This is a
Smart Dry Contact Switch 7 can turn ON and OFF equipments with an independent power supply, such as solenoid valves (e.g. gas, water and irrigation), power operated valves etc.
Reset to factory default | XXXResetDescription |
Inclusion | XXXInclusionDescription |
Exclusion | XXXExclusionDescription |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 8 | |
2 | 8 | |
3 | 8 | |
4 | 8 | |
5 | 8 |
Define the input type. (1: button, 2: toggle switch, 0: no switch input) Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | 0 |
Define which event on the input toggle output. (1: 1 click , 2: 2 clicks, 4: 3 clicks, 8: Hold down, 16: Up) Size: 1 Byte, Default Value: 15
Setting | Description |
---|---|
0 | 0 |
Define which input event do not switchOn output. (0: none, 1: 1 click , 2: 2 clicks, 4: 3 clicks, 8: Hold down, 16: Up) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | 0 |
Define which input event do not switchOff output. (0: none, 1: 1 click , 2: 2 clicks, 4: 3 clicks, 8: Hold down, 16: Up) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | 0 |
Define the output type. (0: direct load control or normally Open relay, 1: normally Closed relay) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | 0 |
Define the output level on startup (0: OFF, 1: ON, 2: Previous status, 3: equal to input) Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | 0 |
Event that activates timer (0: none, 1: 1 click , 2: 2 clicks, 4: 3 clicks, 8: Hold down, 16: Up, 32: Net, 64: sys) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | 0 |
Time in tenth of second after which the output will be switched Off. 0: Off timer disabled Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 | 0 |
Time in tenth of second after which the output will be switched On. 0: On Timer disabled Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 | 0 |
Define which input event controls G1group. (0:none, 1: 1 click , 2: 2 clicks, 4: 3 clicks, 8: Hold down, 16: Up) Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | 0 |
Define which input event controls G2group. (0:none, 1: 1 click , 2: 2 clicks, 4: 3 clicks, 8: Hold down, 16: Up) Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | 0 |
The value used to control G1 association group. (0-99: specific value, 100: ON, 101: propagate, 102: toggle remote) Size: 1 Byte, Default Value: 101
Setting | Description |
---|---|
0 | 0 |
The value used to control G2 association group. (0-99: specific value, 100: ON, 101: propagate, 102: toggle remote) Size: 1 Byte, Default Value: 101
Setting | Description |
---|---|
0 | 0 |
Fade On/Off time in second used to control device in dimming group. Size: 2 Byte, Default Value: 5
Setting | Description |
---|---|
0 | 0 |
Define the minimum dimming level to control device in dimming group. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | 0 |
Define event sent by central scene notification. (0:none, 1:1 click , 2:2 clicks, 4:3 clicks, 8: Hold down, 16: Up) Size: 1 Byte, Default Value: 31
Setting | Description |
---|---|
0 | 0 |
Hardware Platform | ZGM130S037HGN2 / ZGM130S037HGN1 |
Device Type | Binary Switch DT |
Network Operation | Always On Slave |
Firmware Version | HW: 01 FW: 07.00 |
Z-Wave Version | 7.16.3 |
Certification ID | ZC14-22040098 |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |