Quickstart

This is a secure Binary Switch DT for XXXQFrequencyName. To run this device please connect it to your mains power supply.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

META Dry Contact Switch 7 can turn ON and OFF equipments with an independent power supply, such as solenoid valves (e.g. gas, water and irrigation), power operated valves etc.In its ZRX variant the device can also be controlled by Cherubini Remote Controls of SKIPPER - POP OR GIRO series.

Reset to factory default XXXResetDescription
Inclusion XXXInclusionDescription
Exclusion XXXExclusionDescription
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 8
2 8
3 8
4 8
5 8

Configuration Parameters

Parameter 1: IN_TYPE

Define the input type. (1: button, 2: toggle switch, 0: no switch input)
Size: 1 Byte, Default Value: 1

Setting Description
0 0

Parameter 10: IN_TOGGLE

Define which event on the input toggle output. (1: 1 click , 2: 2 clicks, 4: 3 clicks, 8: Hold down, 16: Up)
Size: 1 Byte, Default Value: 15

Setting Description
0 0

Parameter 11: IN_ON_EXCLUSION

Define which input event do not switchOn output. (0: none, 1: 1 click , 2: 2 clicks, 4: 3 clicks, 8: Hold down, 16: Up)
Size: 1 Byte, Default Value: 0

Setting Description
0 0

Parameter 12: IN_OFF_EXCLUSION

Define which input event do not switchOff output. (0: none, 1: 1 click , 2: 2 clicks, 4: 3 clicks, 8: Hold down, 16: Up)
Size: 1 Byte, Default Value: 0

Setting Description
0 0

Parameter 21: OUT_TYPE

Define the output type. (0: direct load control or normally Open relay, 1: normally Closed relay)
Size: 1 Byte, Default Value: 0

Setting Description
0 0

Parameter 23: STARTUP_OUT

Define the output level on startup (0: OFF, 1: ON, 2: Previous status, 3: equal to input)
Size: 1 Byte, Default Value: 2

Setting Description
0 0

Parameter 30: TIMER_SETUP

Event that activates timer (0: none, 1: 1 click , 2: 2 clicks, 4: 3 clicks, 8: Hold down, 16: Up, 32: Net, 64: sys)
Size: 1 Byte, Default Value: 0

Setting Description
0 0

Parameter 31: OFF_TIMEOUT

Time in tenth of second after which the output will be switched Off. 0: Off timer disabled
Size: 4 Byte, Default Value: 0

Setting Description
0 0

Parameter 32: ON_TIMEOUT

Time in tenth of second after which the output will be switched On. 0: On Timer disabled
Size: 4 Byte, Default Value: 0

Setting Description
0 0

Parameter 40: G1_SETUP

Define which input event controls G1group. (0:none, 1: 1 click , 2: 2 clicks, 4: 3 clicks, 8: Hold down, 16: Up)
Size: 1 Byte, Default Value: 1

Setting Description
0 0

Parameter 41: G2_SETUP

Define which input event controls G2group. (0:none, 1: 1 click , 2: 2 clicks, 4: 3 clicks, 8: Hold down, 16: Up)
Size: 1 Byte, Default Value: 2

Setting Description
0 0

Parameter 44: G1_ASS_VALUE

The value used to control G1 association group. (0-99: specific value, 100: ON, 101: propagate, 102: toggle remote)
Size: 1 Byte, Default Value: 101

Setting Description
0 0

Parameter 45: G2_ASS_VALUE

The value used to control G2 association group. (0-99: specific value, 100: ON, 101: propagate, 102: toggle remote)
Size: 1 Byte, Default Value: 101

Setting Description
0 0

Parameter 50: DIMMING_TIME

Fade On/Off time in second used to control device in dimming group.
Size: 2 Byte, Default Value: 5

Setting Description
0 0

Parameter 51: MIN_DIM_LEVEL

Define the minimum dimming level to control device in dimming group.
Size: 1 Byte, Default Value: 1

Setting Description
0 0

Parameter 60: SCENE_SETUP

Define event sent by central scene notification. (0:none, 1:1 click , 2:2 clicks, 4:3 clicks, 8: Hold down, 16: Up)
Size: 1 Byte, Default Value: 31

Setting Description
0 0

Technical Data

Hardware Platform ZGM130S037HGN2 / ZGM130S037HGN1
Device Type Binary Switch DT
Network Operation Always On Slave
Firmware Version HW: 01 FW: 07.00
Z-Wave Version 7.16.3
Certification ID ZC14-22050108
Frequency XXfrequency
Maximum transmission power XXantenna
Binary Switch DT