Quickstart

This is a Routing Binary Sensor for XXXQFrequencyName. To run this device please insert fresh 2 * AA batteries. To run this device please make sure the internal battery is fully charged.

Inclusion, Exclusion and wakeup are confirmed by three seconds clicking the tamper switch (Z-Wave Button) on the backside of the case.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

This sensor monitors leakage and sends an alarm when flooding or leakage is detected. The sensing device can be away up to 3 m from the main device. The unit can be mounted on every flat surface. The installation can be done with screws or double-sided tape.

The ST812 is a battery-powered device, which is in non-operating state unless an action is detected. After a programmable sleeping time the device wakes up and sends status information. After this the unit goes back to non-operating state. Batteries can be changed without unscrewing the device from the door or frame. The unit will give a visual warning on the device and sends a warning to the Z-Wave controller, when batteries need to be replaced. The units send information to a controller or any other associated Z-Wave device. Up to 4 devices can be controlled from this device.

The device needs to be included into a Z-Wave network by a remote control or any other Z- Wave controller. For configuration of certain behavior a static controller such as a PC with home automation software or a gateway is recommended.

Installation

1. Release the Sensor from the mounting plate and the battery cover by removing the fixing screws.

2. Put the 3 * AA 1.5V batteries in the battery compartment.

3. For mounting use mount plate and the screws.

4. Refit the device to the back cover and secure with the fixing screw.

A clean smooth surface is required to mount the Flood Detector securely. The length of flood sensor cable is 3 meters. If a 3-meter cable is too long, roll up the cable and fasten it by twist ties. The transceiver should be placed as high up as possible on the wall to improve communication and to prevent it from coming into contact with water in case of flooding.

Product Usage

  1. When water is detected, the orange LED of Detector will flash one second every one minute and beep 30 seconds and transmit radio signal to controller (option) simultaneously. In normal mode, the Detector is allowed to be activated once in one minute, avoiding false trigger.
  2. When water is released, the green LED on the Detector will illuminate once and emit radio signal to controller (option).
  3. When the battery level on the Detector drops to a certain level, the red LED will flash once every 30 seconds and radio signal will be transmitted to controller (option). Please follow the Battery Installation directions replacing the batteries as soon as red LED appears.

Reset to factory default XXXResetDescription
Inclusion

Make sure that your Z-Wave Controller is in the Inclusion-/Exclusion-Mode. Click three seconds on the tamper switch (Z-Wave Button) behind the mounting plate to confirm the process.

Exclusion

Make sure that your Z-Wave Controller is in the Inclusion-/Exclusion-Mode. Click three seconds on the tamper switch (Z-Wave Button) behind the mounting plate to confirm the process.

NIF

Click three seconds on the tamper switch (Z-Wave Button) behind the mounting plate or a detected action by the sensor sends a Node Information Frame.

Wakeup

Click three seconds on the tamper switch (Z-Wave Button) behind the mounting plate or a detected action by the sensor will wake up the device and keep it awake.

Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Devices controlled by open/close events

Technical Data

Dimensions 0.0850000x0.0850000x0.0390000 mm
Weight 170 gr
Hardware Platform ZM3102
EAN 4713616113212
Battery Type 2 * AA
Device Type Routing Binary Sensor
Generic Device Class Binary Sensor
Specific Device Class Routing Binary Sensor
Firmware Version 01.03
Z-Wave Version 02.40
Certification ID ZC08-09100002
Z-Wave Product Id 0086.0002.0004
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW
EuropeRouting Binary Sensor