This is a
Turn the primary controller of Z-Wave network into inclusion mode, short press the products Action button that you can find on the product's housing.
Oomi Plug is a low-cost Z-Wave Switch plug-in module specifically used to enable Z-Wave command and control (on/off) of any plug-in tool. It can report immediate wattage consumption or kWh energy usage over a period of time. In the event of power failure, non-volatile memory retains all programmed information relating to the units operating status.Its surface has a Smart RGB LED, which can be used for indicating the output load status or strength of the wireless signal. You can configure its indication colour according to your favour.The Plug is also a security Z-wave device and supports Over The Air (OTA) feature for the products firmware upgrade.
Reset to factory default | Press and hold the Action button that you can find on the product's housing for 20 seconds and then release. This procedure should only be used when the primary controller is inoperable. |
Inclusion | Turn the primary controller of Z-Wave network into inclusion mode, short press the products Action button that you can find on the product's housing. |
Exclusion | Turn the primary controller of Z-Wave network into exclusion mode, short press the products Action button that you can find on the product's housing. |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Group 1 is assigned to the Lifeline association group and every device has 5 nodes to associate.When the switch is turned on or off using the action button, the switch will send a basic report of its status to the nodes in association group 1. To change what kind of signal is sent to the nodes in group 1, please see the detailed description of configuration parameter 80. |
2 | 5 | When the product receives a controlling Basic Set CC/Switch Binary Set CC, which if cause the products load state to be changed, which will lead to send the Basic Set CC/Switch Binary Set CC to nodes in group 2. |
This parameter is used to configure which reports need to be sent in Report Group 1.The values corresponding to the first four bits of the parameter value may be combined to create different combinations of reports that you wish to have sent.For example, instantaneous Current is the value 2 and instantaneous Watts is the value 4, so setting parameter 101 to a value of 6 will result in both instantaneous Current and instantaneous Watts to be reported.See the full description of the parameter values for other possible settings. Size: 4 Byte, Default Value: 4
Setting | Description |
---|---|
8 | Report Accumulated kWh |
2 | Report Instantaneous Current (Amperes) |
4 | Report Instantaneous Watts |
1 | Report Instantaneous Voltage |
This parameter is used to configure which reports need to be sent in Report Group 2.The values corresponding to the first four bits of the parameter value may be combined to create different combinations of reports that you wish to have sent.For example, instantaneous Current is the value 2 and instantaneous Watts is the value 4, so setting parameter 102 to a value of 6 will result in both instantaneous Current and instantaneous Watts to be reported.See the full description of the parameter values for other possible settings. Size: 4 Byte, Default Value: 8
Setting | Description |
---|---|
1 | Report Instantaneous Voltage |
4 | Report Instantaneous Watts |
8 | Report Accumulated kWh |
2 | Report Instantaneous Current (Amperes) |
This parameter is used to configure which reports need to be sent in Report Group 3.The values corresponding to the first four bits of the parameter value may be combined to create different combinations of reports that you wish to have sent.For example, instantaneous Current is the value 2 and instantaneous Watts is the value 4, so setting parameter 103 to a value of 6 will result in both instantaneous Current and instantaneous Watts to be reported.See the full description of the parameter values for other possible settings. Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
4 | Report Instantaneous Watts |
8 | Report Accumulated kWh |
1 | Report Instantaneous Voltage |
2 | Report Instantaneous Current (Amperes) |
This parameter is used to set the interval time of sending report in Report Group 1. (The unit of time is second). Size: 4 Byte, Default Value: 600
Setting | Description |
---|---|
0 - 268435456 | Interval Seconds |
This parameter is used to set the interval time of sending report in Report Group 2. (The unit of time is second). Size: 4 Byte, Default Value: 600
Setting | Description |
---|---|
0 - 268435456 | Interval Seconds |
This parameter is used to set the interval time of sending report in Report Group 3. (The unit of time is second). Size: 4 Byte, Default Value: 600
Setting | Description |
---|---|
0 - 268435456 | Interval Seconds |
Configure the output load status after re-power on the Smart Switch. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | The output load status will be the same as the previous state before a power outage. |
1 | The output load status will be ON state after re-power on. |
2 | The output load status will be OFF state after re-power on. |
This parameter is used to configure the partner ID. (0== Aeon Labs Standard Product, 1~255== others). Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Aeon Labs Standard Product |
1 - 255 | Partner ID of Partner Product |
This parameter is used to enable/disable Lock all configuration parameters.(0 =disable, 1 = enable) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | All configuration parameters are configurable. |
1 | All configuration parameters are not configurable (Locked). |
This parameter is used to save the device tag, which will be written/ assigned in factory/ manufacturer. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 32767 | Device Tag |
This parameter is used to reset product to default factory setting. (There are just 2 values can be used). Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
1431655765 | Reset the product to default factory setting and be excluded from the Z-wave network. |
1 | Resets all configuration parameters to default setting. |
This parameter is used for the overload protection, which means the load will be disconnected after 2 minutes when the current more than 15.5A. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Overload Protection Disabled |
1 | Overload Protection is Enabled |
This parameter is only used for customer checking/testing the product's RGB color via changing the RGB values. Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 255 | Reserved |
255 - 65535 | Range of red color value. |
65536 - 16777215 | Range of green color value. |
16777215 - 2147483647 | Range of blue color value. |
This parameter is used to Enable/Disable to send notifications to associated devices (in Group 1) when the state of Smart Switch Gen5s load is changed. (0=Send nothing, 1=Send hail CC, 2=Send basic report CC). Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
2 | Send BASIC Report Command |
0 | Send Nothing (Disabled) |
1 | Send HAIL Command |
This parameter is used to configure the LED state when the Smart Switch is in Energy mode/Momentary indicate mode/Night light mode. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
1 | The state of LED will follow with the output load state, but will turn off after 5 seconds if there is no any switch action.(Momentary indicate mode) |
2 | The state of LED will the same with Night light mode state configured by parameter 83. |
0 | The state of LED will follow with the output load state(Energy mode) |
This parameter is used to configure the LED indication status when the current mode is Night light mode. Size: 4 Byte, Default Value: 14524637
Setting | Description |
---|---|
0 - 255 | Set the indication value of red Led. |
256 - 65535 | Set the indication value of green Led. |
65536 - 16777215 | Set the indication value of blue Led. |
This parameter is used to configure the brightness level for the LED indication.Brightness level range is 0 to 100%. Size: 1 Byte, Default Value: 50
Setting | Description |
---|---|
0 - 100 | Brightness level range is 0 to 100%. |
This parameter is used to Enable/Disable the function of parameter 91 and 92 (1=Enabled, 0=Disabled). Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Configuration Parameters 91 and 92 are Disabled |
1 | Configuration Parameters 91 and 92 are Enabled |
This parameter is used to induce an automatic report when the change of the current power is more/less than the threshold in wattage. Size: 2 Byte, Default Value: 25
Setting | Description |
---|---|
0 - 32767 | The threshold can be set from 0 to 32767 watt. |
This parameter is used to induce an automatic report when the change of the current power is more/less than the threshold in percentage. Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
0 - 100 | The threshold can be set from 0 to 100 percent. |
Hardware Platform | ZM5101 |
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 60 FW: 1.02 |
Z-Wave Version | 6.51.06 |
Certification ID | ZC10-15110005 |
Z-Wave Product Id | 0x016A.0x0103.0x0060 |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |