Quickstart

This is a secure Binary Switch DT for XXXQFrequencyName. To run this device please connect it to your mains power supply.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

Product Description

PAN44 is a Smart Energy Plug. The built-in power meter can let you monitor the power consumption of your electric appliances.The product supports an Over the Air (OTA) feature for the products firmware upgrade.

Reset to factory default XXXResetDescription
Inclusion XXXInclusionDescription
Exclusion XXXExclusionDescription
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5

Configuration Parameters

Parameter 1: Watt Meter Report Period

If the setting is configured for 1hour (set value =720), the PAN38 will report its instant power consumption every 1 hour to the node of correspond Group.The maximum interval to report its instant power consumption is 45 hours (5s*32767/3600=45hr).If the setting value is 0, the auto report function ofmeter Watt will be disabled.
Size: 2 Byte, Default Value: 720

Setting Description
0 0

Parameter 2: KWH Meter Report Period

If the setting is configured for 1hour (set value =6), the PAN38 will report its Accumulated Power Consumption (KW/h) every 1 hour to the node of correspond Group. The maximum interval to report its Accumulated Power Consumption (KW/h) is 227.55 days (10min*32767/1440=227.55 days).If the setting value is 0, the auto report function of meter KWh will be disabled.
Size: 2 Byte, Default Value: 6

Setting Description
0 0

Parameter 3: Threshold of current for Load Caution

This is a warning when the current of load over the preset threshold value, if thesetting value is 750, when the load current of Relay1 or Relay2 over this value, PAN38 will send current meter report to the node of correspond Group, the Range of the setting value is from 10 to 750, and the default value is 750.
Size: 2 Byte, Default Value: 1300

Setting Description
0 0

Parameter 4: Threshold of KWh for Load Caution

This is a warning when the KWh of load over the preset threshold value, If the setting value is 10000, when the Accumulated Power Consumption of Relay1 or Relay2 over this value, PAN38 will send KWh Meter Report command to the node of correspond Group, minimum value is 1KWh and default value is 10000 kWh.
Size: 2 Byte, Default Value: 10000

Setting Description
0 0

Parameter 5: Restore switch state mode

Whenever the AC power return from lost, PAN38 will restore the switch state which could be SWITCH OFFLAST SWITCH STATESWITCH ON. The default setting is LAST SWITCH STATE.
Size: 1 Byte, Default Value: 1

Setting Description
0 0

Parameter 6: Mode of Switch Off function

When the mode of switch On/Off is set to 0, any command of switch off will bedisabled and the Off function of include button will be disabled. The defaultsetting is enable mode. When manual On/Off function is disabled, the RF command and include button can only switch On but not Off. This is useful function for keeping the device in switch on state.
Size: 1 Byte, Default Value: 1

Setting Description
0 0

Parameter 7: LED indication mode

LED indication mode: The default setting is Show Switch State.3-7-1 Show Switch State: When switch is on, LED is on. When switch is off, LED is off. 3-7-2 Show Night mode: When switch is on, LED is off. When switch is off, LED is on.3-7-3 One Flash mode: When the state of switch changes, LED will be on only one second, then LED keeps off.
Size: 1 Byte, Default Value: 1

Setting Description
0 0

Parameter 8: Watt differential report mode

Whenever Watt value of PAN38 changes over 5% of last reading value, it will send Meter report to the group 1 nodes. However, if Watt differential mode as 0, the unsolicited report will be disabled.
Size: 1 Byte, Default Value: 1

Setting Description
0 0

Parameter 9: Switch statusreport mode

Whenever PAN38 manually switch on or off, it will send BINARY_SWITCH_ REPORT to the node of group1, disable when set to 0.
Size: 1 Byte, Default Value: 1

Setting Description
0 0

Technical Data

Hardware Platform ZGM130S037HGN2 / ZGM130S037HGN1
Device Type Binary Switch DT
Network Operation Always On Slave
Firmware Version HW: 01 FW: 01.01
Z-Wave Version 7.16.3
Certification ID ZC14-22030078
Firmware Updatable Updatable by Consumer by RF
Color White
Frequency XXfrequency
Maximum transmission power XXantenna
Binary Switch DT