Quickstart

This is a secure Sub Energy Meter for XXXQFrequencyName. To run this device please connect it to your mains power supply. Turn the primary controller of Z-Wave network into inclusion mode, short press the product’s Action button that you can find on the product's housing.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

Aeon Labs Home Energy Meter Gen5 is a Z-Wave device that can monitor the total amount of electricity of your home.
It can report the wattage energy usage and KWH usage to a Z-Wave Controller (especially a gateway). In near real-time you’ll have a full understanding of how much electricity you use and when you use it.
Products that are Z-Wave certified can be used and communicate with other Z-Wave certified devices. Also a tool that can be programmed, scheduled, controlled and communicated with from anywhere in the world.

Reset to factory default Press and hold the Action button that you can find on the product's housing for 10 seconds and then release. This procedure should only be used when the primary controller is inoperable.
Inclusion Turn the primary controller of Z-Wave network into inclusion mode, short press the product’s Action button that you can find on the product's housing.
Exclusion Turn the primary controller of Z-Wave network into exclusion mode, short press the product’s Action button that you can find on the product's housing.
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Z-Wave Plus Lifeline. The automatic reports (configured by parameter 101/102/103) can be sent to the associated nodes in association group 1.

Configuration Parameters

Parameter 10: Percentage change in wattage to induce a automatic report

Percentage change in wattage to induce a automatic report for the power report of Clamp 2.
Size: 1 Byte, Default Value: 10

Setting Description
0 - 100 The available range is 0 to 100.

Parameter 101: To set which report need to be sent.

To set which report need to be sent in Report group 1.
Size: 4 Byte, Default Value: 2

Setting Description
1 Report Accumulated kWh of whole HEM
2 Report Instantaneous Watts of whole HEM.
4 Report Instantaneous Voltage of whole HEM.
8 Report Instantaneous Current (Amperes) of whole HEM.
256 Report Instantaneous Watts of Channel 1.
768 Report Instantaneous Watts of Channel 2.
2048 Report Accumulated kWh of Channel 1.
4096 Report Accumulated kWh of Channel 2.
65535 Report Instantaneous Voltage of Channel 1.
196608 Report Instantaneous Voltage of Channel 2.
524288 Report Instantaneous Current (Amperes) of Channel 1.
1048576 Report Instantaneous Current (Amperes) of Channel 2.

Parameter 102: To set which report need to be sent.

To set which report need to be sent in Report group 2.
Size: 4 Byte, Default Value: 1

Setting Description
1 Report Accumulated kWh of whole HEM
2 Report Instantaneous Watts of whole HEM.
4 Report Instantaneous Voltage of whole HEM.
8 Report Instantaneous Current (Amperes) of whole HEM.
256 Report Instantaneous Watts of Channel 1.
768 Report Instantaneous Watts of Channel 2.
2048 Report Accumulated kWh of Channel 1.
4096 Report Accumulated kWh of Channel 2.
65535 Report Instantaneous Voltage of Channel 1.
196608 Report Instantaneous Voltage of Channel 2.
524288 Report Instantaneous Current (Amperes) of Channel 1.
1048576 Report Instantaneous Current (Amperes) of Channel 2.

Parameter 103: To set which report need to be sent.

To set which report need to be sent in Report group 3.
Size: 4 Byte, Default Value: 0

Setting Description
1 Report Accumulated kWh of whole HEM
2 Report Instantaneous Watts of whole HEM.
4 Report Instantaneous Voltage of whole HEM.
8 Report Instantaneous Current (Amperes) of whole HEM.
256 Report Instantaneous Watts of Channel 1.
768 Report Instantaneous Watts of Channel 2.
2048 Report Accumulated kWh of Channel 1.
4096 Report Accumulated kWh of Channel 2.
65535 Report Instantaneous Voltage of Channel 1.
196608 Report Instantaneous Voltage of Channel 2.
524288 Report Instantaneous Current (Amperes) of Channel 1.
1048576 Report Instantaneous Current (Amperes) of Channel 2.

Parameter 111: Set the interval time of sending report.

Set the interval time of sending report in Report group 1.
Size: 4 Byte, Default Value: 5

Setting Description
0 - 268435456 Interval Seconds

Parameter 112: Set the interval time of sending report.

Set the interval time of sending report in Report group 2.
Size: 4 Byte, Default Value: 120

Setting Description
0 - 268435456 Interval Seconds

Parameter 113: Set the interval time of sending report.

Set the interval time of sending report in Report group 3.
Size: 4 Byte, Default Value: 120

Setting Description
0 - 268435456 Interval Seconds

Parameter 2: Set the energy detection mode for parameter 101 to 103.

Set the energy detection mode for the measure reports of parameter 101 to 103.
Size: 1 Byte, Default Value: 0

Setting Description
0 Report absolute value for power and energy measurements.
1 Report positive/negative power and report the algebraic sum energy
2 Report positive/negative power and only report energy positive part (consuming electricity)
3 Report positive/negative power and only report energy negative part (generating electricity).

Parameter 200: Partner ID

Partner ID.
Size: 1 Byte, Default Value: 0

Setting Description
0 Aeon Labs Standard Product
1 - 127 Partner ID of Partner Product

Parameter 252: Enable/Disable Lock Configuration

Enable/Disable Lock Configuration.
Size: 1 Byte, Default Value: 0

Setting Description
0 All configuration parameters are configurable.
1 All configuration parameters are not configurable (Locked)

Parameter 255: Reset to default factory setting

Reset to default factory setting.
Size: 4 Byte, Default Value: 0

Setting Description
1 Resets all configuration parameters to default setting.
1431655765 Reset the product to default factory setting and be excluded from the Z-wave network

Parameter 3: Enable/disable selective reporting only when power change reaches a certain threshold or percentage

Enable/disable selective reporting only when power change reaches a certain threshold or percentage set in parameter 4 to 11.
Size: 1 Byte, Default Value: 1

Setting Description
0 Disable
1 Enable.

Parameter 4: Threshold change in wattage to induce a automatic report

Threshold change in wattage to induce a automatic report for total power report.
Size: 2 Byte, Default Value: 50

Setting Description
0 - 60000 The available range is 0 to 60000.

Parameter 5: Threshold change in wattage to induce a automatic report

Threshold change in wattage to induce a automatic report for the power report of Clamp 1.
Size: 2 Byte, Default Value: 50

Setting Description
0 - 60000 The available range is 0 to 60000.

Parameter 6: Threshold change in wattage to induce a automatic report

Threshold change in wattage to induce a automatic report for the power report of Clamp 2.
Size: 2 Byte, Default Value: 50

Setting Description
0 - 60000 The available range is 0 to 60000.

Parameter 8: Percentage change in wattage to induce a automatic report

Percentage change in wattage to induce a automatic report for total power report.
Size: 1 Byte, Default Value: 10

Setting Description
0 - 100 The available range is 0 to 100.

Parameter 9: Percentage change in wattage to induce a automatic report

Percentage change in wattage to induce a automatic report for the power report of Clamp 1.
Size: 1 Byte, Default Value: 10

Setting Description
0 - 100 The available range is 0 to 100.

Technical Data

Dimensions 29x90x11 mm
Weight 18 gr
Hardware Platform ZM5202
EAN 1220000012813
Device Type Sub Energy Meter
Network Operation Always On Slave
Z-Wave Version 6.51.06
Certification ID ZC10-15120010
Z-Wave Product Id 0x0086.0x0002.0x005F
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW
EuropeSub Energy Meter