Quickstart

This is a secure Multilevel Sensor for XXXQFrequencyName. To run this device please insert fresh 1 * CR123A batteries. To run this device please make sure the internal battery is fully charged. 1. Have Z-Wave Controller entered inclusion mode.
2. Pressing the tamper key three times within 1.5 seconds to enter the inclusion mode.
3. After add successful, the device will wake to receive the setting command from Z-Wave Controller about 20 seconds.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

MT02755 has temperature and humidity,based on Z-Waveâ„¢ technology. It is the Z-Wave plus product, it support the security, OTA... Those newest features of the Z-Wave technology. Z-Wave is a wireless communication protocol designed for home automation, specifically to remotely control applications in residential and light commercial environments. The technology uses a low-power RF radio embedded or retrofitted into home electronics devices and systems, such as lighting, home access control, entertainment systems and household appliances. This product can be included and operated in any Z-Waveânetwork with other Z-Wave certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.

Installation

Battery Installation

When the device report the low battery message. The user should replace the battery to new one. The battery type is CR123A, 3.0V. The way to open the front cover please press the top position, to release the cover.



Replace the new battery and install the cover back.
  1. Put the front cover bottom, and press down.
  2. Push the front cover top. 


Installation
  1. To mount the device on the wall, you can choose using the tape, or the screw.

 

Reset to factory default 1. Pressing tamper key four times within 1.5 seconds and do not release the tamper key in the 4 th pressed, and the LED will light ON.
2. After 3 seconds the LED will turn OFF, after that within 2 seconds, release the tamper key. If successful, the LED will light ON one second. Otherwise, the LED will flash once.
3. IDs are excluded and all settings will reset to factory default.
Inclusion Pressing the tamper key three times within 1.5 seconds to enter the inclusion mode.
Exclusion Pressing tamper key three times within 1.5 seconds to enter the exclusion mode. Node ID has been excluded.
NIF XXXNIF
Wakeup When the device power on, the device will wake about 20 seconds. In this duration, the controller can communicate with the device. Normally the device is always sleeping to save the battery energy.
Protection XXXProtection
FirmwareUpdate The device support the Z-Wave firmware update via OTA. Let the controller into the firmware update mode, and then press the tamper key once to start the update. After finish the firmware download, the LED will start flash in every 0.5 second. At that time, please don‘t remove the battery , otherwise it will cause the firmware broken, and the device will no function. After the LED stop flash, it is recommended that the user power up the device. Caution: After remove the battery, please wait about 30 seconds, and then re-install the battery.
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 8 Z-Wave Plus Lifeline

Configuration Parameters

Parameter 5: Operation Mode

Operation mode. Using bit to control.Bit0: Disable the Flood function.Bit1: Reserve.Bit2: Reserve.Bit3: Setting the temperature scale. 0: Fahrenheit, 1:CelsiusBit4: Reserve.Bit5: Disable the temperature report after event triggered. (1:Disable, 0:Enable)Bit6: Reserve.Bit7: Reserve.
Size: 1 Byte, Default Value: 0

Setting Description
1 Disable the Flood function.
8 Setting the temperature scale. 0: Fahrenheit, 1:Celsius
32 Disable the temperature report after event triggered. (1:Disable, 0:Enable)

Parameter 7: Customer Function


Size: 1 Byte, Default Value: 0

Setting Description
8 Disable send out BASIC OFF after the flood event cleared. (1:Disable, 0:Enable)
16 Notification Type, 0: Using Notification Report. 1: Using Sensor Binary Report.
32 Disable Multi CC in auto report. (1:Disable, 0:Enable)
64 Disable to report battery state when the device triggered. (1:Disable, 0:Enable)

Parameter 10: Auto Report Battery Time

The interval time for auto report the battery level. 0 means turn off auto report.The default value is 12. The tick time can setting by the configuration No.20.
Size: 1 Byte, Default Value: 18

Setting Description
0 - 127 The interval time for auto report the battery level.

Parameter 13: Auto Report Temperature Time

The interval time for auto report the temperature. 0 means turn off auto report.The default value is 12. The tick time can setting by the configuration No.20.
Size: 1 Byte, Default Value: 18

Setting Description
0 - 127 The interval time for auto report the temperature.

Parameter 14: Auto Report Humidity Time

The interval time for auto report the humidity. 0 means turn off auto report.The default value is 12. The tick time can setting by the configuration No.20.
Size: 1 Byte, Default Value: 18

Setting Description
0 - 127 The interval time for auto report the humidity.

Parameter 20: Auto Report Tick Interval

The interval time for auto report each tick. Setting this configuration will effect configuration No.10, No.13, No.14 and No.15.Units of one minute.Caution1: Setting to 0 means turn off all auto report function.Caution2: The value is unsigned byte
Size: 1 Byte, Default Value: 30

Setting Description
0 - 255 The interval time for auto report each tick.

Parameter 21: Temperature Differential Report

The temperature differential to report.0 means turn off this function. The unit is Fahrenheit.Enable this function the device will detect every 10 seconds. And when the temperature is over 140 degree Fahrenheit, it will continue report.
Size: 1 Byte, Default Value: 1

Setting Description
0 - 127 The temperature differential to report. 0 means turn off this function.

Parameter 23: Humidity Differential Report

The humidity differential to report.0 means turn off this function. The unit is percentage.Enable this function the device will detect every 10 seconds.
Size: 1 Byte, Default Value: 5

Setting Description
0 - 60 The humidity differential to report.

Technical Data

Dimensions 28x86x23 mm
Weight 20 gr
Hardware Platform SD3502
EAN 4250059696631
IP Class IP 20
Battery Type 1 * CR123A
Device Type Multilevel Sensor
Network Operation Reporting Sleeping Slave
Z-Wave Version 6.51.06
Certification ID ZC10-17035463
Z-Wave Product Id 0x0175.0x0002.0x0020
Sensors Air TemperatureHumidity
Color White
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW
EuropeMultilevel Sensor