The AEOTEC Water Sensor 7 Basic is a sensor, which detects water leakage. The sensor is easily retrofittable.
Thanks to its slim design the AEOTEC Water Sensor 7 Basic can be installed in any bathroom, behind a kitchen sink or in any other tight space. The sensor just has to be installed on the wall and the sensor probe must be put on the floor.
Tripple clicking the tamper button includes (adds) and excludes (removes) the device. A single click on the button will wake up the device. The device supports the Z-Wave Security S2 framework with authenticated and unauthenticated network keys. Please follow the instructions on the central controller when including. The device also supports Smart Start.
The sensor can be mounted on the wall. Mounting can be accomplished either using the tape by peeling off the protection foil or using two screws with the holes inside the battery compartment.
Water Sensor probe which is hardwired to the Main Unit must be put on the floor or onto any other surface, where water leakage must be detected.
Once installed the sensor will report Leakage Detected and No Leakage status changes to a central Z-Wave controller using notification commands. Additionally, the sensor can directly control other devices using the association group 2. The device is protected by a tamper switch.
Water leakage detection
The water leakage detection allows reporting as soon as water hits the sensor probe. This is accomplished using the command class notification - water alarm - water leakage detected unknown location. After the leakage has stopped (the sensor probes are not short-connected through the water) the device reports this to the central controller.
Link testing
When activated by configuration parameter #4 the device can perform a link test with device No.1. Double-clicking the tamper will start the process. As a result, the GREEN LED will blink one time in case of success and RED LED will blink three times in case of failure.
The device sends the following notifications to the central controller:
Reset to factory default | Once Cover is removed and the tamper switch is tripped, push the tamper for 5 seconds until the RED LED blinks once. Then release tamper and push it again for 5 seconds while the RED LED is blinking until the GREEN LED blinks once. |
Inclusion | 1. Open the housing. 2. Remove the battery protection. 3. Press the tamper on the side of the appliance three times quickly. |
Exclusion | 1. Open the housing. 2. Press the tamper on the side of the appliance three times quickly. |
NIF | Press the tamper once |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | Wake Up the device by removing the cover. Then hit the tamper switch once. |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Lifeline |
2 | 5 | Control devices when water leakage is detected |
3 | 5 | Sends out alarm message when water leakage is detected |
4 | 5 | Sends out alarm messages when tamper is tripped |
This parameter defines when LEDs will indicate events. Disabling all indications may extend battery life.
Value 0 means - No Indications.
Size: 1 Byte, Default Value: 7 (values 1 + 2 + 4 summarized)
Setting | Description |
---|---|
1 | Water Leakage Status Change |
2 | Wake Up |
4 | Device Tampering |
Allows to enable the activation of a Z-Wave range test with double clicking the tamper switch. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disabled |
1 | Enabled |
This parameter defines the status of the water leakage that causes sending a BASIC command to all devices of Association Group 2. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Switch after Water Leakage Start and Stop |
1 | Switch after Water Leakage Start |
2 | Switch after Water Leakage Stop |
This parameter defines which commands is sent to 2nd Association Group Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | On |
1 | Off |
2 | On and Off |
This is the BASIC command value sent in case of On event. Size: 1 Byte, Default Value: 255
Setting | Description |
---|---|
0 - 99 | Value |
255 | Value |
This is the BASIC command value sent in case of Off event. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 99 | Value |
255 | Value |
On command is sent after a delay defined in this parameter. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 32400 | seconds |
Off command is sent after a delay defined in this parameter. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 32400 | seconds |
Time a tamper alarm is delayed. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 32400 | seconds |
This parameter defines if the alarm cancellation event is reported. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Do not send Report |
1 | Send Report |
Backwards compatibility, Binary Sensor for door/window state. (Sensor type=0x0A) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable |
1 | Enable |
Size: 1 Byte, Default Value: 20
Setting | Description |
---|---|
10 - 50 | % |
Size: 1 Byte, Default Value: 24
Setting | Description |
---|---|
0 | Disable |
1 - 255 | Hours |
This parameter helps reset configuration parameters and the device to factory defaults Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
1 - 1431655764 (0x55555554) | Reset all Parameter settings to their default settings. |
1431655765 (0x55555555) | Completely factory reset sensor and send device reset locally notification |
Dimensions | 28x95x35 mm |
Hardware Platform | ZGM130S |
EAN | 1220000016705 |
IP Class | IP 20 |
Battery Type | 1 * 1/2 AA |
Device Type | Notification Sensor |
Generic Device Class | Sensor Notification |
Specific Device Class | Routing Sensor Notification |
Network Operation | Reporting Sleeping Slave |
Firmware Version | 02.00 |
Z-Wave Version | 07.12 |
Z-Wave Product Id | 0371.0002.0012 |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |