To add or include the danalock into a Z-Wave networkSet the controller in inclusion modeTouch the User Button until you hear two beeps.
Z-Wave Controlled door lock with keypad, and Bluetooth Smart.Operated by Z-Wave.Connect Danalock to your Z-Wave gateway -Danalock interfaces with your existing Z-Wave network through the Danalock smartphone app.Operate Danalock remotely by accessing your Z-Wave network from anywhere in the world with internet access.
Reset to factory default | The danalock can be set to factory settings by holding the User Button for ten beeps. Please use this procedure only when the primary controller is missing or otherwise inoperable. |
Inclusion | To add or include the danalock into a Z-Wave networkSet the controller in inclusion modeTouch the User Button until you hear two beeps. |
Exclusion | To remove or exclude the danalock into a Z-Wave networkSet the controller in exclusion modeTouch the User Button until you hear two beeps. |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Z-Wave Plus Lifeline |
0 = The motor goes clockwise when latched 1 = The motor goes counterclockwise when latched Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | The motor goes clockwise when latched |
1 | The motor goes counterclockwise when latched |
0 = Disabled. 1-15 Seconds to brake. When used the lock will brake for x amount of seconds and then turn 75 degrees back. Made for special doors without door lever.(Only when unlatching). Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disabled |
1 - 15 | Seconds to brake. When used the lock will brake for x amount of seconds and then turn 75 degrees back. Made for special doors without door lever.(Only when unlatching). |
0 = Async off, 1 = Async on. Used if the lock is using an optional rotation sensor. When async is enabled the lock will auto calibrate if already unlatched and asked to Unlatch again (used for special door locks where the key turn is asynced from the inside nob.) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Async off |
1 | Async on. Used if the lock is using an optional rotation sensor. When async is enabled the lock will auto calibrate if already unlatched and asked to Unlatch again (used for special door locks where the key turn is asynced from the inside nob.) |
0 = Simple supported by all controllers that support door locks. 1 = Advanced, more specific reports through notification Command Class. 2 = No Door lock operation reports are sent unsolicited. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
1 | Advanced, more specific reports through notification Command Class. |
2 | No Door lock operation reports are sent unsolicited. |
0 | Simple supported by all controllers that support door locks. |
1 = Slowest 2 = Slow 3 = Normal 4 = Fast 5 = Fastest Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
1 | Slowest |
2 | Slow |
3 | Normal |
4 | Fast |
5 | Fastest |
0 = Stepper motor mode wave drive(power saving) 1 = Stepper motor mode full drive(Normal) 2 = Relay mode Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Stepper motor mode wave drive(power saving) |
1 | Stepper motor mode full drive(Normal) |
2 | Relay mode |
Factor 10 turn degrees ( 1 = 10 degrees, 9 = 90 degrees etc.) Size: 1 Byte, Default Value: 9
Setting | Description |
---|---|
1 - 100 | Factor 10 turn degrees ( 1 = 10 degrees, 9 = 90 degrees etc.) |
How many seconds from the lock has been unlatched to it automatically should close again. If 0 then it is disabled. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 60 | How many seconds from the lock has been unlatched to it automatically should close again. If 0 then it is disabled. |
Disable or enable the beep sound from latch or unlatch operations(0 = Disable, 1 = Enable.) Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
1 | Enable the beep sound from latch or unlatch operations |
0 | Disable the beep sound from latch or unlatch operations |
Set the type of battery that powers the device. This affects the returned battery state. 0 = 3,6 Volt battery, 1 = 3.0 Volt battery. 2 = Mains power, changing from and to mains power requires the Danalock to be excluded and included. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
2 | Mains power, changing from and to mains power requires the Danalock to be excluded and included. |
0 | 3,6 Volt battery |
1 | 3.0 Volt battery. |
When the battery level is under this value, the device will notify user with a beep sound after latch or unlatch. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 100 | When the battery level is under this value, the device will notify user with a beep sound after latch or unlatch. |
0 = Turn&Go off, 1 = Turn&Go on. Used if the lock is using a optional rotation sensor. Latch&Go on will turn automatically when manual turn is detected. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | TurnAndGo off |
1 | TurnAndGo on will turn automatically when manual turn is detected. |
Hardware Platform | ZM5202 |
Device Type | Door Lock Keypad |
Network Operation | Listening Sleeping Slave |
Firmware Version | 82 |
Z-Wave Version | 6.51.03 |
Certification ID | ZC10-15010006 |
Z-Wave Product Id | 0x010E.0x0008.0x0002 |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |