This is a
A.) Slide the base unit from the mounting plate and remove the safety strip from the battery compartment
B.) Click the + (Add) button in your Z-Wave App and follow the further instructions
C.) Press the Network-button 3 times within 1.5 seconds and the Status-LED on the base unit front will flash 3 times. The App will show if the Add device process was successful and the Status-LED will turn off. Repeat the inclusion process from step B if it was not successful.
The ABUS Z-Wave Smoke detector provides reliable warning of risk of potentially fatal smoke inhalation and sounds an alarm. Its compact design does not compromise the functionality but even convinces with low maintenance due to 5 years of battery life. The Smoke detector also includes a test button for manual self-testing, for test alarms and temporary muting.
- Flat ceiling mounting
The preferred location to install smoke sensor is in the centre of the ceiling, because smoke, heat and combusible products rise to ceiling and will laterally spread. Keep at least 30 cm distance from lights or decoration and at least 17cm away from walls and corners.
- Sloping ceiling mounting
If ceiling is sloping, please install the smok sensor at horizontal distance 90 cm away from the ceiling top.
Installation guide
- Anticlockwise rotation the bracket out from the installation base.
- Fixed the bracket intoceiling using srews.
- Remove the double-sided adhersive and stickalarm into ceiling
- Remove the battery insulating strip to make detector on power and clockwise rotating alarm into bracket.
Reset to factory default | 1. Remove the battery 2. Press the Network button and keep it pressed while inserting the battery again. 3. Device will restore factory settings |
Inclusion | A.) Slide the base unit from the mounting plate and remove the safety strip from the battery compartment B.) Click the + (Add) button in your Z-Wave App and follow the further instructions C.) Press the Network-button 3 times within 1.5 seconds and the Status-LED on the base unit front will flash 3 times. The App will show if the Add device process was successful and the Status-LED will turn off. Repeat the inclusion process from step B if it was not successful. |
Exclusion | A.) Click the - (Remove) button in your Z-Wave App and follow the further instructions. B.) Press the Network-button 3 times within 1.5 seconds and the Status-LED on the base unit front will flash 3 times. The App will show if the Remove device process was successful and the Status-LED on device will flash 6 times. Repeat the exclusion process from step A if it was not successful. |
NIF | Press network button once. |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Lifeline association group Include command classes: Battery report, Notification report, and Device Reset Locally notification, Binary report. |
2 | 5 | Root Device group(Binary Sensor) Binary Sensor Command Class: Compatible with 300 series 1-Binary Sensor reports status of smoke or no smoke via Lifeline. 2-When the sensor detectsstatus change between smoke and no smoke, the device will be triggered. |
3 | 5 | Root Device group(Notification) 1-Notification reports) reports the status of detect smoke or no smoke via Lifeline. 2-When the sensor detects status change between smoke and no smoke, the device will be triggered |
Dimensions | 60 x 50 x 60 mm |
Weight | 50 gr |
Hardware Platform | ZM5202 |
EAN | 4003318841507 |
IP Class | IP 20 |
Voltage | 3V |
Battery Type | 1 * CR17335 |
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Z-Wave Version | 6.71.03 |
Certification ID | ZC10-18096244 |
Z-Wave Product Id | 0x0403.0x0002.0x0003 |
Firmware Updatable | Updatable by Manufacturer |
Color | White |
Communications Protocol | Z-Wave Serial API |
Supported Notification Types | Emergency AlarmSmoke Alarm |
Frequency | Europe - 868,4 Mhz |
Maximum transmission power | 5 mW |