Quickstart

This is a Routing Multilevel Sensor for XXXQFrequencyName. To run this device please insert fresh 2 * AA 1,5V batteries. To run this device please make sure the internal battery is fully charged. To add this device to your network execute the following action:

Press the LED button on the Z-Wave RS.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

Z-Wave RS is a battery operated temperature sensor. When included into Z-Wave wireless network, its buttons can also be used to control the heating system.

Installation

Product Usage

Reset to factory default
Inclusion
Press the LED button on the Z-Wave RS.
Exclusion Hold down the 3 buttons on the Z-Wave RS for 5 seconds (up, down and LED buttons).
NIF Each time the LED button is pressed the Z-Wave RS will and send NIF. This is also true when the Z-Wave RS is in tamper-proof mode.
Wakeup A controller can only communicate with the Z-Wave RS when it is awake. The intervals when the Z-Wave RS is awake can be set using the WakeUp Command Class. By default the WakeUp interval is 60 minutes. The Z-Wave RS can be woken manually by pushing any of the three buttons, and will stay awake for 10 seconds.
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 1 Lifeline

Configuration Parameters

Parameter 1: Temperature Report threshold


Size: 2 Byte, Default Value: 5

Setting Description
1 - 100 0.1 to 10°C

Parameter 2: Set-point display resolution


Size: 2 Byte, Default Value: 5

Setting Description
1 - 100 From 0.1 to 10°C in 0.1°C steps

Parameter 3: Min set-point and override limit


Size: 2 Byte, Default Value: 12

Setting Description
0 - 40 From min 0°C to max setpoint/override limit

Parameter 4: Max set-point and override limit


Size: 2 Byte, Default Value: 28

Setting Description
0 - 40 From min setpoint/override limit to max 40°C

Parameter 5: LED Flash period


Size: 2 Byte, Default Value: 1

Setting Description
0 - 65535 seconds

Parameter 6: Setpoint control function


Size: 1 Byte, Default Value: 1

Setting Description
0 Disabled
1 Enabled

Parameter 7: Temporarily override scheduler


Size: 1 Byte, Default Value: 1

Setting Description
0 Disabled
1 Enabled

Parameter 8: Setpoint Type in Thermostat_ Setpoint_Reports


Size: 1 Byte, Default Value: 1

Setting Description
1 Heating
2 Cooling
10 Auto Changeover

Parameter 9: LED on time


Size: 1 Byte, Default Value: 1

Setting Description
1 - 5 100 to 500ms in 100ms steps

Parameter 10: Number of LED flashes (duration)


Size: 1 Byte, Default Value: 5

Setting Description
0 - 255 flashes

Parameter 11: LED Color


Size: 1 Byte, Default Value: 1

Setting Description
1 Green
2 Red

Technical Data

Dimensions 75x75x18 mm
Weight 71 gr
Hardware Platform ZM3102
EAN 4250059693616
IP Class IP 21
Battery Type 2 * AA 1,5V
Device Type Central Controller
Generic Device Class Multilevel Sensor
Specific Device Class Routing Multilevel Sensor
Z-Wave Version 4.55.00
Certification ID ZC08-14070002
Z-Wave Product Id 0x0002.0x0003.0x8010
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW
EuropeCentral Controller