Quickstart

This is a secure Wall Controller for XXXQFrequencyName. To run this device please insert fresh 1 * CR2032 batteries. To run this device please make sure the internal battery is fully charged. This wireless Z–Wave wall controller can act in two different modes that are activated with the first configuration action after factory default: 

  1. Pushing Button 1 for one sec. (red/green blink) adds the wireless wall controller to an existing network as secondary controller. The four buttons will send activate 4 different scenes (Central Scene Command) in the central controller The wall controller is able to control up to 4 different scenes with its four buttons. (with different configuration even more)
  2. Pushing Button 3 for one sec. (green blink) adds a new Z-Wave actuator device to the controller who becomes the primary controller of this new network. The connected new device (actuator) can be controlled using the two buttons left (Button 1 = up/on/open, Button 3 = down/off/closed).
After the first action you can further manage and configure the wall controller using the management mode. To activate this management mode push all four buttons for one second simultaneously (green blinks slowly). The buttons will have different functions then (see Installation Guidelines).


Attention:For convenience reasons some special short cut apply IF and only IF the KFOB is the primary controller of the network: The first device included into a button group will define the commands sent out by this group regardless of the default value of the configuration parameters 11-14. If the device is a door lock the button group will turn into door lock control (value=7). For dimmers and motor controls the value changes into Multilevel Switch Control (value=1). All other devices will turn the button group into Basic control (value=2). All configuration values can be changed if needed. When KFOB is primary controller the very first device included will be automatically put into button group A and the command set will change according to the rules just mentioned. All other devices need ot be put in button groups manually.


Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

The MT2652 Scene Switch is a Z-Wave device that can both control other Z-Wave devices and activate scenes. Although it is controlling other devices, the Wall Controller cannot act as Z-Wave network controller (primary or secondary) and will always need a Z-Wave network controller to be included into a Z-Wave network. The device can be used in different modes that are selected by configuration parameters:

Control of groups of other Z-Wave devices using ‘ON‘, ‘OFF‘ and Dim commands.
Activation of predefined scenes in Gateways or other Z-Wave devices.
This device support secure communication when included by a controller that also supports secure communication.

Installation

The device can be mounted on every flat surface either using the screws provided or the double sided tape provided as well.
To atviate the device and access hte four buttons independently for management mode operations please remove the rocker using a screw driver or simply the fingers. Push hard on one corner and lift the other corner so that the rocker will unsnap.

The device can be mounted on every dry and flat surface using either screws or double side adhesive. First the mounting base is fixed on the wall. Next step the switch frame is placed on the 2 frame and the electronic insert is used to fix the frame to the mounting base as shown on the image. Finally the switching paddle(s) are mounted on the electronic base.
For battery change, the switching paddle(s) need to be removed. The CR battery can be replaced by pushing the little nipple above the battery. The old battery will slide out and the new battery is inserted until the nipple will hold it again.
The device can be operated in two different modes: 
  • Operation Mode: This is the mode where the device is controlling other Z-Wave devices or is activating scenes.
  • Management Mode: The device is turned into the management mode by pushing all four buttons for one second together. A blinking green LED indicates the management mode. In the management mode the buttons of the device have different functions. If no further action is performed, the device will turn back to the normal mode after 10 sec. Any management action terminates the management mode as well.
In management mode the following actions can be performed:
 
  • Button 1 - Inclusion/Exclusion: Every inclusion or exclusion attempt is confirmed by hitting this button. Single Click is used for standard inclusion and exclusion, double click is used for network wide inclusion. With this operation the device can be included into a Z-Wave Network from any physical location in the network. This requires a primary controller supporting network wide inclusion. This mode lasts for 20 seconds and stops automatically. Any button press stops the mode as well.
  • Button 2 - Sends Node Information Frame and Wake up Notification. (see explanation below)
  • Button 3 - Activates the primary controller management menu. The following sub menu items are available:
  • Button 3 followed by short click of button 1: Start Secure Inclusion
  • Button 3 followed by short click of button 2: Start Unsecure Inclusion
  • Button 3 followed by short click of button 3: Start Exclusion
  • Button 3 followed by short click of button 4: Start Primary Handover
  • Button 3 followed by pushing button 4 for 5 seconds: Factory Default Reset. After clicking on button 3 keep button 4 pushed for 4 seconds
  • Button 4 - Enters into Association mode to assign target devices to one of the four associations. Refer to the manuals section about association for more information how to set and unset association groups.
In factory default mode pushing one of the four buttons for 1 sec will start different inclusion modes:
 
  • Button 1: Include as secondary controller
  • Button 2: Include as secondary controller - non secure
  • Button 3: Include new device into wall controllers network
  • Button 4: Include new device into wall controllers network - non secure
The process for button 1 and 2 is indicated with fast red/green blinking, the process for button 3 and 4 shows a fast green blinking. Every button push stops the process. This fast inclusion only works when device is in factory default.
 
Attention: For convenience reasons some special short cut apply IF and only IF the wall controller is the primary controller of the network: The first device included into a button group will define the commands sent out by this group regardless of the default value of the configuration parameters 11-14. If the device is a door lock the button group will turn into door lock control (value=7). For dimmers and motor controls the value changes into Multilevel Switch Control (value=1). All other devices will turn the button group into Basic control (value=2). All configuration values can be changed if needed. When wall controller is primary controller the very first device included will be automatically put into button group A and the command set will change according to the rules just mentioned. All other devices need ot be put in button groups manually.
 

Product Usage

Depending on the button mode and operating modes configured using the configuration parameters the key fob can be used in different ways.

Button modes:

4 Groups are controlled with single button (parameter 1/2 = 0) The four buttons 1-4 control one single control group each: 1->A, 2->B, 3->C, 4->D. Single click turns devices in the control group on, double click turns them off. Click and hold can be used for dimming.

2 Groups are controlled with two buttons (parameter 1/2 = 1) The buttons 1 and 3 control the control group A (button one turns on, button three turns off), the buttons 2 and 4 control the control group B (button two turns on, button four turns off). In case dimmers are controlled, holding down the larger button will dim up, holding down the smaller button will dim down the load. Releasing the button will stop the dimming function.

4 Groups are controlled with two buttons and double click (parameter 1/2 = 2) This mode enhances the previous mode and allows to control two further control groups C and D using double clicks.

Operating modes:

The devices supports 8 different operating modes - this means the kind of command sent out when pushing a button. Operating modes either directly control other devices or they issue various scene activation commands to a central controller. Operating modes for direct device control are:
  • Direct Control of associated devices with On/Off/Dim commands (parameter 11...14 = 1). Devices are controlled using Basic Set On/Off commands and Switch-Multilevel Dim Start/Stop. This mode implements communication pattern 7.
  • Direct Control of associated devices with only On/Off commands (parameter 11...14 = 2). Devices are controlled using only Basic Set On/Off commands. On dimming Up event On is sent, on dimming Down Off is sent. This mode also implements communication pattern 7.
  • Switch All commands (parameter 11...14 = 3) In this mode a all neighboring devices will receive Switch-All Set On/Off command and interpret it according to their membership in Switch-All groups. This mode implements communication pattern 7.
  • Direct Control of Devices in proximity (parameter 11...14 = 6). Basic Set and Switch-Multilevel Dim commands are sent to a device in proximity (50...100 cm) from the Fob. Attention: In case there are more than one Z-Wave devices nearby all these devices may be switched. For this reason the proximity function should be handled with care. This mode implements communication pattern 7
  • Door Lock Control (parameter 11...14 = 7) This mode allows direct control (open/close) of electronic door locks using secure communication. The mode implements communication pattern 7.
Operating modes for scene activation are:
  • Direct Activation of preconfigured scenes (parameter 11...14 = 5) Associated devices in an association group are controlled by individual commands defines by Z-Wave command class ?Scene Controller Configuration?. This mode enhances mode Direct Control of associated devices with On/Off/Dim commands and implements communication patterns 6 and 7. Please turn the button mode to "separate" to allow different a scene ID on every button.
  • Scene Activation in IP Gateway (parameter 11...14 = 4) If configured correctly the buttons can trigger a scene in a gateway. The scene number triggered is a combination of the group number and the action performed on the button and has always two digits. The group number defines the upper digit of the scene number, the action the lower digit. The following actions are possible:
    • 1 = On
    • 2 = Off
    • 3 = Dim Up Start
    • 4 = Dim Down Start
    • 5 = Dim Up Stop
    • 6 = Dim Down Stop

    Example: Clicking/double clicking the button will issue scene triggers, scene 11 (button 1 click, event on), scene 12 (button double click 1, event off, single button control is used in this example)

  • Activation of Central Scenes (parameter 11...14 = 8,Default) Z-Wave Plus introduces a new process for scene activation - the central scene control. Pushing a button and releasing a button send a certain command to the central controller using the lifeline association group. This allows reacting both on button push and button release. This mode implements communication patterns 6 but requires a central gateway supporting Z-Wave Plus.
LED Indication
  • Confirmation - green 1 sec
  • Failure - red 1 sec
  • Button press confirmation - green 1/4 sec
  • Waiting for Network Management mode selection - slow green blinks
  • Waiting for group selection in Association Set Mode - green fast blink
  • Waiting for primary controller function selection - green fast blink
  • Waiting for NIF in Association Set Mode - green-red-off blink

Reset to factory default Use this procedure only if the primary controller is missing or otherwise inoperable. (1) Turn the device into Management Mode by keeping all four buttons pushed for 5 seconds, (2) click on Button 3, (3) keep button 4 pushed for 4 seconds.
Inclusion Place your primary controller in inclusion mode by following the manufacturer‘s instructions, then activate inclusion on the wall controller by pressing any one of the four buttons for one second. Inclusion mode is indicated by the red/green blinking of the LEDs until the timeout occurs after 10 seconds.
Exclusion Re-Inclusion and Exclusion are performed by pushing button 1 in management mode. Pushing all four buttons for 5 sec. turns the device into management mode (indicated by blinking green LED).
NIF Pressing Button 2 in management mode will issue a Node Information Frame.
Wakeup (1) Turn the device into Management Mode by keeping all four buttons pushed for 5 seconds, (2) click on Button 2.
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 10 Z-Wave Plus Lifeline
2 10 Control Group A, controlled by button 1 or single clicks of buttons 1 and 3
3 10 Control Group B, controlled by button 2 or single clicks of buttons 2 and 4
4 10 Control Group C, controlled by button 3 or double clicks of buttons 1 and 3
5 10 Control Group D, controlled by button 4 or double clicks of buttons 2 and 4

Configuration Parameters

Parameter 1: Button 1 and 3 pair mode

In separate mode button 1 works with Group A, button 3 with Group C. Click is ON, Hold is dimming UP, Double click is OFF, Click-Hold is dimming DOWN. In pair button 1/3 are UP/DOWN correspondingly. Click is ON/OFF, Hold is dimming UP/DOWN. Single clicks works with Group A, double click with Group C.
Size: 1 Byte, Default Value: 1

Setting Description
0 Separately
1 In pair without double clicks
2 In pair with double clicks

Parameter 2: Button 2 and 4 pair mode

In separate mode button 2 works with control group B, button 4 with control group D. Click is ON, Hold is dimming UP, Double click is OFF, Click-Hold is dimming DOWN. In pair button B/D are UP/DOWN correspondingly. Click is ON/OFF, Hold is dimming UP/DOWN. Single clicks works with Group B, double click with Group D.
Size: 1 Byte, Default Value: 1

Setting Description
0 Separately
1 In pair without double clicks
2 In pair with double clicks

Parameter 11: Command to control Group A

This parameter defines the command to be sent to devices of control group A when the related button is pressed.
Size: 1 Byte, Default Value: 8

Setting Description
0 Disable
1 Switch on/off and Dim (send Basic Set and Switch Multilevel)
2 Switch on/off only (send Basic Set)
3 Switch all
4 Send scenes
5 Send preconfigured scenes
6 Control devices in proximity
7 Control door lock
8 Central scene to gateway (default)

Parameter 12: Command to control Group B

This parameter defines the command to be sent to devices of control group B when the related button is pressed.
Size: 1 Byte, Default Value: 8

Setting Description
0 Disable
1 Switch on/off and Dim (send Basic Set and Switch Multilevel)
2 Switch on/off only (send Basic Set)
3 Switch all
4 Send scenes
5 Send preconfigured scenes
6 Control devices in proximity
7 Control door lock
8 Central scene to gateway (default)

Parameter 13: Command to control Group C

This parameter defines the command to be sent to devices of control group C when the related button is pressed.
Size: 1 Byte, Default Value: 8

Setting Description
0 Disable
1 Switch on/off and Dim (send Basic Set and Switch Multilevel)
2 Switch on/off only (send Basic Set)
3 Switch all
4 Send scenes
5 Send preconfigured scenes
6 Send preconfigured scenes
7 Control door lock
8 Central scene to gateway

Parameter 14: Command to control Group D

This parameter defines the command to be sent to devices of control group D when the related button is pressed.
Size: 1 Byte, Default Value: 8

Setting Description
0 Disable
1 Switch on/off and Dim (send Basic Set and Switch Multilevel)
2 Switch on/off only (send Basic Set)
3 Switch all
4 Send scenes
5 Send preconfigured scenes
6 Control devices in proximity
7 Control door lock
8 Central scene to gateway (default)

Parameter 21: Send the following switch all commands


Size: 1 Byte, Default Value: 1

Setting Description
1 Switch off only
2 Switch on only
255 Switch all on and off

Parameter 22: Invert buttons


Size: 1 Byte, Default Value: 0

Setting Description
0 No
1 Yes

Parameter 25: Blocks wake up even when Wake Up Interval is set

If the KFOB wakes up and there is no controller nearby, several unsuccessful communication attempts will drain battery.
Size: 1 Byte, Default Value: 0

Setting Description
0 Wake up is blocked
1 Wake up is possible if configured accordingly

Parameter 30: Send unsolicited battery report on Wake Up


Size: 1 Byte, Default Value: 1

Setting Description
0 No
1 To same node as Wake Up Notification
2 Broadcast to neighbors

Technical Data

Dimensions 0.0830000x0.0830000x0.0140000 mm
Weight 40 gr
Hardware Platform ZM5202
EAN 4250059693593
IP Class IP 20
Battery Type 1 * CR2032
Device Type Wall Controller
Network Operation Portable Slave
Z-Wave Version 6.51.01
Certification ID ZC10-14090021
Z-Wave Product Id 0x0175.0x0100.0x0101
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW
EuropeWall Controller