Quickstart

This is a Multiposition Motor Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply.

To include the device into the network, turn the controller into the inclusion mode and then press the Up or Down button of the device three times during 1.5 seconds. The LED will become green for 3 seconds and then turn off. The device is now ready to work.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

The Fibar Insert Motor Control allows controlling motors for jalousies and blinds both via Z-Wave wirelessly and locally utilizing a traditional wall switch. The device is placed in a wall box right behind the normal switch. The switch is not longer directly connected to the load but acts as input device for the Fibar insert that is controlling the load. The solution works with all switch design with or without neutral position as long as there is enough space in the wall box behind the switch. The device is just 15 mm height. The available space depends on the size of the traditional switch, the dimensions of the wall box and the amount of additional cabling placed in this box. This device is designed for a 3 wire system and needs a neutral wire in the wall box.

Installation

The motor control insert is designed to fit into standard circular European wall boxes with 60 mm diameter. With its 15 mm height, it can be also mounted behind traditional wall switches. This wall switch serves as an external control switch to controll loads. The relays are realized in the insert.

The inserts contacts N and L are connected directly with the mains distribution of the power network. The three wires of the motor are connected like shown in the figure below.

The motor control can be operated locally using a switching paddle installed on the wall box. To connect the switching paddle with the insert it has to be connected with the insert contacts S1, S2 and Sx. Attention: There must not be mains-power connected to the insert contacts. This would immediately lead to a destruction of the insert..

The local operation can be realized by a double switching paddle (bistable) or a double button (monostable). The connected switch type must be selected according to the inclusion by setting the configuration parameter 14. The local switch is connected with the motor control insert as shown in the schematics. If a bistable switch is connected it has to stay connected until the motor control insert is included into the Z-Wave network.

Attention: The switch insert has an automatic endposition identification. This requires that the insert is connected with a tube motor with endposition switches. A test operation without motor leads to a wrong behavior.

Product Usage

The shutter control insert allows you to control 230 V tubular motors. The actuator can directly be operated by the local switching paddle. If the switch is a conventional button, every button impulse will switch the device on or off. Using a switching paddle instead of a button the operation is the same with the exception that the switching paddle has to be switched back into the OFF status afterwards manually. One switching paddle of the double switch drives the motor in the one and the other paddle in the other end position.

The device is also able to report status changes to a controller (communication pattern 2) and to remotely operate other devices (communication pattern 5). The dimmer can be controlled by every Z-Wave device (communication pattern 1, 4 and 7). To operate other devices a second switch which does not operate the dimmer is needed.

Reset to factory default XXXResetDescription
Inclusion

Blinking red/green LED indicates that the device is in factory reset state. Once the controller is turned into inclusion mode tripple click one of the buttons on the device will include the device. A green blinking of LED will indicate successfull inclusion that will be turned off shortly afterwards. The device is excluded by tripple click to one of the buttons when the controller is in exclusion mode.

Exclusion

Blinking red/green LED indicates that the device is in factory reset state. Once the controller is turned into inclusion mode tripple click one of the buttons on the device will include the device. A green blinking of LED will indicate successfull inclusion that will be turned off shortly afterwards. The device is excluded by tripple click to one of the buttons when the controller is in exclusion mode.

NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
3 1
2 16 external Switch No 2
1 16 external Switch No 1

Configuration Parameters

Parameter 1: All on/off function

Enables or disabled the all on / all off function
Size: 1 Byte, Default Value: ff

Setting Description
00 neither ALL ON nor ALL OFF are active
01 only ALL OFF is active
02 only ALL ON is active
ff ALL ON and ALL OFF are active

Parameter 10: Turn Off Roller position function

activates the turn off roller positioning function
Size: 1 Byte, Default Value: 00

Setting Description
00 enabled
01 disabled

Parameter 14: Type of Switch

Defines the type of switch attached to the device
Size: 1 Byte, Default Value: 00

Setting Description
00 mono-stable switch
01 bi-stable switch

Parameter 20: Favorite position state

defines the favorite position of the blind
Size: 1 Byte, Default Value: 16

Setting Description

Parameter 30: General Alarm Set

This defines the behavior in case of general alarms
Size: 1 Byte, Default Value: 03

Setting Description
00 Deactivated, devices does not react to alarms
01 Blind will go down in case of alarm
02 Blind will go up in case of alarm

Parameter 31: Flood Alarm Set

This defines the behavior in case of flood alarms
Size: 1 Byte, Default Value: 02

Setting Description
00 Deactivated, devices does not react to alarms
01 Blind will go down in case of alarm
02 Blind will go up in case of alarm

Parameter 32: Smoke Alarm Set

This defines the behavior in case of smoke alarms
Size: 1 Byte, Default Value: 03

Setting Description
00 Deactivated, devices does not react to alarms
01 Blind will go down in case of alarm
02 Blind will go up in case of alarm

Parameter 33: Temperature Alarm Set

This defines the behavior of in case of temperature alarms
Size: 1 Byte, Default Value: 01

Setting Description
00 Deactivated, devices does not react to alarms
01 Blind will go down in case of alarm
02 Blind will go up in case of alarm

Technical Data

Dimensions 0.0420000x0.0370000x0.0160000 mm
Weight 26 gr
Hardware Platform ZM3102
EAN 5902020528036
Device Type Window Covering No Position/Endpoint
Generic Device Class Multilevel Switch
Specific Device Class Multiposition Motor Switch
Firmware Version 01.03
Z-Wave Version 03.14
Certification ID ZC08-11080006
Z-Wave Product Id 010f.0300.0103
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW
EuropeWindow Covering No Position/Endpoint