This is a
Turn the primary controller of Z-Wave network into inclusion mode, short press the products Action Button that you can find on the product.
Aeotec by Aeon Labs Water Sensor 6 brings intelligence to a new level, one that is suited to both safety and convenience. It contains 4 sensing points, which would be more accurately to detect the presence and absence of water or detect whether there is water leak in some places of your home. The Water Sensor 6 has an inbuilt buzzer that can play alarm sounds to let you know when the water is detected. The Water Sensor 6 is also a security Z-Wave device that supports Over The Air (OTA) for firmware updates.
The final installation steps of Water Sensor 6 are very simple, all you need to do is choose the area that you want Water Sensor 6 to monitor leaks or floods in.
Water Sensor 6 is optimally placed on a flat surface where floods, leaks and drips can occur; these can include your washroom or kitchen. When placing it, ensure that its detection probes touch the surface being monitored; when water touches any 2 of the 4 probes on Water Sensor 6 an alert will be sent to your Z-Wave network. Below are some of the possible situations that can trigger Water Sensor 6.
1. Water is detected by sensing point 2 and 4.
2. Water is detected by sensing point 1 and 3.,
3. Water is detected by sensing point 1 and 2.
4. Water is detected by sensing point 3 and 4.
5. Water is detected by sensing point 1, 2, 3 and 4.
These situations will cause Water Sensor 6 to send a water presence or trigger event to your gateway. Should water clear from the area where Water Sensor 6 is installed, the sensor will also send a separate command to your Z-Wave gateway informing it that there is no more water in the area.
Testing Health Connectivity.
Note - Health test does not test for routing communication health, only tests for direct communication with your gateway to determine if it has a healthy direct connection.
You can determine the health of your Water Sensor 6s connectivity to your gateway using a manual button press, hold, and release function which is indicated by the LED color.
1. Press and hold Water Sensor 6 Action button
2. Wait until the RGB LED turns into a Purple Color
3. Release Water Sensor 6 Action Button
The RGB LED will blink its Purple color while sending ping messages to your gateway, when it has finished, it will blink 1 of 3 colors:
Red = Bad HealthYellow = Moderate Health
Yellow = Moderate Health
Green = Great Health
Replacing your sensors battery.
Your Water Sensor 6 uses 1x CR123A battery that has a 2 year battery life maximum. Ultimately the battery life of the sensor will highly depend on the uses and settings of Water Sensor. When battery power has depleted, below are the steps you can take to replace the battery in your Water Sensor 6.
1. Unscrew the 2 screws from Water Sensor 6. On the rear of Water Sensor 6 you‘ll find 2 screws in opposing corners.
2. Separate the battery cover from the Sensor unit. Use the separation tool to separate the battery cover by pushing or moving the separation along the gap between the battery cover and the sensor unit.
a. Pull open a small gap between the battery cover and Sensor unit.
b. Push or move your fingernail along the gap between the battery cover and Sensor unit.
3. Once the battery cover is separated from the Sensor Unit, you can pull out and change the battery located in the center of the Water Sensor 6 hardware.
Reset to factory default |
|
Inclusion | 1. Remove the battery protector.
2. Press the button on the unit once |
Exclusion | 1. Press the button on the unit once |
NIF | Press the Z-Wave Button |
Wakeup | Pressing the Action Button once will trigger sending the Wake up notification command. If press and hold the Z-Wave button for 3 seconds, the Water Sensor will wake up for 10 minutes. |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Lifeline group.1. The Battery Report or Multilevel Sensor Report (Configurable) can be sent to the associated nodes in group 1.2. When the water leak is detected, the Notification Report will be send to the associated nodes in group 1.3. When the Water Sensor is reset, the Device Reset Locally CC will be send to the associated nodes in group 1. |
2 | 5 | Send the configuration parameter 136 (0x88) to the associated nodes in group 2. |
3 | 5 | Send Basic Set (configured by parameter 88 (0x58) to the associated nodes in Group 3 when the Sensor probe 1 is triggered. |
4 | 5 | Send Basic Set (configured by parameter 89 (0x59) to the associated nodes in Group 4 when the Sensor probe 2 is triggered. |
Enable/Disable waking up for 10 minutes when re-power on (battery mode) the MultiSensor. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable |
1 | Enable. |
Set the timeout of awake after the Wake Up CC is sent out.. Size: 1 Byte, Default Value: 30
Setting | Description |
---|---|
8 - 127 | Available rang is 8 to 127 seconds. |
Report the current power mode and the product state for battery power mode.Note: this parameter cannot be used as Set usage. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 | USB power mode |
256 | Keep sleep state for Battery power mode |
257 | Keep awake for 10 minutes for battery power mode. |
Set the alarm time for the Buzzer when the sensor is triggered. Size: 4 Byte, Default Value: 101968650
Setting | Description |
---|---|
1 - 255 | Repeated cycle of Buzzer alarm. |
256 - 65535 | the time of Buzzer keeping ON state (MSB) |
65536 - 2147483647 | The time of Buzzer keeping OFF state |
Configure the default low battery value. When the current battery level is lower than this value, it will send out the low battery alarm. Size: 1 Byte, Default Value: 20
Setting | Description |
---|---|
10 - 50 | Available rang is 10% to 50%. |
Enable/disable the sensor report Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable |
1 | Notification Report for Water Leak event |
2 | Notification Report for Vibration event |
4 | Configuration Report for Tilt sensor |
16 | Notification Report for Under heat alarm |
32 | Notification Report for Overheat alarm |
Set the upper limit value (overheat). Size: 4 Byte, Default Value: 68157696
Setting | Description |
---|---|
0 | Celsius unit |
1 | Fahrenheit unit |
65536 - 2147483647 | Temperature value |
Set the lower limit value (under heat) Size: 4 Byte, Default Value: 20971776
Setting | Description |
---|---|
0 | Celsius unit |
1 | Fahrenheit unit |
65536 - 2147483647 | Temperature value |
Note:1. When the current measurement <= (Upper limit - Recover limit), the upper limit report is enabled and then it would send out a sensor report when the next measurement is more than the upper limit. After that the upper limit report would be disabled again until the measurement <= (Upper limit - Recover limit).2. When the current measurement >= (Lower limit + Recover limit), the lower limit report is enabled and then it would send out a sensor report when the next measurement is less than the lower limit. After that the lower limit report would be disabled again until the measurement >= (Lower limit + Recover limit).3. High byte is the recover limit value. Low byte is the unit (0x01=Celsius, 0x02=Fahrenheit). Size: 2 Byte, Default Value: 5121
Setting | Description |
---|---|
10 - 255 | Available rang is 1.0°C to 25.5°C |
Set the default unit of the automatic temperature report in parameter 101-103. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | The unit is Celsius. |
1 | The unit is Fahrenheit. |
Get the state of tilt sensor.Note: this is a Get-only parameter. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | The Water Sensor main unit is in horizontal direction. |
1 | The Water Sensor main unit is in vertical direction. |
Enable/ disable the buzzer. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Disable |
1 | Enable |
To set which sensor is triggered the buzzer will alarm. Size: 4 Byte, Default Value: 55
Setting | Description |
---|---|
1 | If the Water leak is triggered, the buzzer will alarm. |
2 | If the vibration is triggered, the buzzer will alarm. |
4 | If the tilt sensor is triggered, the buzzer will alarm. |
16 | If the under heat is triggered, the buzzer will alarm |
32 | If the overheat is triggered, the buzzer will alarm. |
To set which value of the Basic Set will be sent to the associated nodes in association Group 3 when the Sensor probe 1 is triggered. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Send nothing |
1 | Presence of water, send Basic Set 255 (0xFF), absence of water, send Basic Set 0 (0x00). |
2 | Presence of water, send Basic Set 0 (0x00), absence of water, send Basic Set 255 (0xFF). |
To set which value of the Basic Set will be sent to the associated nodes in association Group 4 when the Sensor probe 2 is triggered. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Send nothing. |
1 | Presence of water, send Basic Set 255 (0xFF), absence of water, send Basic Set = 0 (0x00). |
2 | Presence of water, send Basic Set 0 (0x00), absence of water, send Basic Set 255 (0xFF). |
To set which power source level is reported via the Battery CC. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | report the USB power level. |
1 | report the CR123A battery level. |
To set what unsolicited report would be sent to the Lifeline group. Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
0 | Send Nothing |
1 | Battery Report is enabled. |
2 | Multilevel sensor report for temperature is enabled. |
3 | Battery Report and Multilevel sensor report for temperature are enabled. |
To set the interval time of sending reports in Report group 1.Note:1. The unit of interval time is second if USB power.2. If battery power, the minimum interval time is equal to Wake Up interval set by the Wake Up CC. Size: 4 Byte, Default Value: 3600
Setting | Description |
---|---|
5 - 2678400 | Available rang is 5 to 2678400 seconds. |
To set which sensor report can be sent when the water leak event is triggered and if the receiving device is a non-multichannel device. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Send nothing |
1 | Send notification report to association group 1. |
2 | Send configuration 136 (0x88) report to association group 2. |
3 | Send notification report to association group 1 and Send configuration 136 (0x88) report to association group 2. |
When the parameter 135 (0x87) is set to 2 or 3, it can get the sensor probes status through this configuration value.Note: This parameter is a Get- only parameter. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | absence of water is triggered by probe 1. |
1 | presence of water is triggered by probe 1. |
2 | presence of water is triggered by probe 2. |
Temperature sensor calibration.Note:1. High byte is the calibration value. Low byte is the unit (0 (0x00)=Celsius, 1 (0x01)=Fahrenheit)2. The calibration value (high byte) contains one decimal point. E.g. if the value is set to 20 (0x1400), the calibration value is 2.0 °C (EU/AU version) or if the value is set to 20 (0x1401), the calibration value is 2.0 °F(US version) 3. The calibration value (high byte) = standard value - measure value.E.g. If measure value =25.3°C and the standard value = 23.2°C, so the calibration value= 23.2°C - 25.3°C= -2.1°C (0xEB).If the measure value =30.1°C and the standard value = 33.2°C, so the calibration value= 33.2°C - 30.1°C=3.1°C (0x1F). Size: 2 Byte, Default Value: 1
Setting | Description |
---|---|
-128 - 127 | Available rang is -12.8°C to 12.7°C. |
Enable/disable all configuration parameters to be locked. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable |
1 | Enable. |
Reset to factory defaults. Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
1 | Reset all configuration parameters to factory defaults. |
1431655765 | Reset the product to factory defaults. |
Dimensions | 0.0380000x0.0850000x0.0240000 mm |
Weight | 62 gr |
Hardware Platform | ZM5101 |
EAN | 1220000015258 |
IP Class | IP 65 |
Battery Type | 1 * CR123A |
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Z-Wave Version | 6.51.09 |
Certification ID | ZC10-17055615 |
Z-Wave Product Id | 0x0086.0x0002.0x007A |
Firmware Updatable | Updatable by Consumer by RF |
IP (Ingress Protection) Rated | ok |
Sensors | Air TemperatureWater Flow |
Supported Notification Types | Heat AlarmHome SecurityWater Alarm |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |