This is a
After the first action you can further manage and configure the wall controller using the management mode. To activate this management mode push all four buttons for one second simultaneously (green blinks slowly). The buttons will have different functions then (see Installation Guidelines).
Attention:For convenience reasons some special short cut apply IF and only IF the KFOB is the primary controller of the network: The first device included into a button group will define the commands sent out by this group regardless of the default value of the configuration parameters 11-14. If the device is a door lock the button group will turn into door lock control (value=7). For dimmers and motor controls the value changes into Multilevel Switch Control (value=1). All other devices will turn the button group into Basic control (value=2). All configuration values can be changed if needed. When KFOB is primary controller the very first device included will be automatically put into button group A and the command set will change according to the rules just mentioned. All other devices need ot be put in button groups manually.
The MT2652 Scene Switch is a Z-Wave device that can both control other Z-Wave devices and activate scenes. Although it is controlling other devices, the Wall Controller cannot act as Z-Wave network controller (primary or secondary) and will always need a Z-Wave network controller to be included into a Z-Wave network. The device can be used in different modes that are selected by configuration parameters:
Control of groups of other Z-Wave devices using ‘ON‘, ‘OFF‘ and Dim commands.
Activation of predefined scenes in Gateways or other Z-Wave devices.
This device support secure communication when included by a controller that also supports secure communication.
The device can be mounted on every flat surface either using the screws provided or the double sided tape provided as well.
To atviate the device and access hte four buttons independently for management mode operations please remove the rocker using a screw driver or simply the fingers. Push hard on one corner and lift the other corner so that the rocker will unsnap.
Depending on the button mode and operating modes configured using the configuration parameters the key fob can be used in different ways.
4 Groups are controlled with single button (parameter 1/2 = 0) The four buttons 1-4 control one single control group each: 1->A, 2->B, 3->C, 4->D. Single click turns devices in the control group on, double click turns them off. Click and hold can be used for dimming.
2 Groups are controlled with two buttons (parameter 1/2 = 1) The buttons 1 and 3 control the control group A (button one turns on, button three turns off), the buttons 2 and 4 control the control group B (button two turns on, button four turns off). In case dimmers are controlled, holding down the larger button will dim up, holding down the smaller button will dim down the load. Releasing the button will stop the dimming function.
4 Groups are controlled with two buttons and double click (parameter 1/2 = 2) This mode enhances the previous mode and allows to control two further control groups C and D using double clicks.
Example: Clicking/double clicking the button will issue scene triggers, scene 11 (button 1 click, event on), scene 12 (button double click 1, event off, single button control is used in this example)
Reset to factory default | Use this procedure only if the primary controller is missing or otherwise inoperable. (1) Turn the device into Management Mode by keeping all four buttons pushed for 5 seconds, (2) click on Button 3, (3) keep button 4 pushed for 4 seconds. |
Inclusion | Place your primary controller in inclusion mode by following the manufacturer‘s instructions, then activate inclusion on the wall controller by pressing any one of the four buttons for one second. Inclusion mode is indicated by the red/green blinking of the LEDs until the timeout occurs after 10 seconds. |
Exclusion | Re-Inclusion and Exclusion are performed by pushing button 1 in management mode. Pushing all four buttons for 5 sec. turns the device into management mode (indicated by blinking green LED). |
NIF | Pressing Button 2 in management mode will issue a Node Information Frame. |
Wakeup | (1) Turn the device into Management Mode by keeping all four buttons pushed for 5 seconds, (2) click on Button 2. |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 10 | Z-Wave Plus Lifeline |
2 | 10 | Control Group A, controlled by button 1 or single clicks of buttons 1 and 3 |
3 | 10 | Control Group B, controlled by button 2 or single clicks of buttons 2 and 4 |
4 | 10 | Control Group C, controlled by button 3 or double clicks of buttons 1 and 3 |
5 | 10 | Control Group D, controlled by button 4 or double clicks of buttons 2 and 4 |
In separate mode button 1 works with Group A, button 3 with Group C. Click is ON, Hold is dimming UP, Double click is OFF, Click-Hold is dimming DOWN. In pair button 1/3 are UP/DOWN correspondingly. Click is ON/OFF, Hold is dimming UP/DOWN. Single clicks works with Group A, double click with Group C. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Separately |
1 | In pair without double clicks |
2 | In pair with double clicks |
In separate mode button 2 works with control group B, button 4 with control group D. Click is ON, Hold is dimming UP, Double click is OFF, Click-Hold is dimming DOWN. In pair button B/D are UP/DOWN correspondingly. Click is ON/OFF, Hold is dimming UP/DOWN. Single clicks works with Group B, double click with Group D. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Separately |
1 | In pair without double clicks |
2 | In pair with double clicks |
This parameter defines the command to be sent to devices of control group A when the related button is pressed. Size: 1 Byte, Default Value: 8
Setting | Description |
---|---|
0 | Disable |
1 | Switch on/off and Dim (send Basic Set and Switch Multilevel) |
2 | Switch on/off only (send Basic Set) |
3 | Switch all |
4 | Send scenes |
5 | Send preconfigured scenes |
6 | Control devices in proximity |
7 | Control door lock |
8 | Central scene to gateway (default) |
This parameter defines the command to be sent to devices of control group B when the related button is pressed. Size: 1 Byte, Default Value: 8
Setting | Description |
---|---|
0 | Disable |
1 | Switch on/off and Dim (send Basic Set and Switch Multilevel) |
2 | Switch on/off only (send Basic Set) |
3 | Switch all |
4 | Send scenes |
5 | Send preconfigured scenes |
6 | Control devices in proximity |
7 | Control door lock |
8 | Central scene to gateway (default) |
This parameter defines the command to be sent to devices of control group C when the related button is pressed. Size: 1 Byte, Default Value: 8
Setting | Description |
---|---|
0 | Disable |
1 | Switch on/off and Dim (send Basic Set and Switch Multilevel) |
2 | Switch on/off only (send Basic Set) |
3 | Switch all |
4 | Send scenes |
5 | Send preconfigured scenes |
6 | Send preconfigured scenes |
7 | Control door lock |
8 | Central scene to gateway |
This parameter defines the command to be sent to devices of control group D when the related button is pressed. Size: 1 Byte, Default Value: 8
Setting | Description |
---|---|
0 | Disable |
1 | Switch on/off and Dim (send Basic Set and Switch Multilevel) |
2 | Switch on/off only (send Basic Set) |
3 | Switch all |
4 | Send scenes |
5 | Send preconfigured scenes |
6 | Control devices in proximity |
7 | Control door lock |
8 | Central scene to gateway (default) |
Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
1 | Switch off only |
2 | Switch on only |
255 | Switch all on and off |
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | No |
1 | Yes |
If the KFOB wakes up and there is no controller nearby, several unsuccessful communication attempts will drain battery. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Wake up is blocked |
1 | Wake up is possible if configured accordingly |
Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | No |
1 | To same node as Wake Up Notification |
2 | Broadcast to neighbors |
Dimensions | 0.0830000x0.0830000x0.0140000 mm |
Weight | 40 gr |
Hardware Platform | ZM5202 |
EAN | 4250059693593 |
IP Class | IP 20 |
Battery Type | 1 * CR2032 |
Device Type | Wall Controller |
Network Operation | Portable Slave |
Z-Wave Version | 6.51.01 |
Certification ID | ZC10-14090021 |
Z-Wave Product Id | 0x0175.0x0100.0x0101 |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |