Single click the little button behind the battery cover one time to include or exclude the device. The device is FLIRS.
The Aeon Labs Smart Energy Monitor is a low-cost energy monitor for the entire home. It can wirelessly report immediate wattage and kWh usage to central control point gateways and can be easily and safely installed by anyone. Ease and safety are paramount: Electricians are not required to install the Aeon Labs Smart Energy Monitor; the customer never needs to handle hot exposed wiring. Current transformer clamps clamp around the AC Mains to detect energy usage for the entire house. The main body is anchored using a back mount which can be opend easily for battery replacement (every year). Optionally it is possible to power the unit from an external mini USB power supply. The device reports W and kWH.
The HEM can be placed on every dry place closed to the electric installation to be monitored. The current transformers need to be clamped around single wires. Attention: It is not possible to measure the current in cables that consist of more than one wire. Such a wire must be stripped and the CT is installed on the hot wire only. If there are less wires than the number of CTs this will not harm the operation of the device.
The device can be powered by batteries or by an external power supply that is connected to the HEM via mini USB connector. In case an external power supply is installed, remove the batteries inside!
The device is able to report wattage and electric power consumed on request or ? if configured correctly ? regularly with out being polled. The reporting interval is limited to min 4 minutes if the device is battery operated. The device reports aggregated values and individual values of the clamp. Attention: The wattage value is very dynamic and is measured right at the moment of polling. If both the aggregated value and the values of the individual clamps are polled the result may differ because the values were just taken at different times. In order to operate correctly, a number of configuration settings need to be made.
Configuration parameter #1 defines the local voltage. Attention: It is not possible to set the precise voltage of your mains network, but 110 verus 240 V only. The current transformer clamps will always measure current only and use the set voltage value to calculate the wattage and electric power. If your local main voltage is e.g. 230 V only, you will receive wrong wattage results simply by the fact that the wrong voltage is used for calculation.
Reset to factory default | XXXResetDescription |
Inclusion | Single click the little button behind the battery one time to include or exclude the device. |
Exclusion | Single click the little button behind the battery one time to include or exclude the device. |
NIF | A single click on the little button behind the battery sends a Node Information Frame. |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Receiver of all Reports |
Size: 1 Byte, Default Value: 00
Setting | Description |
---|---|
00 | Disabled |
01 | Enabled |
Size: 1 Byte, Default Value: 00
Setting | Description |
---|---|
00 | Disabled |
01 | Enabled |
The value represents the minimum change in Wattage for a Report to be sent . Size: 2 Byte, Default Value: 0032
Setting | Description |
---|---|
00 - 6000 | Value in W |
The value represents the minimum change in Wattage for a Report to be sent . Size: 2 Byte, Default Value: 0032
Setting | Description |
---|---|
00 - 6000 | Value in W |
The value represents the minimum change in Wattage for a Report to be sent . Size: 2 Byte, Default Value: 0032
Setting | Description |
---|---|
00 - 6000 | Value in W |
The value represents the minimum change in Wattage for a Report to be sent . Size: 2 Byte, Default Value: 0032
Setting | Description |
---|---|
00 - 6000 | Value in W |
The value represents the minimum change in Watage Percent for a report to be sent Size: 1 Byte, Default Value: 0a
Setting | Description |
---|---|
00 - 100 | Value in % |
The value represents the minimum change in Watage Percent for a report to be sent Size: 1 Byte, Default Value: 0a
Setting | Description |
---|---|
00 - 100 | Value in % |
The value represents the minimum change in Watage Percent for a report to be sent Size: 1 Byte, Default Value: 0a
Setting | Description |
---|---|
00 - 100 | Value in % |
The value represents the minimum change in Watage Percent for a report to be sent Size: 1 Byte, Default Value: 0a
Setting | Description |
---|---|
00 - 100 | Value in % |
Size: 1 Byte, Default Value: 00
Setting | Description |
---|---|
00 | Disabled |
01 | Enabled |
Defines the type of report sent for the Reporting Group 1. Size: 4 Byte, Default Value: 00000008
Setting | Description |
---|---|
Byte 1: 00000010 | Battery Report |
Byte 1: 00000100 | MultiSensor Report for the whole device |
Byte 1: 00001000 | Meter Report for Watt for the whole device |
Byte 1: 00010000 | Meter Report for kWh for the whole device |
Byte 2: 00000010 | Meter Report for Watt for clamp 1 |
Byte 2: 00000100 | Meter Report for Watt for clamp 2 |
Byte 2: 00001000 | Meter Report for Watt for clamp 3 |
Byte 2: 00010000 | Meter Report for kWh for clamp 1 |
Byte 2: 00100000 | Meter Report for Watt for clamp 2 |
Byte 2: 01000000 | Meter Report for kWh for clamp 3 |
Defines the type of report sent for the Reporting Group 2. Size: 4 Byte, Default Value: 00000000
Setting | Description |
---|---|
Byte 1: 00000010 | Battery Report |
Byte 1: 00000100 | MultiSensor Report for the whole device |
Byte 1: 00001000 | Meter Report for Watt for the whole device |
Byte 1: 00010000 | Meter Report for kWh for the whole device |
Byte 2: 00000010 | Meter Report for Watt for clamp 1 |
Byte 2: 00000100 | Meter Report for Watt for clamp 2 |
Byte 2: 00001000 | Meter Report for Watt for clamp 3 |
Byte 2: 00010000 | Meter Report for kWh for clamp 1 |
Byte 2: 00100000 | Meter Report for Watt for clamp 2 |
Byte 2: 01000000 | Meter Report for kWh for clamp 3 |
Defines the type of report sent for the Reporting Group 3. Size: 4 Byte, Default Value: 00000000
Setting | Description |
---|---|
Byte 1: 00000010 | Battery Report |
Byte 1: 00000100 | MultiSensor Report for the whole device |
Byte 1: 00001000 | Meter Report for Watt for the whole device |
Byte 1: 00010000 | Meter Report for kWh for the whole device |
Byte 2: 00000010 | Meter Report for Watt for clamp 1 |
Byte 2: 00000100 | Meter Report for Watt for clamp 2 |
Byte 2: 00001000 | Meter Report for Watt for clamp 3 |
Byte 2: 00010000 | Meter Report for kWh for clamp 1 |
Byte 2: 00100000 | Meter Report for Watt for clamp 2 |
Byte 2: 01000000 | Meter Report for kWh for clamp 3 |
Defines the time interval when the defined report of Reporting Group 1 is sent out. Size: 1 Byte, Default Value: 01
Setting | Description |
---|---|
00 - 127 | Value in s |
Defines the time interval when the defined report of Reporting Group 2 is sent out. Size: 1 Byte, Default Value: 01
Setting | Description |
---|---|
00 - 127 | Value in s |
Defines the time interval when the defined report of Reporting Group 3 is sent out. Size: 1 Byte, Default Value: 01
Setting | Description |
---|---|
00 - 127 | Value in s |
Size: 1 Byte, Default Value: 01
Setting | Description |
---|
Size: 1 Byte, Default Value: 01
Setting | Description |
---|
(0= Aeon Labs Standard Product, 1= AT&T). Size: 1 Byte, Default Value: 01
Setting | Description |
---|
0 =disable, 1 = enable Size: 1 Byte, Default Value: 00
Setting | Description |
---|---|
00 | 0 = disabled |
01 | 1 = enabled |
Size: 2 Byte, Default Value: 0000
Setting | Description |
---|
Reset configuration set up to default setting Size: 1 Byte, Default Value: 00
Setting | Description |
---|
Device Type | Routing Multilevel Sensor |
Generic Device Class | Multilevel Sensor |
Specific Device Class | Routing Multilevel Sensor |
Firmware Version | 03.38 |
Z-Wave Version | 02.61 |
Z-Wave Product Id | 0086.0002.0009 |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |