Quickstart
This is a
secure
Meter for XXXQFrequencyName.
To run this device please connect it to your mains power supply.
- With the gateway application scan the QR code on the Device label and add the Security 2 (S2) Device Specific Key (DSK) to the provisioning list in the gateway.
- Connect the Device to a power supply.
- Check if the blue LED is blinking in Mode 1. If so, the Device is not added to a Z-Wave® network.
- Adding will be initiated automatically within a few seconds after connecting the Device to a power supply, and the Device will be added to a Z-Wave® network automatically.
- The blue LED will be blinking in Mode 2 during the adding process.
- The green LED will be blinking in Mode 1 if the Device is successfully added to a Z-Wave® network.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Product Description
The Device is a small form factor smart power meter, which allow remote monitoring of electric appliances power consumption with a load of up to 16 A.
Installation

N - Neutral terminal
L - Live terminal (110–240 V AC)
O - Load circuit output terminal
Product Usage
Supported load types
Resistive (incandescent bulbs, heating devices)
Capacitive (capacitor banks, electronic equipment, motor start capacitors)
Inductive with RC Snubber (LED light drivers, transformers, fans, refrigerators, air-conditioners)
LED Signalisation
Normal mode
Removed/Excluded: The LED will be blinking blue in Mode 1 for 10 min after every power cycle and 10 min after S button pressed.
Added/Included: The LED will be blinking green in Mode 1 for 10 min after every power cycle and 10 min after S button pressed.
Settings in progress:
Factory reset and reboot: During factory reset, the LED will turn solid green for approx. 1sec, then the blue and red LED will be blinking 0,1s On, 0,1s Off for about 2sec.
Adding / Removing: During adding or removing, the LED will be blinking blue in Mode 2.
Firmware updating OTA: During the OTA update, the LED will be blinking blue and red in Mode 2.
Checking power supply 230 V AC frequency or 24 V DC voltage: During checking the power supply, the LED will be blinking blue and red in Mode 5.
Settings mode with S button:
Adding / Removing menu selected: When the menu is selected the LED will be on blue, for maximum of 10 seconds.
Adding / Removing menu - while pressing S- button - Add/Remove process selected: When the menu is executing the LED will be blinking blue in Mode 3.
Factory reset menu selected: When the menu is selected the LED will be on red, for maximum of 10 seconds.
Factory reset - while pressing S - button - Factory reset process selected: When the menu is executing the LED will be blinking red in Mode 3.
Alarm Mode:
Over-current detected
The LED will be blinking red in Mode 4 1x - 0,2s On 0,2s Off 2s Off and repeating this sequence
Overheat detected
The LED will be blinking red in Mode 4 2x - 0,2s On 0,2s Off 0,2s On 0,2s Off 2s Off and repeating this sequence
Power supply fault (power supply 230 V AC frequency or 24 V DC voltage fault)
The LED will be blinking red in Mode 4 3x - 0,2s On 0,2s Off 0,2s On 0,2s Off 0,2s On 0,2s Off 2s Off and repeating this sequence
Overvoltage detected
The LED will be blinking red in Mode 4 7x - 0,2s On 0,2s Off 0,2s On 0,2s Off 0,2s On 0,2s Off 0,2s On 0,2s Off 0,2s On 0,2s Off 0,2s On 0,2s Off 0,2s On 0,2s Off 2s Off and repeating this sequence
LED blinking modes:
Mode 1 0,5s On/2s Off
Mode 2 0,5s On/0,5s Off
Mode 3 0,1s On/0,1s Off
Mode 4 (1x to 6x - 0,2s On/0,2s Off) + 2s Off
Mode 5 0,2s On blue/0,2s On red
Reset to factory default |
1. To enter the Setting mode, quickly press and hold the S button on the Device until the LED turns solid blue. 2. Press the S button multiple times until the LED turns solid red. 3. Press and hold (> 2s) S button on the Device until the red LED starts blinking in Mode 3. Releasing the S button will start the factory reset. 4. During factory reset, the LED will turn solid green for about 1s, then the blue and red LED will start blinking in Mode 3 for approx. 2s. 5. The blue LED will be blinking in Mode 1 if the Factory reset is successful. |
Inclusion |
1. To enter the Setting mode, quickly press and hold the S button on the Device until the LED turns solid blue. 2. Quickly release and then press and hold (> 2s) the S button on the Device until the blue LED starts blinking in Mode 3. Releasing the S button will start the Learn mode. 3. The blue LED will be blinking in Mode 2 during the adding process. 4. The green LED will be blinking in Mode 1 if the Device is successfully added to a Z-Wave® network. |
Exclusion |
1. To enter the Setting mode, quickly press and hold the S button on the Device until the LED turns solid blue. 2. Quickly release and then press and hold (> 2s) the S button on the Device until the blue LED starts blinking in Mode 3. Releasing the S button will start the LEARN MODE. 3. The blue LED will be blinking in Mode 2 during the removing process. 4. The blue LED will be blinking in Mode 1 if the Device is successfully removed from a Z-Wave® network. |
NIF |
XXXNIF |
Wakeup |
XXXWakeupDescription |
Protection |
XXXProtection |
FirmwareUpdate |
XXXFirmwareUpdate |
SetAssociation |
XXXSetAssociation |
Association Groups:
Group Number |
Maximum Nodes |
Description |
1 |
9 |
Lifeline |
Configuration Parameters
Parameter 36: O (O1) Power report on change - percentage
This parameter determines the minimum change in consumed power that will result in sending new report to the main controller.
Size: 1 Byte, Default Value: 50
Setting |
Description |
0 |
reports are disabled |
1 - 100 |
% change in power |
Parameter 39: Minimal time between reports (O) O1
This parameter determines minimum time that has to elapse before sending new power report on O (O1) to the main controller.
Size: 1 Byte, Default Value: 30
Setting |
Description |
0 |
reports are disabled |
1 - 120 |
report interval in s |
Parameter 120: Factory Reset
Reset to factory default settings and removed from the z-wave network
Size: 4 Byte, Default Value: 0
Setting |
Description |
0 |
Don’t do Factory reset |
1431655765 |
Do the Factory reset (hex 0x55555555) |
Technical Data
Dimensions |
32 x 27 x 16 mm |
Weight |
13 gr |
Hardware Platform |
ZG23 |
EAN |
3800235269152 |
IP Class |
IP 20 |
Voltage |
230V |
Load |
16A |
Device Type |
Meter |
Firmware Version |
10.03 |
Z-Wave Version |
07.13 |
Z-Wave Product Id |
0x0460.0x0007.0x0081 |
Frequency |
Europe - 868,4 Mhz |
Maximum transmission power |
5 mW |