This is a
1. With the gateway application scan the QR code on the Device label and add the Security 2 (S2) Device Specific Key (DSK) to the Provisioning List in the gateway.
2. Connect the Device to a power supply.
3. Check if the blue LED is blinking in Mode 1. If so, the Device is not added to a Z-Wave™ network.
4. Adding will be initiated automatically within a few seconds after connecting the Device to a power supply, and the Device will be added to a Z-Wave™ network automatically.
5. The blue LED will be blinking in Mode 2 during the adding process.
6. The load connected to O will be blinking 1s on/1s off/1s on/1s off if the Device is successfully added to a Z-Wave™ network.
7. The green LED will be blinking in Mode 1 if the Device is successfully added to a Z-Wave™ network.
With the Wave Shutter, remotely automate and control the position of shutters, blinds, windows, awnings, pool covers and other devices powered by bidirectional AC motors. Using Z-Wave, smart home products can seamlessly communicate with each other, regardless of their brand or interface, thanks to a centralized smart hub! Shelly Qubino devices work with the latest generation Z-Wave chip (S800), one of the world"s most popular standardized technologies for smart homes. Wave Shutter is retrofittable and designed to fit behind any switch or outlet, instantly turning it into a smart outlet. Once installed, you can plug it into your Z-Wave network (Z-Wave gateway required) and control connected devices from anywhere using your smartphone or tablet. Shelly Qubino devices work with over 4000 Z-Wave certified devices and gateways.
The Device can control a bi-directional AC motor. It can be retrofitted into standard electrical wall boxes, behind the switches or other places with limited space.
⚠CAUTION! Danger of electrocution. Mounting/installation of the Device to the power grid has to be performed with caution, by a qualified electrician.
⚠CAUTION! Danger of electrocution. Every change in the connections has to be done after ensuring there is no voltage present at the Device terminals.
⚠CAUTION! Use the Device only with a power grid and appliances that comply with all applicable regulations. A short circuit in the power grid or any appliance connected to the Device may damage it.
⚠CAUTION! Do not connect the Device to appliances exceeding the given max. load!
⚠CAUTION! Do not shorten the antenna.
⚠RECOMMENDATION: Place the antenna as far away as possible from metal elements as they can cause signal interference.
⚠CAUTION! Connect the Device only in the way shown in these instructions. Any other method could cause damage and/or injury.
⚠CAUTION! Do not install the Device where it can get wet.
⚠CAUTION! Do not use the Device if it has been damaged!
⚠CAUTION! Do not attempt to service or repair the Device yourself!
⚠RECOMMENDATION: Connect the Device using solid single-core wires with increased insulation heat resistance not less than PVC T105°C (221°F).
⚠CAUTION! Before starting the mounting/installation of the Device, check that the breakers are turned off and there is no voltage on their terminals. This can be done with a phase tester or multimeter. When you are sure that there is no voltage, you can proceed to connecting the wires.
⚠CAUTION! Use only one phase AC circuit. Do not use mixed AC and DC circuits.
Connect both L terminals to the Live wire and the N terminal to the Neutral wire. Connect the common motor terminal/wire to the Neutral wire. Connect motor direction terminals/wires to the O1 and O2 terminals.* Connect the first switch/push-button to the SW1
terminal and the Live wire. Connect the second switch/push-button to the SW2 terminal and the Live wire. *The Device outputs can be reconfigured to match the required rotation direction.
Legend
Device terminals:
• N: Neutral terminal
• L: Live terminals (110–240 V AC)
• O1: Output terminal for motor UP (open)
• O2: Output terminal for motor DOWN (close)
• SW1: Input terminal for switch/push-button UP (open)
• SW2: Input terminal for switch/push-button DOWN (close)
⚠RECOMMENDATION: For inductive appliances that cause voltage spikes during switching on/off, such as electrical motors, fans, vacuum cleaners and similar ones, RC snubber (0.1 μF / 100 Ω / 1/2 W / 600 V AC) should be connected parallel to the appliance.
⚠CAUTION! Do not allow children to play with the push-buttons/switches connected to the Device. Keep the devices for remote control of Shelly Qubino (mobile phones, tablets, PCs) away from children.
Calibration
Automatic calibration is a process during which the Device learns the position of the limit switches.
Note! For the correct position operation, the Device must perform a calibration procedure!
Note! The motor must be equipped with electronic or mechanical limit switches and the limit positions must be set correctly before calibration!
Note! The calibration is successful when the Device performs a complete cycle of movement: up, down, up, down to 50%.
Note! If the calibration is not executed, check that the limit switches are correctly set and that the wiring is done according to the instructions in the User Guide.
Automatic calibration with the push-button SW1:
Note! Calibration with the push-button SW1 is not time-limited and can be started anytime.
1. Move blind to the top (upper) position.
2. Press SW1 4 times in 3 seconds.
3. The Device will start calibration and complete 3 cycles: down, up, down to 50%.
4. Check the LED status to see if the calibration has been successful.
Automatic calibration with the S button:
Note! Calibration with the S button is not time-limited and can be started anytime.
1. Enter the setting mode by pressing the S button for less than0,5s (short press).
2. Keep pressing the S button until the calibration is selected, indicated by the yellow LED colour.
3. Start calibration by pressing the S button for more than 2 seconds.
4. The Device will start calibration and complete 3 cycles: down, up, down to 50%.
5. Check the LED status to see if the calibration has been successful.
Venetian Mode
Slats tilting position calibration (Venetian mode)
Parameter No. 71 set to 1. When enabling the “venetian blind” mode, position calibration for slats titling must be done. After that, the position and angle of the slats can be set. By default, the rotation time of slats is set to 1,5 s. This value can be changed with the Parameter No. 72.
1. Add (include) and perform the Device calibration process according to the ‘Shutter positioning calibration’ section.
2. Set the Parameter No. 71 to 1 “Venetian blinds”.
3. By default, the full rotation time is set to 1,5 s. If this time is too long (if the blind starts to move up or down after the slats full cycle), decrease this time with the Parameter No. 72. If this time is too short (if the slats do not turn for a full cycle), increase this time with the Parameter No. 72.
4. Repeat the 3rd step until the position of the slats is correct.
Operational Instructions
If the inputs are configured as push-buttons:
• Pressing the push-button when the blind is static, moves the blind in the corresponding direction until the endpoint is reached.
• Pressing the push-button for the same direction while the blind is moving, stops the blind.
• Pressing the push-button for the opposite direction while the blind is moving, reverses the blind movement until the endpoint is reached.
If the inputs are configured as switches:
• Turning the switch on moves the blind in the corresponding direction until the endpoint is reached.
• Turning the switch off stops the blind movement.
• If both switches are turned on, the Device respects the last engaged switch. Turning off the last engaged switch stops the blind movement, even if the other switch is still on.
• To move the blind in the opposite direction, the other switch has to be turned off and on again.
LED Signalization
Reset to factory default | 1. To enter the Setting mode, quickly press and hold the S button on the Device until the LED turns Solid blue. 2. Press the S button multiple times until the LED turns Solid red. 3. Press and hold (> 2s) S button on the Device until the red LED starts blinking in Mode 3. Releasing the S button will start the factory reset. 4. During factory reset, the LED will turn solid green for about 1s, then the blue and red LED will start blinking in Mode 3 for approx. 2s. 5. The blue LED will be blinking in Mode 1 if the Factory reset is successful. |
Inclusion | 1. Connect the Device to a power supply. 2. Check if the blue LED is blinking in Mode 1. If so, the Device is not added to a Z-Wave™ network. 3. Enable add/remove mode on the gateway. 4. To enter the setting mode, quickly press and hold the S button on the Device until the LED turns Solid blue. 5. Quickly release and then press and hold (> 2 s) the S button on the Device until the blue LED starts blinking in Mode 3. Releasing the S button will start the LEARN MODE. 6. The blue LED will be blinking in Mode 2 during the adding process. 7. The load connected to O will be blinking 1s on/1s off/1s on/1s off if the Device is successfully added to a Z-Wave™ network. 8. The green LED will be blinking in Mode 1 if the Device is successfully added to a Z-Wave™ network. |
Exclusion | 1. Connect the Device to a power supply. 2. Check if the green LED is blinking in Mode 1. If so, the Device is added to a Z-Wave™ network. 3. Enable add/remove mode on the gateway. 4. To enter the Setting mode, quickly press and hold the S button on the Device until the LED turns Solid blue. 5. Quickly release and then press and hold (> 2s) the S button on the Device until the blue LED starts blinking in Mode 3. Releasing the S button will start the LEARN MODE. 6. The blue LED will be blinking in Mode 2 during the removing process. 7. The load connected to O will be blinking 1s on/1s off/1s on/1s off if the Device is successfully removed from a Z-Wave™ network. 8. The blue LED will be blinking in Mode 1 if the Device is successfully removed from a Z-Wave™ network. |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 9 | Lifeline |
2 | 9 | SW1 Shuttermode SWITCH_MULTILEVEL |
3 | 9 | SW1 Venitian Mode SWITCH_MULTILEVEL |
4 | 9 | BASIC_SET : set On / Off state at the associated device |
5 | 9 | BASIC_SET : set On / Off state at the associated device |
6 | 9 | SW2 Shuttermode SWITCH_MULTILEVEL |
7 | 9 | SW2 Venitian Mode SWITCH_MULTILEVEL |
This parameter defines how the Device should treat the switch (which type) connected to the SW (SW1) terminal. Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | momentary switch (push button) |
1 | toggle switch (contact closed - ON / contact opened - OFF) |
2 | toggle switch (Device changes status when switch changes status) |
This parameter allows to reverse the operation of switches connected to SW1 and SW2 inputs without changing the wiring. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | default (SW1 - O1, I2 - O2) |
1 | reversed (SW1 - O2, I2 - O1) |
This parameter allows to reverse the operation of switches connected to SW1 and SW2 inputs without changing the wiring. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | default (O1 - UP, O2 - DOWN) |
1 | reversed (O1 - DOWN, O2 - UP) |
Choose by how much the power (W) consumption needs to increase or decrease to be reported. Values correspond to percentages, so if 50 is set (by default), the Device will report any power consumption changes of 50 % or more, compared to the last reading. Size: 1 Byte, Default Value: 50
Setting | Description |
---|---|
0 | Power consumption reporting disabled |
1 - 100 | % Power consumption reporting enabled. |
Choose between the two operating modes. In shutter mode, you can select up/down/stop. In venetian mode, an additional widget/endpoint is displayed in the UI interface, which you can use to control the tilt position of the slats. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Shutter mode |
1 | Venetian mode with (up/down and slats rotation) |
2 | Manual time set (No end switches) |
Set the time required for the slats to make a full turn (180 degrees). Size: 2 Byte, Default Value: 150
Setting | Description |
---|---|
0 | turning time disabled |
1 - 32767 | 0.01 seconds – 327.67 seconds |
This parameter is used to enable/disable the slats to return to the previously set position, after being activated via the gateway, push-button operation or when the lower limit switch is reached. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | disable |
1 | enable |
Define the power consumption threshold at the end positions. Based on this value, the Device will know that the shutters reached the limit switches. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Disabled: reaching a limit switch will not be detected |
1 | Auto power calibration |
2 - 255 | (2-255W) - report interval |
By setting this parameter to value 1 the Device will start executing force calibration procedure. The parameter also reports the calibration status by sending the get parameter value command. Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
1 | start calibration |
2 | device is calibrated (read only) |
3 | device is not calibrated (read only) |
4 | calibration error (read only) |
This parameter defines the delay time for the motor to turn off, after reaching the limit switch. Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
0 - 255 | (0-25.5s) - time |
Define the maximum time before the power consumption of the motor is read from the Device, after one of the relays is switched on. If there is no power consumption during the set time (motor is not connected, damaged or requires longer time to start, motor is at the end position), the relay will switch off. This time is defined by entering it manually. Size: 1 Byte, Default Value: 30
Setting | Description |
---|---|
0 | time is set automatically |
3 - 50 | 0.3seconds – 5seconds (100ms resolution) |
When the shutter is not calibrated (or the motor is not equipped with a limit switch), this parameter defines the movement time of the motor. Size: 2 Byte, Default Value: 120
Setting | Description |
---|---|
1 - 32000 | seconds |
65000 | unlimited time |
Dimensions | 42 x 37 x 16 mm |
Weight | 29 gr |
Hardware Platform | EFR32ZG23 |
EAN | 3800235269008 |
IP Class | IP 20 |
Voltage | 230V |
Load | 2 x 10A |
Device Type | Window Covering Endpoint Aware |
Generic Device Class | Multilevel Switch |
Specific Device Class | Motor Control Device (B) |
Firmware Version | 12.13 |
Z-Wave Version | 07.13 |
Z-Wave Product Id | 0x0460.0x0003.0x0082 |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |