1. Put the Z-Wave Controller into inclusion mode.2. Press the link key three times within 1.5 seconds to put the unit into inclusion mode. (Please refer to the documentation for the location of the link key.)
The Metering Plug is a Z-Wave enabled device which is fully compatible with any Z-Wave enabled network.Z-Wave enabled devices displaying the Z-Wave logo can also be used with it regardless of the manufacturer, and ours can also be used in other manufacturers Z-Wave enabled networks.Inclusion of this unit on other manufacturers Wireless Controller menu allows remote operation of the unit and the connected load.The Metering Plug is designed to control the on/off status of lighting and appliances load in your house.For metering the unit can detect up to 10485.75kW/h before resetting to 0 and can support wattage, voltage, ampere, and PF detection. The unit can also detect overload upon which the unit will switch off relay and keep LED flashing until power is off and re-applied.At 220-240V voltage, this Plug can support up to 2500W resistive, 1200W incandescent, 700W motor, or 320W (40W*8) fluorescent load.
Reset to factory default | (This procedure should only be used when the network primary controller is inoperable.)1. Press the link key three times within 1.5 seconds to put the unit into exclusion mode.2. Within 1 second of step 1, press link key again and hold it until LED is off (about 5 seconds). (Please refer to the documentation for the location of the link key.)3. Node ID is excluded.The device reverts to factory default state and will be in auto-inclusion mode for 4 minutes.. |
Inclusion | 1. Put the Z-Wave Controller into inclusion mode.2. Press the link key three times within 1.5 seconds to put the unit into inclusion mode. (Please refer to the documentation for the location of the link key.) |
Exclusion | 1. Put the Z-Wave Controller into exclusion mode.2. Press the link key three times within 1.5 seconds to put the unit into exclusion mode. (Please refer to the documentation for the location of the link key.) |
NIF | XXXNIF |
Wakeup | NR |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | 1. When the unit is powered for the first time, the unit will send a Notification Report to the node of Group 1.2. When setting the unit or changing the units status, the unit will send a Binary Switch Report to the node of Group 1.3. When performing Reset the unit will send Device Reset Locally Notification to the node of Group1.4. The unit can be configured to periodically report the value of W and/or kW*h to the node of Group 1 (refer to Configuration parameter 4 & 5).The interval time between two reports is at least 30 seconds.5. The unit can be configured to report the status of wattage to the node of Group 1 on special occasions (refer to Configuration parameter 6 & 7).6. The minimum interval time between two reports sent from this unit to the node of Group 1 is 3 seconds.Refer to Configuration parameter 2 for more information. |
2 | 4 | When the button on the unit or the wall switch is pressed, the unit will send a Basic Set command to the nodes of Group 2.When the unit is OFF, Basic Set Value = 0x00.When the unit is ON, Basic Set Value = 0xFF. |
Set Basic Set Command value Size: 2 Byte, Default Value: 255
Setting | Description |
---|
Set the delaying time to report to Group 1 Size: 1 Byte, Default Value: 3
Setting | Description |
---|
Set whether to remember the last status, 1: remember, 0: do not remember Size: 1 Byte, Default Value: 1
Setting | Description |
---|
Set the interval for wattage auto report Size: 2 Byte, Default Value: 1
Setting | Description |
---|
Set the interval for kW*h auto report Size: 2 Byte, Default Value: 60
Setting | Description |
---|
Auto report when load surpasses the set value of wattage Size: 2 Byte, Default Value: 0
Setting | Description |
---|
Auto report when the change of wattage surpasses the set percentage Size: 1 Byte, Default Value: 0
Setting | Description |
---|
Hardware Platform | SD3502 |
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Firmware Version | 02 |
Z-Wave Version | 6.51.02 |
Certification ID | ZC10-14080015 |
Z-Wave Product Id | 0x0060.0x0004.0x0006 |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |