PRODUCT HIGHLIGHTS:Automatic shut-off actuator for your main water valveConnect it to your Z-Wave hub for full smart home controlUse it offline with the included leak sensor probeBuilt-in temperature detection for instant freeze detectionRetrofit installation with no tools requiredUse with 1/2 - 1 1/4 ball valves only (close prior to installation)Indoor & outdoor installation with IP66 rating (avoid direct sunlight)NEW 700 series Z-Wave chip for better range and faster controlS2 Security and SmartStart for easier inclusionPRODUCT SPECS:Model Number: ZAC36Z-Wave Signal Frequency: 908.42 MHzPower: 12 V DC (1 A) power supply (included)Temperature Sensor Range: -40 to 257 FSound Indicator: up to 85 dBZ-Wave Range: Up to 400 feet line of sight (up to 130 feet indoors)Operating Temperature: 14-122 F (-10-50 C)Installation and Use: Indoor & outdoor (IP66)Standby Power Consumption: 0.12 WFull Operation Power Consumption: 8.4 W
Reset to factory default | XXXResetDescription |
Inclusion | XXXInclusionDescription |
Exclusion | XXXExclusionDescription |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | (Lifeline Group)- Device Reset Locally Notification- Basic Report- Binary Switch Report- Indicator Report- Sensor Multilevel ReportTemperature Auto report based on Configuration Parameter 0x22 Setting.- Heat Alarm Notification Report (0x04)- 0x00 = State idle- 0x02 = Overheatno location support -- 0x06 = Underheatno location support- Water Alarm Notification Report (0x05)- 0x00 = State idle- 0x02 = Water leak detectedno location support- Water Valve Notification Report (0x0F)- 0x01 = Valve operation0x00 = VALVE CLOSED/OFF (Valve does not let the water run through.)0x01 = VALVE OPEN/ON (Valve lets the water run through) |
2 | 5 | - Basic Set (By default the Configuration CC parameter 0x11 (17) Inverse Water Valve report is enabled to send out following report.)- 0x00 = Let the water run through (Based on Configuration Parameter 0x13)- 0xFF = Doesnt let the water run through. (Based on Configuration Parameter 0x12) |
3 | 5 | - Basic Set- 0x00 = IDLE / CANCEL (Based on Configuration Parameter 0x32 Setting)- 0xFF = TRIGGERED (Based on Configuration Parameter 0x31 Setting) |
4 | 5 | Basic SetAlarm- 0x00 = IDLE / CANCEL (Based on Configuration Parameter 0x27 Setting)- 0xFF = TRIGGERED (Based on Configuration Parameter 0x26 Setting) |
5 | 5 | - Basic Set- 0x00 = IDLE / CANCEL (Based on Configuration Parameter 0x2C Setting)- 0xFF = TRIGGERED (Based on Configuration Parameter 0x2B Setting) |
Decide which Z-Wave commands and reports you'd like to use to display when the device is open or closed (or to open / close the device). Default value: 1. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | reports on when the valve is open (opens the valve when an u0022onu0022 report is sent from the hub), reports off when the valve is closed (closes the valve when an u0022offu0022 report is sent from the hub) |
1 - 0 | reports off when the valve is open (opens the valve when an u0022offu0022 report is sent from the hub), reports on when the valve is closed (closes the valve when an u0022onu0022 report is sent from the hub) |
Decide which report is sent to Group 2 when parameter 17 is set to value 1 and the valve is closing. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | reports to Group 2 disabled |
1 - 0 | Basic Set on (default) |
2 - 0 | Basic Set off |
Decide which report is sent to Group 2 when parameter 17 is set to value 1 and the valve is opening. Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | reports to Group 2 disabled |
1 - 0 | Basic Set on |
2 - 0 | Basic Set off (default) |
Choose which scale you'd like the device to report temperature in. Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 | temperature reports disabled |
1 - 0 | Celsius |
2 - 0 | Fahrenheit (default) |
Set the temperature reporting threshold. Size: 2 Byte, Default Value: 260
Setting | Description |
---|---|
0 - 511 | degrees |
Set the temperature reporting offset Size: 2 Byte, Default Value: 256
Setting | Description |
---|---|
0 - 4607 | degrees |
Set the overheat alarm trigger value. Default: 104. Size: 2 Byte, Default Value: 360
Setting | Description |
---|---|
0 - 511 | degrees |
Set the overheat alarm cancellation trigger value. Default: 86. Size: 2 Byte, Default Value: 342
Setting | Description |
---|---|
0 - 511 | degrees |
Decide which report is sent to Group 4 when the overheat alarm (set in parameter 36) is triggered. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | reports to Group 4 disabled (default) |
1 - 0 | Basic Set on |
2 - 0 | Basic Set off |
Decide which report is sent to Group 4 when the overheat alarm is cancelled. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | reports to Group 4 disabled (default) |
1 - 0 | Basic Set on |
2 - 0 | Basic Set off |
Set the freeze alarm trigger value. Size: 2 Byte, Default Value: 288
Setting | Description |
---|---|
0 - 511 | degrees |
Set the freeze alarm cancellation trigger value. Default: 36. Size: 2 Byte, Default Value: 292
Setting | Description |
---|---|
0 - 511 | degrees |
Decide if you want to allow the valve actuator to open and close during freeze alarm mode. If the actuator is disabled, it won't react to Z-Wave or manual triggers to open or close until the freeze alarm is cleared. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | operation disabled |
1 - 0 | operation enabled (default) |
Decide which report is sent to Group 5 when the freeze alarm (set in parameter 40) is triggered. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | reports to Group 5 disabled (default) |
1 - 0 | Basic Set on |
2 - 0 | Basic Set off |
Decide which report is sent to Group 5 when the freeze alarm is cancelled. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | reports to Group 5 disabled (default) |
1 - 0 | Basic Set on |
2 - 0 | Basic Set off |
Decide which report is sent to Group 3 when a leak alarm is triggered (from the connected leak detection probe).Values: Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | reports to Group 3 disabled |
1 - 0 | Basic Set on (default) |
2 - 0 | Basic Set off |
Decide which report is sent to Group 3 when the leak alarm is cleared (water is no longer detected by the connected probe). Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | reports to Group 3 disabled (default) |
1 - 0 | Basic Set on |
2 - 0 | Basic Set off |
2 - 0 | Basic Set off |
2 - 0 | Basic Set off |
Decide if you want to allow the valve actuator to open and close during a leak alarm event. If the actuator is disabled, it won't react to Z-Wave or manual triggers to open or close until the leak alarm is cleared. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | operation disabled |
1 - 0 | operation enabled (default) |
Decide if you'd like to receive sound (beep) feedback when operating the actuator as well as sound alarms for different modes and alarms the actuator goes into when installed. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | sound notifications disabled |
1 - 0 | sound notifications enabled (default) |
Decide how bright you'd like the LED indicator to be on your actuator. If you set it to value 0, the LED indicator will be disabled. Default: 80. Size: 1 Byte, Default Value: 80
Setting | Description |
---|---|
0 - 99 | % |
Enable Z-Wave button lock protection if you'd like to prevent the Z-Wave button from being locked accidentally. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Z-Wave button lock disabled (default) |
1 - 0 | Z-Wave button lock enabled |
Configure Notification Report (Bitmask) Size: 1 Byte, Default Value: 13
Setting | Description |
---|---|
0 | WaterValve Open / Close Disabled / Enabled |
5 - 0 | Overheat Detection Disabled / Enabled |
10 - 0 | Freeze Detection Disabled / Enabled |
13 - 0 | All enabled |
15 - 0 | Wired Leak Probe Detection Disabled / Enabled |
Hardware Platform | ZGM130 |
Device Type | Binary Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 3 FW: 3.03 |
Z-Wave Version | 7.13.2 |
Certification ID | ZC12-22010332 |
Z-Wave Product Id | 0x027A.0x0101.0x0036 |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |