NOTE: When connecting temperature sensor to module that has already been included, you have to exclude module first. Switch off power supply , connect the sensor and re-include the module.
Flush 2 relays module is used for switching on or off two electrical devices (e.g. lights, fans, etc ...). The module can be controlled either through Z-Wave network or through the wall switches.
The module is designed to be mounted inside a “flush mounting box”, hidden behind a traditional wall switch.
Module measures power consumption of two electrical devices and supports connection of digital temperature sensor. It is designed to act as repeater in order to improve range and stability of Z-wave network.
Reset to factory default | If the service button S is pressed for mor ethan 6 seconds the module will be reset to the factory defoult state |
Inclusion | • Press service button S for more than 2 second or press push button I1 three times within 3s (3 times change switch state within 3 seconds). |
Exclusion | • Press service button S for more than 6 second or press push button I1 five times within 3s ( 5 times change switch state within 3 seconds) in the first 60 seconds after the module is connected to the power supply. Note: By this function all parameters of the module are set to default values and own ID is deleted. If service button S is pressed more than 2 and less than 6second module is excluded, but configuration parameters are not set to default values |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Lifeline group (reserved for communication with the main controller). |
2 | 16 | basic on/off (triggered at change of the output Q1 state and reflecting its state) |
3 | 16 | switch binary report (triggered at change of the output Q1 state and reflecting its state) |
4 | 16 | power meter report (triggered at change of the output Q1 state) |
5 | 16 | basic on/off (triggered at change of the output Q2 state and reflecting its state) |
6 | 16 | switch binary report (triggered at change of the output Q2 state and reflecting its state) |
7 | 16 | power meter report (triggered at change of the output Q2 state) |
8 | 16 | multilevel sensor report (triggered at change of temperature sensor) |
Input 1 switch type Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | mono-stable switch type (push button) |
1 | bi-stable switch type |
Input 2 switch type Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | mono-stable switch type (push button) |
1 | bi-stable switch type |
Activate / deactivate functions ALL ON/ALL OFFFlush 2 relays module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system. Size: 2 Byte, Default Value: 255
Setting | Description |
---|---|
0 | ALL ON is not active ALL OFF is not active |
1 | ALL ON is not active ALL OFF active |
2 | ALL ON active ALL OFF is not active |
255 | ALL ON active, ALL OFF active |
When relay Q1 is ON it goes automatically OFF after time defined by this parameter. Timer is reset to zero each time the module receive ON command regardless from where it comes (push button, associated module, controller,..). Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Auto OFF disabled |
1 - 32535 | 1second (0,01s) - 32535 seconds (325,35s) Auto OFF enabled with define time, step is 1s or 10ms according to parameter nr.15 |
When relay Q1 is OFF it goes automatically ON after time defined by this parameter. Timer is reset to zero each time the module receive OFF command regardless from where it comes (push button, associated module, controller,..). Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Auto ON disabled |
1 - 32535 | 1second (0,01s) - 32536 seconds (325,35s) Auto ON enabled with define time, step is 1s or 10ms according to parameter nr.15 |
When relay Q2 is ON it goes automatically OFF after time defined by this parameter. Timer is reset to zero each time the module receive ON command regardless from where it comes (push button, associated module, controller,..). Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Auto OFF disabled |
1 - 32535 | 1second (0,01s) - 32535 seconds (325,35s) Auto OFF enabled with define time, step is 1s or 10ms according to parameter nr.15 |
When relay Q2 is OFF it goes automatically ON after time defined by this parameter. Timer is reset to zero each time the module receive OFF command regardless from where it comes (push button, associated module, controller,..). Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Auto ON disabled |
1 - 32535 | 1second (0,01s) - 32536 seconds (325,35s) Auto ON enabled with define time, step is 1s or 10ms according to parameter nr.15 |
Automatic turning off / on seconds or milliseconds selectionNote that parameter is valid for both outputs Q1, Q2 and is the same for turning off or on. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | seconds selected |
1 | milliseconds selected |
Saving the state of the relays Q1 and Q2 after a power failure Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Flush 2 relays module saves its state before power failure (it returns to the last position saved before a power failure) |
1 | Flush 2 relays module does not save the state after a power failure, it returns to "off" position. |
Set value means percentage, set value from 0 - 100 = 0% - 100%. Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
0 | Reporting Disabled |
1 - 100 | 1% - 100% Reporting enabled. Power report is send (push) only when actual power in Watts in real time changes for more than set percentage comparing to previous actual power in Watts, step is 1%. NOTE: if power changed is less than 1W, the report is not send (pushed), independent of percentage set. |
Set value means percentage, set value from 0 - 100 = 0% - 100% Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
0 | Reporting Disabled |
1 - 100 | 1% - 100% Reporting enabled. Power report is send (push) only when actual power in Watts in real time changes for more than set percentage comparing to previous actual power in Watts, step is 1%. NOTE: if power changed is less than 1W, the report is not send (pushed), independent of percentage set. |
Set value means time interval (0 - 32535) in seconds, when power report is send. Size: 2 Byte, Default Value: 300
Setting | Description |
---|---|
0 | Reporting Disabled |
1 - 32535 | = 1 second - 32535 seconds. Reporting enabled, Power report is send with time interval set by entered value. |
Set value means time interval (0 - 32535) in seconds, when power report is send. Size: 2 Byte, Default Value: 300
Setting | Description |
---|---|
0 | Reporting Disabled |
1 - 32535 | = 1 second - 32535 seconds. Reporting enabled, Power report is send with time interval set by entered value. |
Set value means the type of the device that is connected to the Q1 output. The device type can be normally open (NO) or normally close (NC). Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | When system is turned off the output is 0V (NC). |
1 | When system is turned off the output is 230V (NO). |
Set value means the type of the device that is connected to the Q2 output. The device type can be normally open (NO) or normally close (NC). Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | When system is turned off the output is 0V (NC). |
1 | When system is turned off the output is 230V (NO). |
Set value is added or subtracted to actual measured value by sensor. Size: 2 Byte, Default Value: 32536
Setting | Description |
---|---|
1 - 100 | value from 0.1 deg.C to 10.0 deg.C is added to actual measured temperature. |
1001 - 1100 | value from -0.1 deg.C to -10.0 deg.C is subtracted to actual measured temperature. |
32536 | offset is 0.0 deg.C |
If digital temperature sensor is connected, module reports measured temperature on temperature change defined by this parameter. Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
0 | Reporting disabled |
1 - 127 | 0,1 deg.C - 12.7 deg.C. - step is 0,1 deg.C |
Dimensions | 42x37x16 mm |
Weight | 28 gr |
Hardware Platform | ZM5202 |
EAN | 3830062070119 |
IP Class | IP 20 |
Voltage | 230 V |
Load | 2x 4A |
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Z-Wave Version | 6.51.06 |
Certification ID | ZC10-15100010 |
Z-Wave Product Id | 0x0159.0x0002.0x0051 |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |