This is a
2. Pressing the tamper key three times within 1.5 seconds to enter the inclusion mode.
3. After add successful, the device will wake to receive the setting command from Z-Wave Controller about 20 seconds.
MT02755 has temperature and humidity,based on Z-Waveâ„¢ technology. It is the Z-Wave plus product, it support the security, OTA... Those newest features of the Z-Wave technology. Z-Wave is a wireless communication protocol designed for home automation, specifically to remotely control applications in residential and light commercial environments. The technology uses a low-power RF radio embedded or retrofitted into home electronics devices and systems, such as lighting, home access control, entertainment systems and household appliances. This product can be included and operated in any Z-Waveânetwork with other Z-Wave certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.
Reset to factory default | 1. Pressing tamper key four times within 1.5 seconds and do not release the tamper key in the 4 th pressed, and the LED will light ON. 2. After 3 seconds the LED will turn OFF, after that within 2 seconds, release the tamper key. If successful, the LED will light ON one second. Otherwise, the LED will flash once. 3. IDs are excluded and all settings will reset to factory default. |
Inclusion | Pressing the tamper key three times within 1.5 seconds to enter the inclusion mode. |
Exclusion | Pressing tamper key three times within 1.5 seconds to enter the exclusion mode. Node ID has been excluded. |
NIF | XXXNIF |
Wakeup | When the device power on, the device will wake about 20 seconds. In this duration, the controller can communicate with the device. Normally the device is always sleeping to save the battery energy. |
Protection | XXXProtection |
FirmwareUpdate | The device support the Z-Wave firmware update via OTA. Let the controller into the firmware update mode, and then press the tamper key once to start the update. After finish the firmware download, the LED will start flash in every 0.5 second. At that time, please don‘t remove the battery , otherwise it will cause the firmware broken, and the device will no function. After the LED stop flash, it is recommended that the user power up the device. Caution: After remove the battery, please wait about 30 seconds, and then re-install the battery. |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 8 | Z-Wave Plus Lifeline |
Operation mode. Using bit to control.Bit0: Disable the Flood function.Bit1: Reserve.Bit2: Reserve.Bit3: Setting the temperature scale. 0: Fahrenheit, 1:CelsiusBit4: Reserve.Bit5: Disable the temperature report after event triggered. (1:Disable, 0:Enable)Bit6: Reserve.Bit7: Reserve. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
1 | Disable the Flood function. |
8 | Setting the temperature scale. 0: Fahrenheit, 1:Celsius |
32 | Disable the temperature report after event triggered. (1:Disable, 0:Enable) |
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
8 | Disable send out BASIC OFF after the flood event cleared. (1:Disable, 0:Enable) |
16 | Notification Type, 0: Using Notification Report. 1: Using Sensor Binary Report. |
32 | Disable Multi CC in auto report. (1:Disable, 0:Enable) |
64 | Disable to report battery state when the device triggered. (1:Disable, 0:Enable) |
The interval time for auto report the battery level. 0 means turn off auto report.The default value is 12. The tick time can setting by the configuration No.20. Size: 1 Byte, Default Value: 18
Setting | Description |
---|---|
0 - 127 | The interval time for auto report the battery level. |
The interval time for auto report the temperature. 0 means turn off auto report.The default value is 12. The tick time can setting by the configuration No.20. Size: 1 Byte, Default Value: 18
Setting | Description |
---|---|
0 - 127 | The interval time for auto report the temperature. |
The interval time for auto report the humidity. 0 means turn off auto report.The default value is 12. The tick time can setting by the configuration No.20. Size: 1 Byte, Default Value: 18
Setting | Description |
---|---|
0 - 127 | The interval time for auto report the humidity. |
The interval time for auto report each tick. Setting this configuration will effect configuration No.10, No.13, No.14 and No.15.Units of one minute.Caution1: Setting to 0 means turn off all auto report function.Caution2: The value is unsigned byte Size: 1 Byte, Default Value: 30
Setting | Description |
---|---|
0 - 255 | The interval time for auto report each tick. |
The temperature differential to report.0 means turn off this function. The unit is Fahrenheit.Enable this function the device will detect every 10 seconds. And when the temperature is over 140 degree Fahrenheit, it will continue report. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 - 127 | The temperature differential to report. 0 means turn off this function. |
The humidity differential to report.0 means turn off this function. The unit is percentage.Enable this function the device will detect every 10 seconds. Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
0 - 60 | The humidity differential to report. |
Dimensions | 28x86x23 mm |
Weight | 20 gr |
Hardware Platform | SD3502 |
EAN | 4250059696631 |
IP Class | IP 20 |
Battery Type | 1 * CR123A |
Device Type | Multilevel Sensor |
Network Operation | Reporting Sleeping Slave |
Z-Wave Version | 6.51.06 |
Certification ID | ZC10-17035463 |
Z-Wave Product Id | 0x0175.0x0002.0x0020 |
Sensors | Air TemperatureHumidity |
Color | White |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |