Dies ist ein
This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufactures and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.- Insert the two 1.5V D-Cell alkaline batteries into the battery compartment connecting the correct polarity as shown on thebattery compartment lid.- The Bellbox will emit a 2-tone beep.Put the Z-Wave gateway or control panel into Inclusion mode (please refer to the Z-Wave gateway or control panel manual).- Within 1.5 seconds, press the Function Button 3 times.- Refer to the operation manual of the Z-Wave Gateway or Control Panel to complete the adding process.- If the sensor has already been added (included) into another Z-Wave Gateway/Control Panel, or if the sensor is unable to be added intothe current Z-Wave Gateway/Control Panel, please exclude it first (see Removing Device) before attempting to include it into the current Z-Wave Gateway/Control Panel.
Z-Wave ist der internationale Funkstandard zur Kommunikation von Geräten im intelligenten Haus. Dies ist ein Z-Wave Gerät und nutzt die im Quickstart angegebene Funkfrequenz.
Z-Wave ermöglicht eine sichere und stabile Kommunikation indem jede Nachricht vom Empfänger rückbestätigt wird (Zweiwege-Kommunikation) und alle netzbetriebenen Geräte Nachrichten weiterleiten (Routing) können, wenn eine direkte Funkbeziehung zwischen Sender und Empfänger gestört ist.Dank Z-Wave können Produkte unterschiedlicher Hersteller miteinander in einem Funknetz verwendet werden. Damit ist auch dieses Produkt mit beliebigen anderen Produkten anderer Hersteller in einem gemeinsamen Z-Wave Funknetz einsetzbar.
Wenn ein Gerät die spezielle sichere Kommunikation unterstützt dann wird es immer dann mit einem anderen Gerät sicher kommunizieren, wenn dieses Gerät auch eine sichere Kommunikation unterstützt. Ansonsten wird aus Kompatibilitätsgründen auf einen normalen Kommunikation umgeschaltet.
Weitere Informationen wie Produktneugkeiten, Tutorials, Supportforen etc. erhalten Sie auf www.zwave.de.
BX-32ZW is a battery-operated wireless outdoor siren generating a loud 107 decible siren sound and strobe lights to provide visible and audible alerts for possible intruders, emergencies, and safety incidents.The multi-functional outdoor bell box can work with the Control Panel to emit entry, exit delay, and low battery beeps. The BX-32ZW generates unique alarm sounds for fire and burglary to inform users of the type of danger at hand. Its tamper-deterrent feature protects against unauthorized removal and sabotage. The BX-32ZW is compatible with other manufacturers Z-Wave alarm systems.
Bitte lesen Sie die Benutzeranleitung bevor Sie das Gerät in Betrieb nehmen.
Damit ein Z-Wave zu einem neuen Netz hinzugefügt werden kann muss es sich im Auslieferungs- oder Reset-Zustand befinden. Im Zweifel ist es sinnvoll, eine Exklusion durchzuführen, um das Gerät ganz sicher in diesem Zustand zu bringen. Diese Exklusion kann von jedem beliebigen Z-Wave Controller durchgeführt werden.
Dieses Gerät kann auch ohne Hilfe eines Controller in den Reset-Zustand zurückgeführt werden. Dies sollte jedoch nur dann gemacht werden wenn der Primärcontroller des Z-Wave-Netzes nicht mehr verfügbar oder defekt ist.
Factory Reset(Only use factory reset when network Control Panel/Gateway is missing or inoperable). - Press and hold the Function button of the Bellbox for 10 seconds tofactory reset with all LED flashes once.
Im Auslieferungszustand ist das Gerät mit keinem Z-Wave-Netz verbunden. Damit es
mit anderen Z-Wave Geräten kommunizieren kann, muss es in ein bestehendes Z-Wave Netz
eingebunden werden. Dieser Prozess wird bei Z-Wave Inklusion genannt. Geräte können
Netzwerke auch wieder verlassen. Dieser Prozess heißt bei Z-Wave Exklusion. Beide
Prozesse werden von einem Controller gestartet, der dazu in einen Inklusion- bzw.
Exklusion-Modus geschaltet werden muss. Das Handbuch des Controllers enthält
Informationen, wie er in diese Modi zu schalten ist. Erst wenn der Controller
des Z-Wave Netzes im Inclusion-Modus ist, können Geräte hinzugefügt werden.
Das Verlassen des Netzes durch Exklusion führt zum Rücksetzen dieses Gerätes
in den Auslieferungszustand.3>
Inklusion
This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufactures and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.- Insert the two 1.5V D-Cell alkaline batteries into the battery compartment connecting the correct polarity as shown on thebattery compartment lid.- The Bellbox will emit a 2-tone beep.Put the Z-Wave gateway or control panel into Inclusion mode (please refer to the Z-Wave gateway or control panel manual).- Within 1.5 seconds, press the Function Button 3 times.- Refer to the operation manual of the Z-Wave Gateway or Control Panel to complete the adding process.- If the sensor has already been added (included) into another Z-Wave Gateway/Control Panel, or if the sensor is unable to be added intothe current Z-Wave Gateway/Control Panel, please exclude it first (see Removing Device) before attempting to include it into the current Z-Wave Gateway/Control Panel.
Exklusion
The Bellbox must be removed from existing Z-Wave network before being included into another. There are two methods available to exclude a device.Exclusion Mode - Put the Z-Wave gateway or control panel into Exclusion mode(please refer to the Z-Wave gateway or control panel manual). - Within 1.5 seconds, press the Function Button 3 times and theBellbox will be removed from the Z-Wave network.
Die folgenden kleinen Hinweise können bei Problemen im Z-Wave Netz helfen.
Z-Wave Geräte können andere Geräte direkt steuern. Diese direkte Steuerung heißt in Z-Wave Assoziation. In den steuernden Geräten muss dazu die Geräte-ID des zu steuernden Gerätes hinterlegt werden. Dies erfolgt in sogenannten Assoziationsgruppen. Eine Assoziationsgruppe ist immer an ein Ereignis im steuernden Gerät gebunden (Tastendruck oder Auslösen eines Sensors). Bei Eintritt dieses Ereignisses wird an alle in einer Assoziationsgruppe hinterlegten Geräte ein Steuerkommando - meist ein BASIC SET - gesendet.
Gruppen-Nummer | Max. Anzahl Geräte | Beschreibung |
---|---|---|
1 | 1 | Group 1 for LifeLine (maximum node:1): Battery CC (COMMAND_CLASS_BATTERY) Notification CC,V4 (COMMAND_CLASS_NOTIFICATION) SwitchBinary CC, V1 (COMMAND_CLASS_SWITCH_BINARY) Device Reset Locally CC |
2 | 5 | Group 2 for Tamp rep (maximum node: 5):Notification CC,V4 (COMMAND_CLASS_NOTIFICATION)When Tamper Open, Group 2 send Notification(Type:07,Event:03), Tamper Close send Notification(Type:07,Event:00,Parameter:03) |
3 | 5 | Group 3 for AC rep (maximum node: 5):Notification CC,V4 (COMMAND_CLASS_NOTIFICATION)When AC Fail send Notification (Type:08,Event:02),When AC Restore send Notification (Type:08, Event:03) |
Z-Wave Hardware Platform | ZM5101 |
Gerätetyp | Siren |
Netzwerkfunktion | Listening Sleeping Slave |
Firmware Version | HW: 255 FW: 1.04 |
Z-Wave Version | 6.61.00 |
Zertifizierungs-ID | ZC10-17015385 |
Z-Wave Produkt Id | 0x018E.0x0002.0x000B |
Firmware Updatable | Updatable by Professional/Technician |
IP (Ingress Protection) Rated | ok |
Outdoor Use | ok |
Frequenz | XXfrequency |
Maximale Sendeleistung | XXantenna |