Quickstart

This is a Door Lock Keypad for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
To add or include the danalock into a Z-Wave networkSet the controller in inclusion modeTouch the User Button until you hear two beeps.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

Z-Wave Controlled door lock with keypad, and Bluetooth Smart.Operated by Z-Wave.Connect Danalock to your Z-Wave gateway -Danalock interfaces with your existing Z-Wave network through the Danalock smartphone app.Operate Danalock remotely by accessing your Z-Wave network from anywhere in the world with internet access.

Reset to factory default The danalock can be set to factory settings by holding the User Button for ten beeps. Please use this procedure only when the primary controller is missing or otherwise inoperable.
Inclusion To add or include the danalock into a Z-Wave networkSet the controller in inclusion modeTouch the User Button until you hear two beeps.
Exclusion To remove or exclude the danalock into a Z-Wave networkSet the controller in exclusion modeTouch the User Button until you hear two beeps.
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 1 Z-Wave Plus Lifeline

Configuration Parameters

Parameter 1: Direction

0 = The motor goes clockwise when latched 1 = The motor goes counterclockwise when latched
Size: 1 Byte, Default Value: 0

Setting Description
0 The motor goes clockwise when latched
1 The motor goes counterclockwise when latched

Parameter 10: BrakeAndGoBack

0 = Disabled. 1-15 Seconds to brake. When used the lock will brake for x amount of seconds and then turn 75 degrees back. Made for special doors without door lever.(Only when unlatching).
Size: 1 Byte, Default Value: 0

Setting Description
0 Disabled
1 - 15 Seconds to brake. When used the lock will brake for x amount of seconds and then turn 75 degrees back. Made for special doors without door lever.(Only when unlatching).

Parameter 11: Async

0 = Async off, 1 = Async on. Used if the lock is using an optional rotation sensor. When async is enabled the lock will auto calibrate if already unlatched and asked to Unlatch again (used for special door locks where the key turn is asynced from the inside nob.)
Size: 1 Byte, Default Value: 0

Setting Description
0 Async off
1 Async on. Used if the lock is using an optional rotation sensor. When async is enabled the lock will auto calibrate if already unlatched and asked to Unlatch again (used for special door locks where the key turn is asynced from the inside nob.)

Parameter 12: Door lock operation report type

0 = Simple supported by all controllers that support door locks. 1 = Advanced, more specific reports through notification Command Class. 2 = No Door lock operation reports are sent unsolicited.
Size: 1 Byte, Default Value: 0

Setting Description
0 Simple supported by all controllers that support door locks.
1 Advanced, more specific reports through notification Command Class.
2 No Door lock operation reports are sent unsolicited.

Parameter 2: Speed (Torque)

1 = Slowest 2 = Slow 3 = Normal 4 = Fast 5 = Fastest
Size: 1 Byte, Default Value: 3

Setting Description
2 Slow
1 Slowest
3 Normal
4 Fast
5 Fastest

Parameter 3: Mode

0 = Stepper motor mode wave drive(power saving) 1 = Stepper motor mode full drive(Normal) 2 = Relay mode
Size: 1 Byte, Default Value: 1

Setting Description
1 Stepper motor mode full drive(Normal)
0 Stepper motor mode wave drive(power saving)
2 Relay mode

Parameter 4: Turn degrees

Factor 10 turn degrees ( 1 = 10 degrees, 9 = 90 degrees etc.)
Size: 1 Byte, Default Value: 9

Setting Description
1 - 100 Factor 10 turn degrees ( 1 = 10 degrees, 9 = 90 degrees etc.)

Parameter 5: Auto Latch time

How many seconds from the lock has been unlatched to it automatically should close again. If 0 then it is disabled.
Size: 1 Byte, Default Value: 0

Setting Description
0 - 60 How many seconds from the lock has been unlatched to it automatically should close again. If 0 then it is disabled.

Parameter 6: Sound

Disable or enable the beep sound from latch or unlatch operations(0 = Disable, 1 = Enable.)
Size: 1 Byte, Default Value: 1

Setting Description
0 Disable the beep sound from latch or unlatch operations
1 Enable the beep sound from latch or unlatch operations

Parameter 7: Battery Type

Set the type of battery that powers the device. This affects the returned battery state. 0 = 3,6 Volt battery, 1 = 3.0 Volt battery. 2 = Mains power, changing from and to mains power requires the Danalock to be excluded and included.
Size: 1 Byte, Default Value: 1

Setting Description
0 3,6 Volt battery
1 3.0 Volt battery.
2 Mains power, changing from and to mains power requires the Danalock to be excluded and included.

Parameter 8: Battery alarm value

When the battery level is equal to or under this value, the device will notify user with a beep sound after latch or unlatch.
Size: 1 Byte, Default Value: 0

Setting Description
0 - 100 When the battery level is equal to or under this value, the device will notify user with a beep sound after latch or unlatch.

Parameter 9: TurnAndGo

0 = Turn&Go off, 1 = Turn&Go on. Used if the lock is using a optional rotation sensor. Latch&Go on will turn automatically when manual turn is detected.
Size: 1 Byte, Default Value: 0

Setting Description
0 TurnAndGo off
1 TurnAndGo on will turn automatically when manual turn is detected.

Technical Data

Hardware Platform ZM5202
Device Type Door Lock Keypad
Network Operation Listening Sleeping Slave
Firmware Version 81
Z-Wave Version 6.51.03
Certification ID ZC10-15010004
Z-Wave Product Id 0x010E.0x0008.0x0001
Frequency XXfrequency
Maximum transmission power XXantenna
U.S. / Canada / MexicoDoor Lock Keypad