Dies ist ein
1) Install the battery. Visual indicator will signal the Z-Wave network adding status (green - device added, red - device not added).2) Make sure the device is located within direct range of the Z-Wave controller.3) Set the main controller in add mode (see main controllers operating manual).4) Quickly, triple click the B-button, located on FIBARO Smoke Sensor enclosure.5) FIBARO Smoke Sensor will be detected and added to the Z-Wave network.
Z-Wave ist der internationale Funkstandard zur Kommunikation von Geräten im intelligenten Haus. Dies ist ein Z-Wave Gerät und nutzt die im Quickstart angegebene Funkfrequenz.
Z-Wave ermöglicht eine sichere und stabile Kommunikation indem jede Nachricht vom Empfänger rückbestätigt wird (Zweiwege-Kommunikation) und alle netzbetriebenen Geräte Nachrichten weiterleiten (Routing) können, wenn eine direkte Funkbeziehung zwischen Sender und Empfänger gestört ist.Dank Z-Wave können Produkte unterschiedlicher Hersteller miteinander in einem Funknetz verwendet werden. Damit ist auch dieses Produkt mit beliebigen anderen Produkten anderer Hersteller in einem gemeinsamen Z-Wave Funknetz einsetzbar.
Wenn ein Gerät die spezielle sichere Kommunikation unterstützt dann wird es immer dann mit einem anderen Gerät sicher kommunizieren, wenn dieses Gerät auch eine sichere Kommunikation unterstützt. Ansonsten wird aus Kompatibilitätsgründen auf einen normalen Kommunikation umgeschaltet.
Weitere Informationen wie Produktneugkeiten, Tutorials, Supportforen etc. erhalten Sie auf www.zwave.de.
The FIBARO Smoke Sensor is a universal, ultra-light, perfectly designed, optical Z-Wave smoke detector. Fire alarm is signalled by sound, visual indicator blinking and alarm reports sent to the other devices within Z-wave network. The optical sensor detects smoke at an early stage of fire, often before flames appear and temperature starts to rise significantly. Moreover, the device has a built-in temperature sensor, which is adjustable to allow detection of fire by exceeding given temperature threshold. The FIBARO Smoke Sensor is a battery powered device designed to be placed on the wall or ceiling. Visual indicator signals fire, operating mode and it is used to check if the device is within the Z-wave network using a built-in Z-Wave range tester. The Smoke Sensor is designed to operate in confined spaces, under normal conditions (lacking of smoke, dust or condensed water vapor).Product video: https://www.youtube.com/watch?v=50QGfkdUtns
Bitte lesen Sie die Benutzeranleitung bevor Sie das Gerät in Betrieb nehmen.
Damit ein Z-Wave zu einem neuen Netz hinzugefügt werden kann muss es sich im Auslieferungs- oder Reset-Zustand befinden. Im Zweifel ist es sinnvoll, eine Exklusion durchzuführen, um das Gerät ganz sicher in diesem Zustand zu bringen. Diese Exklusion kann von jedem beliebigen Z-Wave Controller durchgeführt werden.
Dieses Gerät kann auch ohne Hilfe eines Controller in den Reset-Zustand zurückgeführt werden. Dies sollte jedoch nur dann gemacht werden wenn der Primärcontroller des Z-Wave-Netzes nicht mehr verfügbar oder defekt ist.
Please use this procedure only in the event that the system primary controller is missing or otherwise inoperable.FIBARO Smoke Sensor reset procedure:1) Make sure the device is powered.2) Press and hold the B-button for 3 seconds. Visual indicator will glow white.3) You will hear a short signal.4) Release the B-button.
Im Auslieferungszustand ist das Gerät mit keinem Z-Wave-Netz verbunden. Damit es
mit anderen Z-Wave Geräten kommunizieren kann, muss es in ein bestehendes Z-Wave Netz
eingebunden werden. Dieser Prozess wird bei Z-Wave Inklusion genannt. Geräte können
Netzwerke auch wieder verlassen. Dieser Prozess heißt bei Z-Wave Exklusion. Beide
Prozesse werden von einem Controller gestartet, der dazu in einen Inklusion- bzw.
Exklusion-Modus geschaltet werden muss. Das Handbuch des Controllers enthält
Informationen, wie er in diese Modi zu schalten ist. Erst wenn der Controller
des Z-Wave Netzes im Inclusion-Modus ist, können Geräte hinzugefügt werden.
Das Verlassen des Netzes durch Exklusion führt zum Rücksetzen dieses Gerätes
in den Auslieferungszustand.3>
Das Gerät ist batteriegespeist und damit in der Regel in einem Tiefschlafmodus um
Strom zu sparen. Im Tiefschlafmodus kann das Gerät keine Funksignale empfangen. Daher
wird ein (statischer) Controller benötigt, der netzgespeist und damit immer
funkaktiv ist. Dieser Controller - zum Beispiel ein IP-Gateway - verwaltet eine
Nachrichten-Mailbox für dieses batteriegespeiste Gerät, in dem Nachrichten an dieses
Gerät zwischengespeichert werden. Ohne einen solchen statischen Controller wird die
Nutzung dieses batteriebetriebenen Gerätes sehr schnell zur Entladung der Batterie
führen oder die Nutzung ist komplett unmöglich. Dieses Gerät weckt regelmäßig auf, meldet dies durch Aussenden einer sogenannten
Wakeup-Notifikation und leert dann seine Mailbox im statischen Controller. Dafür
muss bei der Inclusion die Node-ID des Controllers und ein Aufweckinterval
definiert werden. Erfolgt die Inklusion durch einen statischen Controller
wie zum Beispiel ein IP-Gateway, wird dieser Controller diese Konfiguration
automatisch erledigen und in der Regel eine Nutzerschnittstelle anbieten, um das
Aufweck-Interval den Nutzerbedürfnissen anzupassen. Das Aufweckinterval ist ein
Kompromiss zwischen maximaler Batterielaufzeit und minimaler Reaktionszeit des
batteriegespeisten Gerätes. Um das Gerät manuell aufzuwecken, führen Sie die folgende Aktion durch:
The Smoke Sensor will wake up at defined time interval and will ALWAYS try to communicate with the main controller.There is a possibility to wake the device up manually by triple-clicking the B-button. Inklusion
1) Install the battery. Visual indicator will signal the Z-Wave network adding status (green - device added, red - device not added).2) Make sure the device is located within direct range of the Z-Wave controller.3) Set the main controller in add mode (see main controllers operating manual).4) Quickly, triple click the B-button, located on FIBARO Smoke Sensor enclosure.5) FIBARO Smoke Sensor will be detected and added to the Z-Wave network.
Exklusion
1) Make sure there is a battery installed.2) Set the main controller in remove mode (see main controllers operating manual).3) Quickly, triple click the B-button, located on FIBARO Smoke Sensor enclosure.
Kommunikation zu einem schlafenden Gerät (Wakeup)
Die folgenden kleinen Hinweise können bei Problemen im Z-Wave Netz helfen.
Z-Wave Geräte können andere Geräte direkt steuern. Diese direkte Steuerung heißt in Z-Wave Assoziation. In den steuernden Geräten muss dazu die Geräte-ID des zu steuernden Gerätes hinterlegt werden. Dies erfolgt in sogenannten Assoziationsgruppen. Eine Assoziationsgruppe ist immer an ein Ereignis im steuernden Gerät gebunden (Tastendruck oder Auslösen eines Sensors). Bei Eintritt dieses Ereignisses wird an alle in einer Assoziationsgruppe hinterlegten Geräte ein Steuerkommando - meist ein BASIC SET - gesendet.
Gruppen-Nummer | Max. Anzahl Geräte | Beschreibung |
---|---|---|
1 | 1 | 1st groupLifeline. Reporting device state. Only one device - Z-Wave networkcontroller may be set in this group. Its not recommended to modify this associationgroup. |
2 | 5 | 2nd groupSmoke Alarm. Sending the BASIC SET control command once smoke isdetected. Its value may be modified in advanced parameters (see section XVI). Groupmay control up to five on/off devices. |
3 | 5 | 3rd groupTamper. Sending the notification NOTIFICATION REPORT (TYPE =BURGLAR, EVENT = PRODUCT COVERING REMOVED) to associated devices oncecasing opening is detected. Up to five devices supporting casing opening command(NOTIFICATION REPORT) may be included in this group. |
4 | 5 | 4th groupSmoke Alarm. Sending the notification SENSOR ALARM REPORT (TYPE= SMOKE ALARM) to associated devices once smoke is detected. Up to five devicessupporting SMOKE ALARM command may be included in this group |
5 | 5 | 5th groupTamper. Sending SENSOR ALARM REPORT notification (TYPE =GENERAL) to associated devices once casing opening is detected. Up to five devicessupporting SENSOR ALARM REPORT command may be included in this group. |
Z-Wave Produkte können direkt nach der Inklusion im Netz verwendet werden. Durch Konfigurationseinstellungen kann das Verhalten des Gerätes jedoch noch besser an die Anforderungen der Anwendung angepasst und zusätzliche Funktionen aktiviert werden.
WICHTIG: Manche Steuerungen erlauben nur die Konfiguration von vorzeichenbehafteten Werten zwischen -128 und 127. Um erforderliche Werte zwischen 128 und 255 zu programmieren, muss der gewünschte Wert minus 256 eingegeben werden. Beispiel: um einen Parameter auf einen Wert von 200 zu setzen, müsste der Wert 200-256 = -56 eingegeben werden, wenn nur positive Werte bis 128 akzeptiert werden. Bei Werten von 2 Byte Länge wird die gleiche Logik angewandt: Werte über 32768 werden als negative Werte angegeben.
There are 3 levels of sensitivity to smoke presence. Level 1 means the highestsensitivity. Rising the parameter value lowers the sensitivity to smoke presence. Grösse: 1 Byte, Voreingestellt: 2
Wert | Beschreibung |
---|---|
1 | HIGH Sensitivity |
2 | MEDIUM Sensitivity |
3 | LOW Sensitivity |
This parameter defines which frames will be sent in the 2-nd Association Group(SMOKE ALARM). The values of BASIC ON and BASIC OFF frames may bedefined as described in further parameters. Grösse: 1 Byte, Voreingestellt: 0
Wert | Beschreibung |
---|---|
0 | BASIC ON & BASIC OFF enabled |
1 | BASIC ON enabled |
2 | BASIC OFF enabled |
BASIC ON frame is sent in case of smoke presence detection and Fire Alarmtriggering. Its value is defined by the parameter. Grösse: 2 Byte, Voreingestellt: 255
Wert | Beschreibung |
---|---|
0 | turn off the device |
1 - 99 | set the device to 1-99% |
255 | set the last status |
BASIC OFF frame is sent in case of Fire Alarm cancellation. Its value is defined bythe parameter. Grösse: 2 Byte, Voreingestellt: 0
Wert | Beschreibung |
---|---|
0 | turn off the device |
1 - 99 | set the device to 1-99% |
255 | set the last status |
A value other than 0 means that alarms are being sent in broadcast mode, i.e. toall devices within a Fibaro Smoke Sensors range.NOTEOperating in Z-Wave network security mode automaticallydisables sending alarms in broadcast mode. Grösse: 1 Byte, Voreingestellt: 0
Wert | Beschreibung |
---|---|
0 | broadcast inactive |
1 | SMOKE ALARM command broadcast (2-nd & 4-th Association Group) active; casing opening notification broadcast (3-rd & 5-th Association Group) inactive |
2 | SMOKE ALARM command broadcast (2-nd & 4-th Association Group) inactive; casing opening notification broadcast (3-rd & 5-th Association Group) active |
3 | SMOKE ALARM command broadcast (2-nd & 4-th Association Group) active; casing opening notification broadcast (3-rd & 5-th Association Group) active. |
This parameter defines how commands are sent in specified association groups:as secure or non-secure. Parameter is active only in Z-Wave network securitymode. It doesnt apply to 1st Lifeline group.Parameter values may be combined, e.g. 1+2=3 means that 2nd & 3rd group aresent as secure. Grösse: 1 Byte, Voreingestellt: 15
Wert | Beschreibung |
---|---|
0 | all groups sent as non-secure |
1 | 2nd group sent as secure |
2 | 3rd group sent as secure |
4 | 4th group sent as secure |
8 | 5th group sent as secure |
This parameter allows to activate excess temperature and/or casing openingnotifications sent to the main controller.Parameter values may be combined, e.g. 1+2=3, means that all notifications areenabled. Grösse: 1 Byte, Voreingestellt: 0
Wert | Beschreibung |
---|---|
0 | all notifications disabled |
1 | casing opening notification enabled |
2 | exceeding temperature threshold notification enabled |
Time interval between consecutive temperature reports.Report is sent when new temperature value is different from the one previouslyreported - according to the set hysteresis (parameter 21). Temperature reports canbe also sent as a result of polling. Grösse: 2 Byte, Voreingestellt: 1
Wert | Beschreibung |
---|---|
0 | reports inactive |
1 - 8640 | [10s-24h] |
The temperature report will only be sent if there is a difference in temperature valuefrom the previous value reported, defined in this parameter (hysteresis).Temperature reports can be also sent as a result of polling. Grösse: 1 Byte, Voreingestellt: 10
Wert | Beschreibung |
---|---|
1 - 100 | (multiply by 0.1) |
This parameter allows to activate visual indications but does not apply to majoralarms, such as Fire, Trouble and Low battery alarm.Parameter values may be combined, e.g. 1+2+4=7, means that all notifications areenabled. Grösse: 1 Byte, Voreingestellt: 0
Wert | Beschreibung |
---|---|
0 | all notifications disabled |
1 | casing opening notification enabled |
2 | exceeding temperature threshold notification enabled |
4 | lack of Z-Wave range notification |
Temperature value measured by the built-in temperature sensor above which theexcess temperature notification is sent (visual indication/sound/Z-Wave report). Grösse: 1 Byte, Voreingestellt: 55
Wert | Beschreibung |
---|---|
1 - 100 | 1C-100C |
Time interval of signaling (visual indication/sound) excess temperature level Grösse: 2 Byte, Voreingestellt: 1
Wert | Beschreibung |
---|---|
1 - 8640 | [10s-24h] |
Time interval of signaling (visual indication/sound) lack of Z-Wave range Grösse: 2 Byte, Voreingestellt: 180
Wert | Beschreibung |
---|---|
1 - 8640 | [10s-24h] |
This parameter allows to activate sound signals but does not apply to majoralarms, such as Fire, Trouble and Low battery alarm.Parameter values may be combined, e.g. 1+2+4=7, means that all notifications areenabled. Grösse: 1 Byte, Voreingestellt: 0
Wert | Beschreibung |
---|---|
0 | all notifications disabled |
1 | casing opening notification enabled |
2 | exceeding temperature threshold notification enabled |
4 | lack of Z-Wave range notification |
Z-Wave Hardware Platform | ZM5202 |
Gerätetyp | Notification Sensor |
Netzwerkfunktion | Reporting Sleeping Slave |
Firmware Version | HW: 2 FW: 3.03:03.03 |
Z-Wave Version | 6.51.07 |
Zertifizierungs-ID | ZC10-18025999 |
Z-Wave Produkt Id | 0x010F.0x0C02.0x1003 |
Supported Notification Types | Smoke Alarm |
Color | White |
Sensors | Smoke Density |
Frequenz | XXfrequency |
Maximale Sendeleistung | XXantenna |