE2: When the parameter is set to value 9 the notifications are send for Home Security.
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Endpoint, I1 disabled |
1 | Home Security; Motion Detection, unknown location. |
2 | CO; Carbon Monoxide detected, unknown location. |
3 | CO2; Carbon Dioxide detected, unknown location. |
4 | Water Alarm; Water Leak detected, unknown location. |
5 | Heat Alarm; Overheat detected, unknown location |
6 | Smoke Alarm; Smoke detected, unknown location. |
9 | Sensor binary |
Enabling I2 means that Endpoint (I2) will be present on UI. Disabling it will result in hiding the endpoint according to the parameter set value. Additionally, a Notification Type and Event can be selected for the endpoint. Available configuration parameters (data type is 1 Byte DEC): Endpoint device type selection: - notification sensor (1 - 6):
NOTE1: After parameter change, first exclude module (without setting parameters to default value) and then re include the module!
NOTE2: When the parameter is set to value 9 the notifications are send for Home Security.
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Endpoint, I1 disabled |
1 | Home Security; Motion Detection, unknown location. |
2 | CO; Carbon Monoxide detected, unknown location. |
3 | CO2; Carbon Dioxide detected, unknown location. |
4 | Water Alarm; Water Leak detected, unknown location. |
5 | Heat Alarm; Overheat detected, unknown location |
6 | Smoke Alarm; Smoke detected, unknown location. |
9 | Sensor binary |
Enabling I3 means that Endpoint (I3) will be present on UI. Disabling it will result in hiding the endpoint according to the parameter set value. Additionally, a Notification Type and Event can be selected for the endpoint. Available configuration parameters (data type is 1 Byte DEC): Endpoint device type selection: - notification sensor (1 - 6):
NOTE1: After parameter change, first exclude module (without setting parameters to default value) and then re include the module!
NOTE2: When the parameter is set to value 9 the notifications are send for Home Security.
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Endpoint, I1 disabled |
1 | Home Security; Motion Detection, unknown location. |
2 | CO; Carbon Monoxide detected, unknown location. |
3 | CO2; Carbon Dioxide detected, unknown location. |
4 | Water Alarm; Water Leak detected, unknown location. |
5 | Heat Alarm; Overheat detected, unknown location |
6 | Smoke Alarm; Smoke detected, unknown location. |
9 | Sensor binary |
Set value is added or subtracted to actual measured value by sensor. Size: 2 Byte, Default Value: 32536
Setting | Description |
---|---|
1 - 100 | value from 0.1 °C to 10.0 °C is added to actual measured temperature. |
1001 - 1100 | value from -0.1 °C to -10.0 °C is subtracted to actual measured temperature. |
If digital temperature sensor is connected, module reports measured temperature on temperature change defined by this parameter. Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
0 | reporting disabled |
1 - 127 | 0,1°C - 12,7°C, step is 0,1°C |
If digital temperature sensor is not connected, module can grab measured temperature from external secondary module. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | internal digital temperature sensor is mounted, setpoint is set by controller |
1 | (bit 0) temperature is grabbed from external always on sensor with sensor_multilevel_get sent by association 3 |
2 | (bit 1) temperature is grabbed from external battery powered room sensor declared in parameter 122 |
3 | (bit 2) setpoint is grabbed from external always on module with thermostat_setpoint_get sent by association 5 |
8 | (bit 3) setpoint is grabbed from external battery powered room sensor declared in parameter 122. |
10 | (bit 1 and bit 3) temperature AND setpoint are grabbed from external battery powered room sensor declared in parameter 122 |
If digital temperature sensor is not connected, module can grab measured temperature from external battery powered room sensor defined by this parameter.
NOTE: Get sensor node_id from controller and set parameter 122 immediately after sensor weak up (after button press on it etc.)
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | external battery powered room sensor not in function |
1 - 254 | Node ID of external battery powered room sensor |
Dimensions | 0.0700000x0.0700000x0.0200000 mm |
Weight | 49.75 gr |
Hardware Platform | ZM5202 |
EAN | 3830062070133 |
IP Class | IP 20 |
Voltage | 230 V |
Load | 2300 W |
Firmware Version | 03.01 |
Z-Wave Version | 04.05 |
Z-Wave Product Id | 0x0159.0x0005.0x0051 |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |