This is a
The AEOTEC Door/Window Sensor 7 Pro is a sensor, which detects if your window is opened, closed or tilted. The sensor is easily retrofittable. Furthermore, the AEOTEC Door/Window Sensor can include other sensors by being connected with other binary sensors like NTC contacts, microswitches or flood sensors.
Thanks to its slim design the AEOTEC Door/Window Sensor 7 Pro can be installed unflashy on every window. The sensor just has to be installed on the window casement. Additionally, there has to be a slim magnet installed closely to the sensor at the window frame. By using a patented method the sensor can reliably detect the exact position of the window.
With the potential free input, the Door/Window Sensor can also include other sensors in your Z-Wave system. For that, the binary sensor is connected to the potential free input of the sensor. Besides sensors, there can also be connected momentary switches, which control scenes in your gateway.
Tripple clicking the tamper button includes (adds) and excludes (removes) the device. A single click on the button will wake up the device. The device supports the Z-Wave Security S2 framework with authenticated and unauthenticated network keys. Please follow the instructions on the central controller when including. The device also supports Smart Start.
The sensor can be mounted either on the moving part or on the fixed part of a door or a window. Mounting can be accomplished either using the tape by peeling off the protection foil or using two screws with the holes inside the battery compartment. If the tilt detection on a window (only normal windows, no roof windows) shall be used the sensor device must be placed on the moving part of the window and the magnet on the window frame. The sensor comes with two types of magnets:
Once installed the sensor will report "open" and "close" status changes to a central Z-Wave controller using notification commands. Additionally, the sensor can directly control other devices using association group 2. Using configuration commands the source of "open" and "close" events can be chosen between the internal magnet detector or external dry contact connected via the screw terminal. The device is protected by a tamper switch.
Tilt detection
The tilt detection allows reporting the way a window is opened. This is accomplished using the command class "binary sensor - tilt-type". In case the window is closed or opened without tilting the tilt sensor will report "Off". In case the window is tilted an "On" is reported. The angle of inclination of the window must be at least 5°.
Screw Terminal
The product must support the interconnection of external sensors as well as actuators and dry-contacts. The product allows interconnection with external sensors/actuators via 4-pin screw terminals with the following pinout:
Reset to factory default | Once Cover is removed and the tamper switch is tripped, push the tamper for 5 seconds until the RED LED blinks once. Then release tamper and push it again for 5 seconds while the RED LED is blinking until the GREEN LED blinks once. |
Inclusion | 1. Open the housing. 2. Remove the battery protection. 3. Press the tamper on the side of the appliance three times quickly. |
Exclusion | 1. Open the housing. 2. Press the tamper on the side of the appliance three times quickly. |
NIF | Press the tamper once |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | Wake Up the device by removing the cover. Then hit the tamper switch once. |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Lifeline |
2 | 5 | Control devices when a magnet or external dry contacts trips |
3 | 5 | Sends out alarm message when a magnet or external dry sensor trips |
4 | 5 | Sends alarm messages when tamper is tripped |
5 | 5 | Control devices when tilting sensor trips |
This parameter defines if the internal magnet sensor or the external terminal input is detected and used to issue alarm notification. There is always one input active only. The other sensor input the deactivated. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Internal Magnet Sensor Used |
1 | External Terminal Inputs Used |
Parameter defines how dry contact will operate with the sensor or switch that is connected to the dry contact terminals. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | NO Toggle / Follow state will follow the input of the dry contact terminals where OFF is CLOSED, and ON is OPEN. |
1 | NC Toggle / Follow state will follow the input of the dry contact terminals where ON is CLOSED, and OFF is OPEN. |
2 | NO save state will allow state of sensor to toggle OPEN/CLOSE based on OFF to ON signal. |
3 | NC save state will allow state of sensor to toggle OPEN/CLOSE based on ON toOFF signal. |
This parameter allows to set in what state is door/window when the magnet is close to the sensor. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Closed when Magnet near |
1 | Opened when Magnet near |
This parameter defines when the red LED will indicate events. Disabling all indications may extend battery life. Value 0 means no indications. Size: 1 Byte, Default Value: 7 (values 1 + 2 + 4 summarized)
Setting | Description |
---|---|
1 | Open/Close Status Change |
2 | Wake Up |
4 | Device Tampering |
Allows to enable the activation of a Z-Wave range test with double clicking the tamper switch. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disabled |
1 | Enabled |
This parameter defines the status of the magnet switch that causes sending a BASIC command to all devices of Association Group 2. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Switch after Open and Close |
1 | Switch after Open |
2 | Switch after Close |
This parameter defines which commands is sent to 2nd Association Group Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | On |
1 | Off |
2 | On and Off |
This is the BASIC command value sent in case of On event. Size: 1 Byte, Default Value: 255
Setting | Description |
---|---|
0 - 99 | Value |
255 | Value |
This is the BASIC command value sent in case of Off event. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 99 | Value |
255 | Value |
On command is sent after a delay defined in this parameter. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 32400 | seconds |
Off command is sent after a delay defined in this parameter. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 32400 | seconds |
Time a tamper alarm is delayed. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 32400 | seconds |
This parameter defines if the alarm cancellation event is reported. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Do not send Report |
1 | Send Report |
This parameter enables/disables the central scene function. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disabled |
1 | Enabled |
This parameter enables/disables the tilt function.
n
Setting | Description |
---|---|
0 | Disabled |
1 | Enabled |
2 | Tilt without magnet (from version 2.0) |
This parameter allows to set in what state is door/window when the tilt is in an OFF state. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | OFF when sensor is vertical |
1 | ON when sensor is vertical |
This parameter defines the status of the magnet switch that causes sending a BASIC command to all devices of Association Group 5. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Switch after Open and Close |
1 | Switch after Open |
2 | Switch after Close |
This parameter defines which commands is sent to 5th Association Group Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | On |
1 | Off |
2 | On and Off |
This is the BASIC command value sent in case of On event. Size: 1 Byte, Default Value: 255
Setting | Description |
---|---|
0 - 99 | Value |
255 | Value |
This is the BASIC command value sent in case of Off event. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 99 | Value |
255 | Value |
With this parameter, you can adjust the tilt sensitivity if the tilt is too low or too strong. Value 0 does not disable Tilt Sensor, it just sets it to a minimum. Size: 1 Byte, Default Value: 50
Setting | Description |
---|---|
0 - 100 | Sensitivity |
Backwards compatibility, Binary Sensor for door/window state. (Sensor type=0x0A) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable |
1 | Enable |
Size: 1 Byte, Default Value: 20
Setting | Description |
---|---|
10 - 50 | % |
Size: 1 Byte, Default Value: 24
Setting | Description |
---|---|
0 | Disable |
1 - 255 | Hours |
This parameter helps reset configuration parameters and the device to factory defaults Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
1 - 1431655764 | Reset all Parameter settings to their default settings. |
1431655765 | Completely factory reset sensor and send device reset locally notification. |
Dimensions | 28x95x35 mm |
Hardware Platform | ZGM130S |
EAN | 1220000016682 |
IP Class | IP 20 |
Battery Type | 1 * 1/2 AA |
Device Type | Notification Sensor |
Generic Device Class | Sensor Notification |
Specific Device Class | Routing Sensor Notification |
Network Operation | Reporting Sleeping Slave |
Firmware Version | 02.00 |
Z-Wave Version | 07.12 |
Certification ID | ZC12-20060075 |
Z-Wave Product Id | 0371.0002.000C |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |