Quickstart

This is a On/Off Power Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
1. Put the Z-Wave Controller into inclusion mode.2. Press the link key three times within 1.5 seconds to put the unit into inclusion mode. (Please refer to the documentation for the location of the link key.)



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

The Metering Plug is a Z-Wave enabled device which is fully compatible with any Z-Wave enabled network.Z-Wave enabled devices displaying the Z-Wave logo can also be used with it regardless of the manufacturer, and ours can also be used in other manufacturers Z-Wave enabled networks.Inclusion of this unit on other manufacturers Wireless Controller menu allows remote operation of the unit and the connected load.The Metering Plug is designed to control the on/off status of lighting and appliances load in your house.For metering the unit can detect up to 10485.75kW/h before resetting to 0 and can support wattage, voltage, ampere, and PF detection. The unit can also detect overload upon which the unit will switch off relay and keep LED flashing until power is off and re-applied.At 220-240V voltage, this Plug can support up to 2500W resistive, 1200W incandescent, 700W motor, or 320W (40W*8) fluorescent load.

Reset to factory default (This procedure should only be used when the network primary controller is inoperable.)1. Press the link key three times within 1.5 seconds to put the unit into exclusion mode.2. Within 1 second of step 1, press link key again and hold it until LED is off (about 5 seconds). (Please refer to the documentation for the location of the link key.)3. Node ID is excluded.The device reverts to factory default state and will be in auto-inclusion mode for 4 minutes..
Inclusion 1. Put the Z-Wave Controller into inclusion mode.2. Press the link key three times within 1.5 seconds to put the unit into inclusion mode. (Please refer to the documentation for the location of the link key.)
Exclusion 1. Put the Z-Wave Controller into exclusion mode.2. Press the link key three times within 1.5 seconds to put the unit into exclusion mode. (Please refer to the documentation for the location of the link key.)
NIF XXXNIF
Wakeup NR
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 1 1. When the unit is powered for the first time, the unit will send a Notification Report to the node of Group 1.2. When setting the unit or changing the units status, the unit will send a Binary Switch Report to the node of Group 1.3. When performing Reset the unit will send Device Reset Locally Notification to the node of Group1.4. The unit can be configured to periodically report the value of W and/or kW*h to the node of Group 1 (refer to Configuration parameter 4 & 5).The interval time between two reports is at least 30 seconds.5. The unit can be configured to report the status of wattage to the node of Group 1 on special occasions (refer to Configuration parameter 6 & 7).6. The minimum interval time between two reports sent from this unit to the node of Group 1 is 3 seconds.Refer to Configuration parameter 2 for more information.
2 4 When the button on the unit or the wall switch is pressed, the unit will send a Basic Set command to the nodes of Group 2.When the unit is OFF, Basic Set Value = 0x00.When the unit is ON, Basic Set Value = 0xFF.

Configuration Parameters

Parameter 1: Set Basic Set Command value

Set Basic Set Command value
Size: 2 Byte, Default Value: 255

Setting Description

Parameter 2: Set the delaying time to report to Group 1

Set the delaying time to report to Group 1
Size: 1 Byte, Default Value: 3

Setting Description

Parameter 3: Set whether to remember the last status

Set whether to remember the last status, 1: remember, 0: do not remember
Size: 1 Byte, Default Value: 1

Setting Description

Parameter 4: Set the interval for wattage auto report

Set the interval for wattage auto report
Size: 2 Byte, Default Value: 1

Setting Description

Parameter 5: Set the interval for kW*h auto report

Set the interval for kW*h auto report
Size: 2 Byte, Default Value: 60

Setting Description

Parameter 6: Auto report when load surpasses the set value of wattage

Auto report when load surpasses the set value of wattage
Size: 2 Byte, Default Value: 0

Setting Description

Parameter 7: Auto report when the change of wattage surpasses the set percentage

Auto report when the change of wattage surpasses the set percentage
Size: 1 Byte, Default Value: 0

Setting Description

Technical Data

Hardware Platform SD3502
Device Type On/Off Power Switch
Network Operation Always On Slave
Firmware Version 02
Z-Wave Version 6.51.02
Certification ID ZC10-14080015
Z-Wave Product Id 0x0060.0x0004.0x0006
Frequency XXfrequency
Maximum transmission power XXantenna
CEPT (Europe)On/Off Power Switch