Quickstart

This is a Portable Remote Controller for XXXQFrequencyName. To run this device please insert fresh 2 * AAAA batteries. To run this device please make sure the internal battery is fully charged.

2 seconds pressing the "Include" button will include this device into a Z-Wave network. Triple click on either the button "Down" or the button "Up" will issue a Node Information Frame and keep the device awake for 2 sec afterwards.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

This Duwi Wall Controller is a single paddle controller to control other Z-Wave devices such as dimmers, switches or window blinds. The unit has dedicated buttons for inclusion, exclusion and association and is able to work as a primary controller. It is delivered completely with single frame and switching paddle for Duwi Everlux. The unit is battery powered and therefore can be mounted on every plain and clean place.

Installation

The device can be mounted on every flat surface either using two screws or strong double sides type. To access the devices base the switching paddle need to be removed. Below the switching paddle the device has three more network control buttons. Insert both the batteries (2 x LR8D425) into the battery case while paying attention to the indicated plus (+) / minus (-) poles. The wireless wall switch can now be mounted.

Attention: The electronic circuit of the wall-mounted switch can be damaged in the case of wrong insertion of batteries.

Product Usage

The Controller controls other devices with its switching paddle (communication pattern 6 and 7). The upper part of the paddle will issue an ON command, the lower part will issue an OFF command to a group of devices associated with this controller.

Reset to factory default

Press the button "Exclusion" for 6 seconds (LED starts blinking in all three colors) followed by a triple click of the UP or a triple click of the DOWN button. The LED will turn green for 3 seconds if the reset was successful and then turn off. If the reset failed or timed out the LED will shine red.

Inclusion

Once the primary controller is turned into inclusion mode 2 seconds pressing the "Include" button will include this device into the primary controllers network. A green blinking of LED will indicate successfull inclusion that will be turned off shortly afterwards.

Exclusion

Once the primary controller is turned into inclusion mode 2 seconds pressing the "Include" button will include this device into the primary controllers network. A green blinking of LED will indicate successfull inclusion that will be turned off shortly afterwards.

NIF

Triple click on either the button

Wakeup

The device can be waken up manually by tripple pressing the paddle. Attention. Wakeup period is very short (1s)

Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation
  1. Triple click "Association" button.
  2. Single click the UP Button
  3. Issue a Node Information Frame from the target device. This is usually done by single or triple click a button. Please refer to the manual of this device how to issue a NIF.

Association Groups:

Group Number Maximum Nodes Description
1 5 Basic On/Off Group

Special Operations as Z-Wave Controller

As long as this device is not included into a Z-Wave network of a different controller it is able to manage its own Z-Wave network as primary controller. As a primary controller the device can include and exclude other devices in its own network, manage associations, and reorganize the network in case of problems. The following controller functions are supported:

Inclusion of other devices

Communication between two Z-Wave devices only works if both belong to the same wireless network. Joining a network is called inclusion and is initiated by a controller. The controller needs to be turned into the inclusion mode. Once in this inclusion mode the other device needs to confirm the inclusion - typically by pressing a button.

If current primary controller in your network is in special SIS mode this and any other secondary controller can also include and exclude devices.

To become primary a contoller have to be resetted and then include a device.

  1. Triple click the button "Inclusion". The LED will start blinking green. The controller is now in the inclusion mode and ready to include devices into its own network.
  2. Confirm the inclusion on the device that shall be included. Please refer to the manual of the device for more information on the inclusion process of this device.
  3. A successful inclusion is indicated by a green LED for 3 seconds. A failed or timed out inclusion is indicated by a red LED.

If inclusion of a new device fails, exclude it first from its previous network or reset it.

Exclusion of other devices

The primary controller can exclude devices from the Z-Wave network. During exclusion the relationship between the device and the network of this controller is terminated. No communication between the device and other devices still in the network can happen after a successful exclusion. The controller needs to be turned into the exclusion mode. Once in this exclusion mode the other device needs to confirm the exclusion - typically by pressing a button.

Attention: Removing a device from the network means that it is turned back into factory default status. This process can also exclude devices from it's previous network.

  1. Triple click the button "Exclusion". The LED will start blinking. Now the controller is in the exclusion mode.
  2. Press the button on the device to be excluded or refer to manual of this device on how to exclude this device.
  3. The LED will turn green for 3 seconds if the exclusion was successful and then turn off. If the exclusion failed or timed out the LED will turn red.

Attention: Removing a device from the network means that it is turned back into factory default status. This process can also exclude devices from its previous network.

Shift of Primary Controller Role

The device can hand over its primary role to another controller and become secondary controller.

The primary shift is initiated on the device by pressing the Association button for 6 seconds (LED blinks yellow) followed by pressing the include button for three seconds (LED blinks green). Now the new primary controller needs to be turned into the inclusion mode. Pushing UP or DOWN terminates the primary shift.

Technical Data

Dimensions 0.0710000x0.0710000x0.0110000 mm
Weight 19 gr
Hardware Platform ZM3102
Battery Type 2 * AAAA
Device Type Remote Control - Simple
Generic Device Class Portable Controller
Specific Device Class Portable Remote Controller
Firmware Version 00.00
Z-Wave Version 00.00
Certification ID ZC08-08100014
Z-Wave Product Id 0064.5002.0000
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW
EuropeRemote Control - Simple